Sterile Excimer Laser Shaped Allograft Corneal Inlay for Hyperopia: One-year Clinical Results in 28 Eyes

2021 ◽  
Vol 46 (5) ◽  
pp. 630-637
Author(s):  
Cafer Tanriverdi ◽  
Ayse Ozpinar ◽  
Sezer Haciagaoglu ◽  
Aylin Kilic
2018 ◽  
Vol 12 (1) ◽  
pp. 63-71 ◽  
Author(s):  
Muanploy Niparugs ◽  
Napaporn Tananuvat ◽  
Winai Chaidaroon ◽  
Chulaluck Tangmonkongvoragul ◽  
Somsanguan Ausayakhun

Purpose: To evaluate the efficacy, predictability, stability and safety of laser in situ keratomileusis (LASIK) using the FS200 femtosecond laser and EX500 excimer laser platform. Methods: The outcomes of 254 eyes of 129 consecutive patients with myopia or myopic astigmatism who underwent full correction femtosecond laser-assisted LASIK at CMU LASIK Center were assessed. Pre-operative and post-operative parameters including manifest refraction, Uncorrected Distance Visual Acuity (UDVA), Best Corrected Distance Visual Acuity (BDVA), corneal topography and tomography were analyzed. The results between low to moderate myopia and high myopia were compared up to 12 months. Results: Mean pre-operative Spherical Equivalent (SE) was -5.15±2.41 Diopters (D) (range -0.50 to -11.50 D) and -0.13±0.28 D, -0.13±0.27 D, -0.13±0.28 D and -0.14±0.30 D at 1, 3, 6, and 12 months, post-operatively. At 12 months, the propor¬tion of eyes achieving UDVA ≥ 20/20 was 90.0% and ≥20/40 was 98.8%. The proportion of eyes achieving post-operative mean SE ±0.5 D, and ±1 D was 91.3%, and 98.5%. No eyes lost more than two lines of BDVA. The low to moderate myopic group had a statistically significant better UDVA at one (p=0.017) and three months (p=0.014) but no difference at six (p=0.061) and 12 months (p=0.091). The mean post-operative SE was better in low to moderate myopic group at every follow-up visit (p=0.001, 0.007, <0.001 and <0.001). Conclusion: One-year clinical results of LASIK with the FS200 femtosecond laser and EX500 excimer laser showed high efficacy, predictability, stability and safety.


2010 ◽  
Vol 26 (4) ◽  
pp. 445-452 ◽  
Author(s):  
Solveiga Kelbauskiene ◽  
Nomeda Baseviciene ◽  
Kawe Goharkhay ◽  
Andreas Moritz ◽  
Vita Machiulskiene

1993 ◽  
Vol 9 (2) ◽  
Author(s):  
Ionnais G Pallikaris ◽  
Ioannia E Lambropoulos ◽  
Paul K Kolydas ◽  
Nick S Nicolopoulos ◽  
Ioannis E Kotsiras

2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Sheetal Brar ◽  
Dishitha P. Rathod ◽  
C. R. Roopashree ◽  
Sri Ganesh

Purpose. To compare clinical outcomes following LASIK for myopia performed with MEL 90 vs. Schwind Amaris 750S excimer laser. Methods. Data were collected retrospectively for patients who underwent Femto-LASIK, using the MEL 90 and Schwind Amaris 750S excimer laser for correction of myopia and myopic astigmatism within the range of −1.00 to −10.00 D SE from January 2013 till June 2018. Outcomes were analysed at 12 months for safety, efficacy, enhancement rate, and long-term complications. Results. A total of 328 eyes of 328 patients were analysed. One hundred and sixty-three eyes were treated with Schwind Amaris and the remaining 165 eyes with the MEL 90 laser. Twelve months postoperatively, the mean UDVA, CDVA, residual SE, and cylinder in the Amaris group were −0.10 ± 0.09 logMAR, −0.14 ± 0.06 logMAR, −0.21 ± 0.22 D, −0.13 ± 0.18 D versus −0.05 ± 0.07 logMAR, −0.09 ± 0.08 logMAR, −0.23 ± 0.23 D, and −0.14 ± 0.21 D for the MEL 90 group ( p values >0.05). For the Amaris group, safety and efficacy indices were 1.12 and 1.02, whereas for the MEL 90 group, these indices were 1.08 and 1.00, respectively. No eye in either group had any postop flap-related complications, infectious keratitis, diffuse lamellar keratitis, or keratectasia. Two eyes in the Amaris and 4 eyes in MEL 90 group required enhancement for the progression of myopia. Conclusion. At 12 months, both Schwind Amaris 750S and MEL 90 lasers demonstrated comparable clinical outcomes for myopic LASIK in a single surgeon setting.


2017 ◽  
Vol 11 (01) ◽  
pp. 31
Author(s):  
Jesper Hjortdal ◽  

Photorefractive keratectomy for correction of myopia was the first excimer laser-based technique to be developed. During the last 25 years, excimer lasers have improved technologically, several variations of the technique have been developed and pre- and postoperative pharmaceutical therapies have been investigated. This review article summarises these developments and the published meta-analyses on comparison of surface ablation techniques and laser in situ keratomileusis. The main conclusion is that there seem to be no differences between the clinical results obtained with the different variations of surface ablation techniques.


PEDIATRICS ◽  
1950 ◽  
Vol 5 (5) ◽  
pp. 783-790 ◽  
Author(s):  
JOHN D. CRAWFORD ◽  
MARY E. TERRY ◽  
G. MARGARET ROURKE

Observations on the relationship of administered dosage per unit of body surface area and blood concentration achieved when different amounts of sulfadiazine and acetylsalicylic acid were given patients varying widely in size indicate that a direct proportionality exists for these two drugs regardless of patient size. On the basis of this finding body surface area was used as the common denominator in the calculation of dosages of a large variety of drugs for a period of more than one year on a service dealing with patients ranging from small prematures to young adults. The clinical results suggest that this method of dosage calculation offers the advantages of simplification and greater accuracy over calculations based on a unit of body mass or on the patient's age.


2020 ◽  
Vol 12 (2) ◽  
Author(s):  
Nils Wirries ◽  
Michael Schwarze ◽  
Dorothea Daentzer ◽  
Michael Skutek

Lumbar spine disorders (LSD) might influence the outcome after total hip arthroplasty (THA). Despite a known common prevalence of LSD and degenerative hip disorders, this study investigates their mutual influence in case of co-existence with the purpose to advance surgeons planning and patient’s prognosis. Patients with and without LSD were compared before and at the one-year postoperative examination. For clinical evaluation the WOMAC was assessed. The radiological analysis focused on cup anteversion and inclination. The total group included 203 consecutive patients. The overall incidence of LSD was 51.0%. Patients with LSD were on average 4.3 years older and had a 1.8 higher BMI than non-LSD patients (P<0.05). The cup positioning and the clinical results were comparable between both groups before and at the last time of follow up (P>0.05). No hip dislocations nor clinical signs of impingement were seen.We can conclude that there is a high degree of co-existence of LSD and hip disorders. However, a strong negative impact of LSD to clinical or radiologic results could not be confirmed in our study.


2018 ◽  
Vol 32 (09) ◽  
pp. 891-896
Author(s):  
Jarosław Jabłoński ◽  
Marcin Sibiński ◽  
Michał Polguj ◽  
Jacek Kowalczewski ◽  
Dariusz Marczak ◽  
...  

AbstractThe aim of the study was to evaluate the impact of implant component alignment on objective and subjective outcomes after total knee arthroplasty (TKA). The rotation of the femoral component and its influence on the final results were also examined. After exclusion, the study examined 102 patients (mean age, 66.28 years; range, 51–79 years) who had undergone unilateral TKA. All of the operative procedures were performed by one surgeon with one type of implant. One year after the operation, improvements in Knee Society's Knee Scoring System, functional score, Western Ontario and McMaster Universities Osteoarthritis Index, and Visual Analog Scale were observed; however, none showed a significant correlation with any of the parameters analyzed by X-ray or computed tomography (CT) (α, β, γ, δ angles and posterior condylar angle [PCA]). Significant improvements were found for the vast majority of the parameters used for gate analysis at the final follow-up. Significant correlations were found between PCA angle and differences in stance phase, swing phase of the operated limb, and step width (all p = 0.03). No other significant relationships were found between gait parameters and indicators measured by X-ray and CT. None of the analyzed radiographic parameters, including rotation of the femoral component, correlated with final clinical results. Neither femoral internal rotation of 3° to 6°, nor rotation of 0° ± 3° or 0° ± 6° influenced the outcome. One year after TKA, a significant improvement was observed in both functional and gait parameters.


Sign in / Sign up

Export Citation Format

Share Document