Experimental Investigations on Single-Phase Shunt APF to Mitigate Current Harmonics and Switching Frequency Problems Under Distorted Supply Voltage

2018 ◽  
pp. 1-21
Author(s):  
Vijayakumar Gali ◽  
Nitin Gupta ◽  
R. A. Gupta
2020 ◽  
pp. 85-88 ◽  
Author(s):  
Nadezhda P. Kondratieva

The article describes the results of the study concerning the effect of the voltage level on current harmonic composition in greenhouses irradiators. It is found that its change affects the level of current harmonics of all types of the studied greenhouse irradiators. With decrease of nominal supply voltage by 10 %, the total harmonic distortion THDi decreases by 9 % for emitters equipped with high pressure sodium lamps (HPSL), by 10 % for emitters with electrode-less lamps and by 3 % for LED based emitters. With increase of nominal supply voltage by 10 %, THDi increases by 23 % for lighting devices equipped with HPSL, by 10 % for irradiators with electrode-less lamps and by 3 % for LED based emitters. Therefore, changes of supply voltage cause the least effect on the level of current harmonics of LED based emitters and then the emitters with electrode-less lamps. Change of the level of supply voltage causes the greatest effect on the level of current harmonics of HPSL based irradiators. Mathematical models of dependence of THDi on the level of supply voltage for greenhouse emitters equipped with LED, electrode-less lamps and HPSL lamps were formulated. These mathematical models may be used for calculations of total current when selecting transformers and supply cable lines for greenhouse lighting devices, for design of new or reconstruction of existing irradiation systems of greenhouse facilities, and for calculation of power losses in power supply networks of greenhouse facilities during feasibility studies for energy saving and energy efficiency increasing projects.


2014 ◽  
Vol 15 (2) ◽  
pp. 177-194 ◽  
Author(s):  
Anup Kumar Panda ◽  
Ranjeeta Patel

Abstract In this paper, shoot-through current elimination DC–AC converter circuit has been presented with the application of active power filter (APF). The intuitive analysis of the shoot-through in the conventional DC–AC converter has been reported first. Interleaved buck (IB) converter is adopted to eliminate the shoot-through current, thereby increasing the reliability of the interleaved buck–based active power filter (IB-APF). The 3-phase 4-wire IB-APF eliminates the current harmonics produced by the load just as a conventional one does and are innately immune to “shoot-through” phenomenon, with the elimination of special protection features required in conventional inverter circuits. A comparison has been made about the compensation capabilities of the IB-APF with the PI and fuzzy logic controller (FLC) used by id–iq control strategy under different supply voltage conditions. The id–iq control strategy used for extracting the three-phase reference current for IB-APF, evaluating their performance here in MATLAB/Simulink environment and also implemented using real-time digital simulator hardware (OPAL-RT hardware). The RTDS result verifies that the total harmonic distortion percentage of the source current can be reduced below 5% according to IEEE-519 standard recommendations on harmonic limits.


2016 ◽  
Vol 78 (10-4) ◽  
Author(s):  
Amirullah Amirullah ◽  
Mochamad Ashari ◽  
Ontoseno Penangsan ◽  
Adi Soeprijanto

Randomly installed distributed generators (DGs) in households may cause unbalanced line current in a distribution network. This research presents a battery energy system for balancing of line current in a distribution network involving multi units of single phase photovoltaic (PV) distributed generators (DGs). In this paper, the PV generators were simulated consisting of a buck-boost DC/DC converter and single phase DC/AC inverter. It was connected to the distribution line through the low voltage 220 volt 50 Hz. The proposed phase balancing system uses battery energy storage and three single phase bidirectional inverters. The inverter is capable of injecting current or absorbing power from the line to the battery. This inverter operation is arranged to balance each distribution line separately, as well as to improve other power quality parameters, such as voltage and current harmonics. Simulation results show that the system was capable of improving the unbalanced line current from 15.59 % to 11, 48 % and unbalanced line voltage from 1.76 % to 0.58 %. The system was able for increasing current harmonics from 0.98 % to 1.03% and voltage harmonics from 38.96% to 39.08%.


Energies ◽  
2018 ◽  
Vol 11 (8) ◽  
pp. 2100 ◽  
Author(s):  
Rosario Miceli ◽  
Giuseppe Schettino ◽  
Fabio Viola

In this paper, a novel approach to low order harmonic mitigation in fundamental switching frequency modulation is proposed for high power photovoltaic (PV) applications, without trying to solve the cumbersome non-linear transcendental equations. The proposed method allows for mitigation of the first-five harmonics (third, fifth, seventh, ninth, and eleventh harmonics), to reduce the complexity of the required procedure and to allocate few computational resource in the Field Programmable Gate Array (FPGA) based control board. Therefore, the voltage waveform taken into account is different respect traditional voltage waveform. The same concept, known as “voltage cancelation”, used for single-phase cascaded H-bridge inverters, has been applied at a single-phase five-level cascaded H-bridge multilevel inverter (CHBMI). Through a very basic methodology, the polynomial equations that drive the control angles were detected for a single-phase five-level CHBMI. The acquired polynomial equations were implemented in a digital system to real-time operation. The paper presents the preliminary analysis in simulation environment and its experimental validation.


2017 ◽  
Vol 14 (5) ◽  
pp. 459-466 ◽  
Author(s):  
Fiaz Ahmad ◽  
Akhtar Rasool ◽  
Esref Emre Ozsoy ◽  
Asif Sabanoviç ◽  
Meltem Elitas

Purpose This paper aims to propose a robust cascaded controller based on proportional-integral (PI) and continuous sliding mode control. Design/methodology/approach Cascaded control structure is an attractive control scheme for DC-DC power converters. It has a two-loop structure where the outer loop contains PI controller and the inner loop uses sliding mode control (SMC). This structure thus combines the merits of both the control schemes. However, there are some issues that have prohibited its adoption in industry, the discontinuous nature of SMC which leads to variable switching frequency operation and is hard to realize practically. This paper attempts to overcome this issue by changing the discontinuous functionality of SMC to continuous by utilizing the concept of equivalent control. Findings The robustness of the controller designed is verified by considering various cases, namely, ideal case with no uncertainties, sudden variation of input supply voltage, load resistance, reference voltage, circuit-parameters and for noise disturbance. The controller effectiveness is validated by simulating the DC-DC boost and Cuk converters in SimPowerSystems toolbox of MATLAB/Simulink. It is shown that the performance of the proposed controller is satisfactory, and both reference output voltage and inductor current are tracked with little or no sensitivity to disturbances. Originality/value The results for various scenarios are interesting and show that the controller works quite satisfactorily for all the simulated uncertainties.


Sign in / Sign up

Export Citation Format

Share Document