scholarly journals Progress of titanium strut for cervical reconstruction with nano-graphene oxide loaded hydroxyapatite/polyamide composite and interbody fusion after corpectomy with anterior plate fixation

2019 ◽  
Vol 47 (1) ◽  
pp. 3094-3100 ◽  
Author(s):  
Hongli Pang ◽  
Hailong Tian ◽  
Shaobo Qiu ◽  
Ning Wang ◽  
Yu-Qiang Wang
2010 ◽  
Vol 12 (4) ◽  
pp. 372-380 ◽  
Author(s):  
Dean G. Karahalios ◽  
Taro Kaibara ◽  
Randall W. Porter ◽  
Udaya K. Kakarla ◽  
Phillip M. Reyes ◽  
...  

Object An interspinous anchor (ISA) provides fixation to the lumbar spine to facilitate fusion. The biomechanical stability provided by the Aspen ISA was studied in applications utilizing an anterior lumbar interbody fusion (ALIF) construct. Methods Seven human cadaveric L3–S1 specimens were tested in the following states: 1) intact; 2) after placing an ISA at L4–5; 3) after ALIF with an ISA; 4) after ALIF with an ISA and anterior screw/plate fixation system; 5) after removing the ISA (ALIF with plate only); 6) after removing the plate (ALIF only); and 7) after applying bilateral pedicle screws and rods. Pure moments (7.5 Nm maximum) were applied in flexion and extension, lateral bending, and axial rotation while recording angular motion optoelectronically. Changes in angulation as well as foraminal height were also measured. Results All instrumentation variances except ALIF alone reduced angular range of motion (ROM) significantly from normal in all directions of loading. The ISA was most effective in limiting flexion and extension (25% of normal) and less effective in reducing lateral bending (71% of normal) and axial rotation (71% of normal). Overall, ALIF with an ISA provided stability that was statistically equivalent to ALIF with bilateral pedicle screws and rods. An ISA-augmented ALIF allowed less ROM than plate-augmented ALIF during flexion, extension, and lateral bending. Use of the ISA resulted in flexion at the index level, with a resultant increase in foraminal height. Compensatory extension at the adjacent levels prevented any significant change in overall sagittal balance. Conclusions When used with ALIF at L4–5, the ISA provides immediate rigid immobilization of the lumbar spine, allowing equivalent ROM to that of a pedicle screw/rod system, and smaller ROM than an anterior plate. When used with ALIF, the ISA may offer an alternative to anterior plate fixation or bilateral pedicle screw/rod constructs.


2020 ◽  
Vol 20 (10) ◽  
pp. 1618-1628
Author(s):  
Marc Szadkowski ◽  
Henri d'Astorg ◽  
Haroun Bouhali ◽  
Ivan Aleksic ◽  
Sonia Ramos-Pascual ◽  
...  

2007 ◽  
Vol 7 (3) ◽  
pp. 332-335 ◽  
Author(s):  
Wesley M. Johnson ◽  
Tann A. Nichols ◽  
Deepika Jethwani ◽  
Bernard H. Guiot

Object Anterior lumbar interbody fusion (ALIF) is often supplemented with instrumentation to increase stability in the spine. If anterior plate fixation provided the same stability as posterior pedicle screw fixation (PSF), then a second approach and its associated morbidity could be avoided. Methods Seven human cadaveric L4–5 spinal segments were tested under three conditions: ALIF with an anterior plate, ALIF with an anterolateral plate, and ALIF supplemented by PSF. Range of motion (ROM) was calculated for flexion/extension, lateral bending, and axial torsion and compared among the three configurations. Results There were no significant differences in ROM during flexion/extension, lateral bending, or axial torsion among any of the three instrumentation configurations. Conclusions The addition of an anterior plate or posterior PS/rod instrumentation following ALIF provides substantially equivalent biomechanical stability. Additionally, the position of the plate system, either anterior or anterolateral, does not significantly affect the stability gained.


Author(s):  
Soumitra Satapathi ◽  
Rutusmita Mishra ◽  
Manisha Chatterjee ◽  
Partha Roy ◽  
Somesh Mohapatra

Nano-materials based drug delivery modalities to specific organs and tissues has become one of the critical endeavors in pharmaceutical research. Recently, two-dimensional graphene has elicited considerable research interest because of its potential application in drug delivery systems. Here we report, the drug delivery applications of PEGylated nano-graphene oxide (nGO-PEG), complexed with a multiphoton active and anti-cancerous diarylheptanoid drug curcumin. Specifically, graphene-derivatives were used as nanovectors for the delivery of the hydrophobic anticancer drug curcumin due to its high surface area and easy surface functionalization. nGO was synthesized by modified Hummer’s method and confirmed by XRD analysis. The formation of nGO, nGO-PEG and nGO-PEG-Curcumin complex were monitored through UV-vis, IR spectroscopy. MTT assay and AO/EB staining found that nGO-PEG-Curcumin complex afforded highly potent cancer cell killing in vitro with a human breast cancer cell line MCF7.


ACS Nano ◽  
2019 ◽  
Vol 13 (8) ◽  
pp. 9482-9490 ◽  
Author(s):  
Qinwei Wei ◽  
Songfeng Pei ◽  
Guodong Wen ◽  
Kun Huang ◽  
Zhaohong Wu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document