Development of Poly(aniline-co-o-toluidine)/TiO2 nanocomposite coatings for low carbon steel corrosion in 3.5% NaCl solution

2018 ◽  
Vol 32 (23) ◽  
pp. 2552-2568 ◽  
Author(s):  
Jeenat Aslam ◽  
Irfan Hussain Lone ◽  
Nagi Radwan ◽  
Mohammad Mobin ◽  
Saman Zehra ◽  
...  
MRS Advances ◽  
2017 ◽  
Vol 2 (62) ◽  
pp. 3909-3915
Author(s):  
Héctor M. Barbosa Cásarez ◽  
Araceli Espinoza Vázquez ◽  
Francisco J. Rodríguez-Gomez

AbstractPhenylcoumarin glucoside (4-PC) is a compound extracted from the plant Hintona latiflora and was studied as inhibitor for AISI 1018 steel corrosion in 3% NaCl solution using potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques, which may find application as eco-friendly corrosion inhibitors. The 4-PC provides inhibitor properties that protect AISI 1018 low carbon steel against corrosion at low concentrations (5 ppm) obtained by EIS. Polarization studies showed that the inhibitor was of mixed type. The inhibition efficiency by the two electrochemical techniques shows similar results. The inhibitor adsorption was demonstrated to be a combined process (physisorption and chemisorption) according to the Langmuir isotherm.


Author(s):  
Ya.G. Avdeev ◽  
◽  
A.V. Panova ◽  
T.E. Andreeva ◽  
Yu.I. Kuznetsov ◽  
...  

Corrosion of 08PS low-carbon steel was studied in a wide temperature range t = 25—100 °C in 1 M H2SO4 + 1 M H3PO4, 2 M H2SO4 и 2 M H3PO4, inhibited by the binary mixture IFKhAN-92 + KNCS (a molar ratio of components 9:1) and a three-component mixture IFKhAN-92 + KNCS + urotropine (9:1:400), in the presence of high concentrations of Fe(III) and Fe(II) salts, as well as in their joint presence. It is shown that under experimental conditions the corrosion inhibitors under study provide effective protection of steel in 1 M H2SO4 + 1 M H3PO4 even in the presence of Fe(III), Fe(II) salts or their mixtures. The highest protective effects are provided by a three-component inhibitor mixture. Under similar conditions in individual 2 M H3PO4 and, especially, 2 M H2SO4, the protective effects of inhibitors are lower. A stronger deceleration of steel corrosion by composite inhibitors based on IFKhAN-92 in H2SO4 + H3PO4 solutions containing Fe(III) salts in comparison with similar solutions of individual H2SO4, is largely due to the binding of Fe(III) cations by phosphate anions into complexes, that significantly reduces their chemical activity and, as a result the corrosion rate of steel.


2019 ◽  
Vol 3 (1) ◽  
pp. 263-276 ◽  
Author(s):  
Hameed B. Mahood ◽  
Asaad H. Sayer ◽  
Athraa H. Mekky ◽  
Anees A. Khadom

2013 ◽  
Vol 67 (8) ◽  
Author(s):  
Pravin Deshpande ◽  
Sanket Vathare ◽  
Shashikant Vagge ◽  
Elena Tomšík ◽  
Jaroslav Stejskal

AbstractThe coaxial coating of multi-wall carbon nanotubes (MWCNT) with poly(aniline) (PANI) was synthesised and a paint was prepared containing conducting PANI-MWCNT composite. The corrosion protection performance was assessed by open circuit potential measurements, potentiodynamic polarisation, and electrochemical impedance spectroscopy. The corrosion rate of low-carbon steel coated with 1.5 mass % of PANI-MWCNT-based paint in 3.5 mass % sodium chloride solution was found to be 0.037 mm y−1, about 5.2 times lower than that of unpainted low-carbon steel and 3.6 times lower than that of epoxy painted steel.


2018 ◽  
Vol 9 (3) ◽  
pp. 238-249 ◽  
Author(s):  
Ill-Min Chung ◽  
Venkatesan Hemapriya ◽  
Kanchana Ponnusamy ◽  
Natarajan Arunadevi ◽  
Subramanian Chitra ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document