Comparison of Three Approaches to Model Particle Penetration Coefficient through a Single Straight Crack in a Building Envelope

2010 ◽  
Vol 44 (6) ◽  
pp. 405-416 ◽  
Author(s):  
Bin Zhao ◽  
Chun Chen ◽  
Xinyan Yang ◽  
Alvin C. K. Lai
2021 ◽  
Vol 13 (13) ◽  
pp. 7382
Author(s):  
Ye Seul Eom ◽  
Bo Ram Park ◽  
Hee Won Shin ◽  
Dong Hwa Kang

We analyzed the effects of air leakage and other building characteristics on outdoor particle penetration in classrooms. The building characteristics including air leakage of 12 Korean schools were investigated, and onsite measurements were conducted to estimate the outdoor particle infiltration. The correlations among variables associated with air leakage and building characteristics and outdoor particle infiltration were analyzed using the Pearson correlation analysis and linear regression. The effective leakage area (ELA) of classrooms varied highly from 340.8–1566.9 cm2, and a significant disparity in the air leakage characteristics among the classrooms appeared. The results of onsite measurement revealed that the average ELA was larger in the corridor side with an ELAcorridor-side of 264.7 cm2 than in the outdoor side (ELAoutdoor-side of 93.1 cm2). Results of correlation analysis indicated a high correlation (r = 0.68~0.78, p-value < 0.05) between the size resolved outdoor particle source (P × λ) and specific ELA. Particularly, a strong linear relation (R2 = 0.69~0.71) with specific ELAcorridor-side was seen. Results suggest that cracks between windows and doors in the corridor side considerably affect outdoor particle penetration. These results indicate the importance of improving the airtightness of not only the building envelope but also the inter-zonal walls for effectively reducing the outdoor particle infiltration into classrooms.


2008 ◽  
Vol 6 (5/6) ◽  
pp. 534 ◽  
Author(s):  
Liwei Tian ◽  
Guoqiang Zhang ◽  
Jinghua Yu ◽  
Quan Zhang ◽  
Jin Zhou

2020 ◽  
pp. 50-64
Author(s):  
Kuladeep Kumar Sadevi ◽  
Avlokita Agrawal

With the rise in awareness of energy efficient buildings and adoption of mandatory energy conservation codes across the globe, significant change is being observed in the way the buildings are designed. With the launch of Energy Conservation Building Code (ECBC) in India, climate responsive designs and passive cooling techniques are being explored increasingly in building designs. Of all the building envelope components, roof surface has been identified as the most significant with respect to the heat gain due to the incident solar radiation on buildings, especially in tropical climatic conditions. Since ECBC specifies stringent U-Values for roof assembly, use of insulating materials is becoming popular. Along with insulation, the shading of the roof is also observed to be an important strategy for improving thermal performance of the building, especially in Warm and humid climatic conditions. This study intends to assess the impact of roof shading on building’s energy performance in comparison to that of exposed roof with insulation. A typical office building with specific geometry and schedules has been identified as base case model for this study. This building is simulated using energy modelling software ‘Design Builder’ with base case parameters as prescribed in ECBC. Further, the same building has been simulated parametrically adjusting the amount of roof insulation and roof shading simultaneously. The overall energy consumption and the envelope performance of the top floor are extracted for analysis. The results indicate that the roof shading is an effective passive cooling strategy for both naturally ventilated and air conditioned buildings in Warm and humid climates of India. It is also observed that a fully shaded roof outperforms the insulated roof as per ECBC prescription. Provision of shading over roof reduces the annual energy consumption of building in case of both insulated and uninsulated roofs. However, the impact is higher for uninsulated roofs (U-Value of 3.933 W/m2K), being 4.18% as compared to 0.59% for insulated roofs (U-Value of 0.33 W/m2K).While the general assumption is that roof insulation helps in reducing the energy consumption in tropical buildings, it is observed to be the other way when insulation is provided with roof shading. It is due to restricted heat loss during night.


2019 ◽  
pp. 10-15
Author(s):  
I.L. SHUBIN ◽  
◽  
N.P. UMNYAKOVA ◽  
I.V. MATVEEVA ◽  
K.A. ANDRIANOV ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document