Highly sensitive optical length measurement by using a microwave photonic filter with multi-passband

2019 ◽  
Vol 66 (13) ◽  
pp. 1450-1456
Author(s):  
Jianghai Wo ◽  
Jin Zhang ◽  
Tao Wang ◽  
Pengfei Du ◽  
Anle Wang ◽  
...  
2021 ◽  
Vol 17 (10) ◽  
pp. 626-629
Author(s):  
Ailing Zhang ◽  
Jinmeng Yan ◽  
Honggang Pan ◽  
Guang Hu

2018 ◽  
Vol 186 ◽  
pp. 18-22 ◽  
Author(s):  
Takehiro Tachizaki ◽  
Toshihiko Nakata ◽  
Kaifeng Zhang ◽  
Ichiro Yamakawa ◽  
Shin-ichi Taniguchi

2014 ◽  
Vol 2 (4) ◽  
pp. B35 ◽  
Author(s):  
Ye Deng ◽  
Ming Li ◽  
Ningbo Huang ◽  
Hui Wang ◽  
Ninghua Zhu

Author(s):  
T. M. Seed ◽  
M. H. Sanderson ◽  
D. L. Gutzeit ◽  
T. E. Fritz ◽  
D. V. Tolle ◽  
...  

The developing mammalian fetus is thought to be highly sensitive to ionizing radiation. However, dose, dose-rate relationships are not well established, especially the long term effects of protracted, low-dose exposure. A previous report (1) has indicated that bred beagle bitches exposed to daily doses of 5 to 35 R 60Co gamma rays throughout gestation can produce viable, seemingly normal offspring. Puppies irradiated in utero are distinguishable from controls only by their smaller size, dental abnormalities, and, in adulthood, by their inability to bear young.We report here our preliminary microscopic evaluation of ovarian pathology in young pups continuously irradiated throughout gestation at daily (22 h/day) dose rates of either 0.4, 1.0, 2.5, or 5.0 R/day of gamma rays from an attenuated 60Co source. Pups from non-irradiated bitches served as controls. Experimental animals were evaluated clinically and hematologically (control + 5.0 R/day pups) at regular intervals.


Author(s):  
R. Y. Tsien ◽  
A. Minta ◽  
M. Poenie ◽  
J.P.Y. Kao ◽  
A. Harootunian

Recent technical advances now enable the continuous imaging of important ionic signals inside individual living cells with micron spatial resolution and subsecond time resolution. This methodology relies on the molecular engineering of indicator dyes whose fluorescence is strong and highly sensitive to ions such as Ca2+, H+, or Na+, or Mg2+. The Ca2+ indicators, exemplified by fura-2 and indo-1, derive their high affinity (Kd near 200 nM) and selectivity for Ca2+ to a versatile tetracarboxylate binding site3 modeled on and isosteric with the well known chelator EGTA. The most commonly used pH indicators are fluorescein dyes (such as BCECF) modified to adjust their pKa's and improve their retention inside cells. Na+ indicators are crown ethers with cavity sizes chosen to select Na+ over K+: Mg2+ indicators use tricarboxylate binding sites truncated from those of the Ca2+ chelators, resulting in a more compact arrangement of carboxylates to suit the smaller ion.


Author(s):  
C. Boulesteix ◽  
C. Colliex ◽  
C. Mory ◽  
B. Pardo ◽  
D. Renard

Contrast mechanisms, which are responsible of the various types of image formation, are generally thickness dependant. In the following, two imaging modes in the 100 kV CTEM are described : they are highly sensitive to thickness variations and can be used for quantitative estimations of step heights.Detailed calculations (1) of the bright-field intensity have been carried out in the 3 (or 2N+l)-beam symmetric case. They show that in given conditions, the two important symmetric Bloch waves interfere most strongly at a critical thickness for which they have equal emergent amplitudes (the more excited wave at the entrance surface is also the more absorbed). The transmitted intensity I for a Nd2O3 specimen has been calculated as a function of thickness t. The capacity of the method to detect a step and measure its height can be more clearly deduced from a plot of dl/Idt as shown in fig. 1.


Sign in / Sign up

Export Citation Format

Share Document