Experimental analysis of mass flow rate for partially condensed R-32 in an adiabatic straight capillary tube

2021 ◽  
pp. 1-11
Author(s):  
Maheshbhai Vanajara ◽  
Ravi Kumar ◽  
Anil Kumar
2014 ◽  
Vol 960-961 ◽  
pp. 643-647
Author(s):  
Yan Sheng Xu

A stepped capillary tube consisting of two serially connected capillary tubes with different diameters is invented to replace the conventional expansion device. The mass flow rate of refrigerant R410A in stepped capillary tubes with different size were tested. The model of stepped capillary tube is proposed, and its numerical algorithm for tube length and mass flow rate is developed. The experimental results show that the performance comparing between stepped capillary tube system and capillary tube assembly system, the cooling capacity is reduced by 0.3%, the energy efficiency ratio (EER) is equal to each other, the heating capacity is increased by 0.3%, the coefficient of performance (COP) is decreased by 0.3%. That is to say, the performance index of the two kinds of throttle mechanism is almost identical. It indicates that the stepped capillary tube can replace the capillary tube assembly in the R410A heat pump type air conditioner absolutely. The model is validated with experimental data, and the results show that the model can be used for sizing and rating stepped capillary tube.


Author(s):  
M. K. Mittal ◽  
R. Kumar ◽  
A. Gupta

The objective of this study is to investigate the effect of coiling on the flow characteristics of R-407C in an adiabatic spiral capillary tube. The characteristic coiling parameter for a spiral capillary tube is the coil pitch; hence, the effect of the coil pitch on the mass flow rate of R-407C was studied on several capillary tube test sections. It was observed that the coiling of the capillary tube significantly reduced the mass flow rate of R-407C in the adiabatic spiral capillary tube. In order to quantify the effect of coiling, the experiments were also conducted for straight a capillary tube, and it was observed that the coiling of the capillary tube reduced the mass flow rate in the spiral tube in the range of 9–18% as compared with that in the straight capillary tube. A generalized nondimensional correlation for the prediction of the mass flow rates of various refrigerants was developed for the straight capillary tube on the basis of the experimental data of R-407C of the present study, and the data of R-134a, R-22, and R-410A measured by other researchers. Additionally, a refrigerant-specific correlation for the spiral capillary was also proposed on the basis of the experimental data of R-407C of the present study.


Author(s):  
Badrish Pandey ◽  
Desireddy Shashidhar Reddy ◽  
Mohd. Kaleem Khan ◽  
Manabendra Pathak

The present research work is undertaken to develop ASHRAE like standard rating charts for currently used refrigerants R-134a and R-410A and their potential low global warming potential (GWP) substitutes R-1234yf and R-32, respectively. A self-adjustable mass prediction algorithm has been developed using an averaging technique. Based on this, a matlab code dynamically linked to refprop v. 9.0 software has been developed that solves governing equations of mass, momentum, and energy. Two-phase flow inside the capillary tube is assumed homogeneous and metastability is ignored in the proposed model. The proposed numerical models are in good agreement with the available experimental data with overall percentage mean deviation is less than 6%. Coil diameter plays an important role in adjusting the mass flow rate in the helical capillary tube. Coiling of capillary tube causes an increase in friction pressure drop and a reduction in refrigerant mass flow rate. It has been found that the mass flow rate reduces by about 5% as coil diameter is reduced from 120 to 20 mm.


2017 ◽  
Vol 25 (04) ◽  
pp. 1730004 ◽  
Author(s):  
Mehdi Rasti ◽  
Ji Hwan Jeong

Capillary tubes are widely used as expansion devices in small-capacity refrigeration systems. Since the refrigerant flow through the capillary tubes is complex, many researchers presented empirical dimensionless correlations to predict the refrigerant mass flow rate. A comprehensive review of the dimensionless correlations for the prediction of refrigerants mass flow rate through straight and coiled capillary tubes depending on their geometry and adiabatic or diabatic capillary tubes depending on the flow configurations has been discussed. A comprehensive review shows that most of previous dimensionless correlations have problems such as discontinuity at the saturated lines or ability to predict the refrigerant mass flow rate only for the capillary tube subcooled inlet condition. The correlations suggested by Rasti et al. and Rasti and Jeong appeared to be general and continuous and these correlations can be used to predict the refrigerant mass flow rate through all the types of capillary tubes with wide range of capillary tube inlet conditions including subcooled liquid, two-phase mixture, and superheated vapor conditions.


2015 ◽  
Vol 23 (02) ◽  
pp. 1550015 ◽  
Author(s):  
Ahmad Sharifian ◽  
Jeri Tangalajuk Siang

The performance of a portable propane air conditioner system, in which the temperatures of the air passing over the condenser and evaporator are equal, has been experimentally investigated under different room temperatures and refrigerant charge levels. The research has been carried out in a range of room temperatures from 20°C to 35°C and in undercharge, standard charge and overcharge conditions. The results show that, at higher room temperatures, the refrigerant temperature in all parts of the system, the density of the refrigerant at the inlet and outlet of the condenser, mass of the refrigerant in the compressor, the mass flow rate of the refrigerant and the cooling capacity of the system in either the undercharge or full charge condition, the specific cooling capacity of the undercharge system, the useful work of the compressor, and the maximum pressure of the refrigerant increase. The increase in room temperature decreases the density of the refrigerant at the inlet and outlet of the capillary tube, the mass of the refrigerant in the capillary tube, the refrigerant subcooling at the inlet of the capillary tube, the maximum velocity of the refrigerant and the coefficient of performance. In addition, the increase in room temperature at overcharge condition causes an increase in the mass flow rate, cooling capacity and specific cooling capacity to a maximum value followed by their decrease. The most important difference between a portable air conditioner and a nonportable system is the increase in cooling capacity with an increase in room temperature in full charge condition.


1996 ◽  
Vol 118 (1) ◽  
pp. 150-154 ◽  
Author(s):  
Tuncay Yilmaz ◽  
Saban U¨nal

Capillary tubes are used widely in small refrigeration systems. It is necessary to design the capillary tube, but there does not exist any analytical equation which allows the determination of capillary tube length or mass flow rate for all refrigerants. In this work, an analytical equation is derived which allows to design the capillary tubes. The comparison with existing methods and experimentally obtained values using the refrigerants R12, R22, R113, R114, R134a, and R600a has turned out to be satisfactory.


Author(s):  
Esam M Abed ◽  
Ammar A K Fathi

This study presents an experimental investigation of metastable region take place forrefrigerant flow through adiabatic and non-adiabatic capillary tube of window type airconditioner. Large numbers of experiments are carried out to explain the effect of length ofstraight and helical capillary tube on metastable region under adiabatic and non-adiabaticconditions. for the case of adiabatic capillary tube, three different length are selected(70,100 and 150) cm and two helical capillary tube, the length of each tube is 100 cm withtwo coil diameters (2 and 6) cm. For the non-adiabatic capillary tube, the straight capillarytube suction line is 150 cm while the length of non-adiabatic helical capillary tube is 200 cmwith 8 cm coil diameter. The results show that the length is the most influence parameterson beginning of metastable region. In addition the helical coil tube effect on the beginningof metastable region. As well as for the adiabatic and non-adiabatic capillary tube it isconcluded that mass flow rate is the main parameters on beginning of metastable region.Also effect of length and coiling on both pressure drop and mass flow rate are discussed.The CFD commercial code, ANSYS CFX 16.1 based on finite volume method using Kturbulencemodel considering the homogeneous flow between phases applied to straightcapillary tube. The present numerical data has been validated with the present workexperimental data and with other researchers. A good agreement is obtained which can belead to use ANSYS CFX 16.1 in the design and optimization of capillary tube in airconditioner.


2019 ◽  
Vol 27 (01) ◽  
pp. 1950001 ◽  
Author(s):  
Praveen Alok ◽  
Debjyoti Sahu

In this work, a set of computational investigation results of two-phase refrigerant flow through adiabatic capillary are presented. There are various sizes of capillary tubes that can be selected related to commercially available copper tubes. Earlier refrigerants and new refrigerants like R12, R22, R134a, R410A and R32 are used for the flow analysis. Homogeneous-equilibrium model is employed with user-defined properties of the refrigerants for computation using ANSYS CFX. Several important parameters can be predicted rapidly and accurately using this method such as refrigerant mass flow rate, vapor mass fraction, local Mach no. etc. The mean deviation in mass flow rate is found to be [Formula: see text]1.18% for the same length of capillary tube and the mean deviation of tube length is found to be [Formula: see text]1.48% for the same experimental mass flow rate with choked flow condition.


Author(s):  
Jatuporn Kaew-On ◽  
Kitti Nilpueng ◽  
Sakkarin Chingulpitak ◽  
Somchai Wongwises

In the present work, the flow phenomena of the R-134a flowing through the adiabatic capillary coiled tube are experimentally studied. The main parameters relating flow conditions such as inlet pressure, degree of subcooling mass flow rate, are examined. The test section is made from copper tubing with inner diameters of 1.07mm and the coil diameters of 50 mm. The local pressure and temperature distribution along the length of the capillary coiled tube are measured at several inlet pressures and various degrees of subcooling. The experiments are performed at inlet pressure ranging from 10 to 12 bar, mass flow rate from 9 to 11 kg/hr, and the degrees of subcooling from 6 to 10.5 °C. It was found that there are three regions of the refrigerant flow inside capillary tube including subcooled liquid region, metastable liquid region, and metastable two-phase region and these are discussed in details.