Effect of ground technicity on cardio-respiratory and biomechanical parameters in uphill trail running

Author(s):  
François Nicot ◽  
Frederic Sabater-Pastor ◽  
Pierre Samozino ◽  
Guillaume Y. Millet ◽  
Thomas Rupp
Author(s):  
Daniel Suter ◽  
Caio Victor Sousa ◽  
Lee Hill ◽  
Volker Scheer ◽  
Pantelis Theo Nikolaidis ◽  
...  

In recent years, there has been an increasing number of investigations analyzing the effects of sex, performance level, and age on pacing in various running disciplines. However, little is known about the impact of those factors on pacing strategies in ultramarathon trail running. This study investigated the effects of age, sex, and performance level on pacing in the UTMB® (Ultra-trail du Mont Blanc) and aimed to verify previous findings obtained in the research on other running disciplines and other ultramarathon races. Data from the UTMB® from 2008 to 2019 for 13,829 race results (12,681 men and 1148 women) were analyzed. A general linear model (two-way analysis of variance (ANOVA)) was applied to identify a sex, age group, and interaction effect in pace average and pace variation. A univariate model (one-way ANOVA) was used to identify a sex effect for age, pace average, and pace variation for the fastest men and women. In our study, pace average and a steadier pace were positively correlated. Even pacing throughout the UTMB® correlated with faster finishing times. The average pace depended significantly on sex and age group. When considering the top five athletes in each age group, sex and age group also had significant effects on pace variation. The fastest women were older than the fastest men, and the fastest men were faster than the fastest women. Women had a higher pace variation than men. In male competitors, younger age may be advantageous for a successful finish of the UTMB®. Faster male runners seemed to be younger in ultramarathon trail running with large changes in altitude when compared to other distances and terrains.


2021 ◽  
Vol 10 (9) ◽  
pp. 1905
Author(s):  
Cristina Peris-Martínez ◽  
María Amparo Díez-Ajenjo ◽  
María Carmen García-Domene ◽  
María Dolores Pinazo-Durán ◽  
María José Luque-Cobija ◽  
...  

(1) Purpose: To assess the main corneal response differences between normal and subclinical keratoconus (SCKC) with a Corvis® ST device. (2) Material and Methods: We selected 183 eyes of normal patients, of a mean age of 33 ± 9 years and 16 eyes of patients with SCKC of a similar mean age. We measured best corrected visual acuity (BCVA) and corneal topography with a Pentacam HD device to select the SCKC group. Biomechanical measurements were performed using the Corvis® ST device. We carried out a non-parametric analysis of the data with SPSS software (Wilcoxon signed rank-test). (3) Results: We found statistically significant differences between the control and SCKC groups in some corneal biomechanical parameters: first and second applanation time (p = 0.05 and p = 0.02), maximum deformation amplitude (p = 0.016), highest concavity radius (p = 0.007), and second applanation length and corneal velocity ((p = 0.039 and p = 0.016). (4) Conclusions: Our results show that the use of normalised biomechanical parameters provided by noncontact tonometry, combined with a discriminant function theory, is a useful tool for detecting subclinical keratoconus.


2021 ◽  
Vol 11 (5) ◽  
pp. 2093
Author(s):  
Noé Perrotin ◽  
Nicolas Gardan ◽  
Arnaud Lesprillier ◽  
Clément Le Goff ◽  
Jean-Marc Seigneur ◽  
...  

The recent popularity of trail running and the use of portable sensors capable of measuring many performance results have led to the growth of new fields in sports science experimentation. Trail running is a challenging sport; it usually involves running uphill, which is physically demanding and therefore requires adaptation to the running style. The main objectives of this study were initially to use three “low-cost” sensors. These low-cost sensors can be acquired by most sports practitioners or trainers. In the second step, measurements were taken in ecological conditions orderly to expose the runners to a real trail course. Furthermore, to combine the collected data to analyze the most efficient running techniques according to the typology of the terrain were taken, as well on the whole trail circuit of less than 10km. The three sensors used were (i) a Stryd sensor (Stryd Inc. Boulder CO, USA) based on an inertial measurement unit (IMU), 6 axes (3-axis gyroscope, 3-axis accelerometer) fixed on the top of the runner’s shoe, (ii) a Global Positioning System (GPS) watch and (iii) a heart belt. Twenty-eight trail runners (25 men, 3 women: average age 36 ± 8 years; height: 175.4 ± 7.2 cm; weight: 68.7 ± 8.7 kg) of different levels completed in a single race over a 8.5 km course with 490 m of positive elevation gain. This was performed with different types of terrain uphill (UH), downhill (DH), and road sections (R) at their competitive race pace. On these sections of the course, cadence (SF), step length (SL), ground contact time (GCT), flight time (FT), vertical oscillation (VO), leg stiffness (Kleg), and power (P) were measured with the Stryd. Heart rate, speed, ascent, and descent speed were measured by the heart rate belt and the GPS watch. This study showed that on a ≤10 km trail course the criteria for obtaining a better time on the loop, determined in the test, was consistency in the effort. In a high percentage of climbs (>30%), two running techniques stand out: (i) maintaining a high SF and a short SL and (ii) decreasing the SF but increasing the SL. In addition, it has been shown that in steep (>28%) and technical descents, the average SF of the runners was higher. This happened when their SL was shorter in lower steep and technically challenging descents.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yoo Jin Choo ◽  
Min Cheol Chang

AbstractWe conducted a meta-analysis to investigate the effectiveness of ankle–foot orthosis (AFO) use in improving gait biomechanical parameters such as walking speed, mobility, and kinematics in patients with stroke with gait disturbance. We searched the MEDLINE (Medical Literature Analysis and Retrieval System Online), CINAHL (Cumulative Index to Nursing and Allied Health Literature), Cochrane, Embase, and Scopus databases and retrieved studies published until June 2021. Experimental and prospective studies were included that evaluated biomechanics or kinematic parameters with or without AFO in patients with stroke. We analyzed gait biomechanical parameters, including walking speed, mobility, balance, and kinematic variables, in studies involving patients with and without AFO use. The criteria of the Cochrane Handbook for Systematic Reviews of Interventions were used to evaluate the methodological quality of the studies, and the level of evidence was evaluated using the Research Pyramid model. Funnel plot analysis and Egger’s test were performed to confirm publication bias. A total of 19 studies including 434 participants that reported on the immediate or short-term effectiveness of AFO use were included in the analysis. Significant improvements in walking speed (standardized mean difference [SMD], 0.50; 95% CI 0.34–0.66; P < 0.00001; I2, 0%), cadence (SMD, 0.42; 95% CI 0.22–0.62; P < 0.0001; I2, 0%), step length (SMD, 0.41; 95% CI 0.18–0.63; P = 0.0003; I2, 2%), stride length (SMD, 0.43; 95% CI 0.15–0.71; P = 0.003; I2, 7%), Timed up-and-go test (SMD, − 0.30; 95% CI − 0.54 to − 0.07; P = 0.01; I2, 0%), functional ambulation category (FAC) score (SMD, 1.61; 95% CI 1.19–2.02; P < 0.00001; I2, 0%), ankle sagittal plane angle at initial contact (SMD, 0.66; 95% CI 0.34–0.98; P < 0.0001; I2, 0%), and knee sagittal plane angle at toe-off (SMD, 0.39; 95% CI 0.04–0.73; P = 0.03; I2, 46%) were observed when the patients wore AFOs. Stride time, body sway, and hip sagittal plane angle at toe-off were not significantly improved (p = 0.74, p = 0.07, p = 0.07, respectively). Among these results, the FAC score showed the most significant improvement, and stride time showed the lowest improvement. AFO improves walking speed, cadence, step length, and stride length, particularly in patients with stroke. AFO is considered beneficial in enhancing gait stability and ambulatory ability.


2021 ◽  
Vol 10 (12) ◽  
pp. 2637
Author(s):  
Mª. Ángeles del Buey-Sayas ◽  
Elena Lanchares-Sancho ◽  
Pilar Campins-Falcó ◽  
María Dolores Pinazo-Durán ◽  
Cristina Peris-Martínez

Purpose: To evaluate and compare corneal hysteresis (CH), corneal resistance factor (CRF), and central corneal thickness (CCT), measurements were taken between a healthy population (controls), patients diagnosed with glaucoma (DG), and glaucoma suspect patients due to ocular hypertension (OHT), family history of glaucoma (FHG), or glaucoma-like optic discs (GLD). Additionally, Goldmann-correlated intraocular pressure (IOPg) and corneal-compensated IOP (IOPcc) were compared between the different groups of patients. Methods: In this prospective analytical-observational study, a total of 1065 patients (one eye of each) were recruited to undergo Ocular Response Analyzer (ORA) testing, ultrasound pachymetry, and clinical examination. Corneal biomechanical parameters (CH, CRF), CCT, IOPg, and IOPcc were measured in the control group (n = 574) and the other groups: DG (n = 147), FHG (n = 78), GLD (n = 90), and OHT (n = 176). We performed a variance analysis (ANOVA) for all the dependent variables according to the different diagnostic categories with multiple comparisons to identify the differences between the diagnostic categories, deeming p < 0.05 as statistically significant. Results: The mean CH in the DG group (9.69 mmHg) was significantly lower compared to controls (10.75 mmHg; mean difference 1.05, p < 0.001), FHG (10.70 mmHg; mean difference 1.00, p < 0.05), GLD (10.63 mmHg; mean difference 0.93, p < 0.05) and OHT (10.54 mmHg; mean difference 0.84, p < 0.05). No glaucoma suspects (FHG, GLD, OHT groups) presented significant differences between themselves and the control group (p = 1.00). No statistically significant differences were found in the mean CRF between DG (11.18 mmHg) and the control group (10.75 mmHg; mean difference 0.42, p = 0.40). The FHG and OHT groups showed significantly higher mean CRF values (12.32 and 12.41 mmHg, respectively) than the DG group (11.18 mmHg), with mean differences of 1.13 (p < 0.05) and 1.22 (p < 0.001), respectively. No statistically significant differences were found in CCT in the analysis between DG (562 μ) and the other groups (control = 556 μ, FHG = 576 μ, GLD = 569 μ, OHT = 570 μ). The means of IOPg and IOPcc values were higher in the DG patient and suspect groups than in the control group, with statistically significant differences in all groups (p < 0.001). Conclusion: This study presents corneal biomechanical values (CH, CRF), CCT, IOPg, and IOPcc for diagnosed glaucoma patients, three suspected glaucoma groups, and a healthy population, using the ORA. Mean CH values were markedly lower in the DG group (diagnosed with glaucoma damage) compared to the other groups. No significant difference was found in CCT between the DG and control groups. Unexpectedly, CRF showed higher values in all groups than in the control group, but the difference was only statistically significant in the suspect groups (FHG, GLD, and OHT), not in the DG group.


2017 ◽  
Vol 29 (3) ◽  
pp. 175-181 ◽  
Author(s):  
Roghiyeh Elham ◽  
Ebrahim Jafarzadehpur ◽  
Hassan Hashemi ◽  
Kazem Amanzadeh ◽  
Fereshteh Shokrollahzadeh ◽  
...  

2005 ◽  
Vol 187 (5-6) ◽  
pp. 461-472 ◽  
Author(s):  
Thomas Pufe ◽  
Bodo Kurz ◽  
Wolf Petersen ◽  
Deike Varoga ◽  
Rolf Mentlein ◽  
...  

2015 ◽  
Vol 116 (8) ◽  
pp. 1284-1289 ◽  
Author(s):  
Romain Jouffroy ◽  
Vincent Caille ◽  
Stéphane Perrot ◽  
Antoine Vieillard-Baron ◽  
Olivier Dubourg ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document