A versatile analogue circuit based on a novel method of division

1968 ◽  
Vol 1 (12) ◽  
pp. 1217-1218
Author(s):  
D J Herrell
2014 ◽  
Vol 2014 ◽  
pp. 1-13
Author(s):  
Xin Gao ◽  
HouJun Wang ◽  
Zhen Liu

This paper proposes a novel method to estimate the influence of hard-fault in linear-analogue circuit system based on the measurement of voltage phasor with assistant branch introduced. Furthermore, a new fault diagnosis strategy based on the voltage phasor modeling is established, and the tolerance influence on the corresponding voltage measurement is also discussed. The actual analogue circuit test shows us that the proposed method is effective and reliable to locate the accurate fault signature in voltage measurement for the fault diagnosis. As a matter of fact, it includes both the amplitude and phase information in a complex value form when the linear-analogue circuit is under the AC test. Besides, it can be also applied to ambiguous groups and the sensitive test-frequencies determination in the process of fault diagnosis,while the effectiveness of multifrequencies test has also been testified through test-frequencies sweeping investigation and the maximum error evaluation of fault component value in the second circuit example.


Author(s):  
M.A. Gregory ◽  
G.P. Hadley

The insertion of implanted venous access systems for children undergoing prolonged courses of chemotherapy has become a common procedure in pediatric surgical oncology. While not permanently implanted, the devices are expected to remain functional until cure of the primary disease is assured. Despite careful patient selection and standardised insertion and access techniques, some devices fail. The most commonly encountered problems are colonisation of the device with bacteria and catheter occlusion. Both of these difficulties relate to the development of a biofilm within the port and catheter. The morphology and evolution of biofilms in indwelling vascular catheters is the subject of ongoing investigation. To date, however, such investigations have been confined to the examination of fragments of biofilm scraped or sonicated from sections of catheter. This report describes a novel method for the extraction of intact biofilms from indwelling catheters.15 children with Wilm’s tumour and who had received venous implants were studied. Catheters were removed because of infection (n=6) or electively at the end of chemotherapy.


GeroPsych ◽  
2012 ◽  
Vol 25 (4) ◽  
pp. 235-245 ◽  
Author(s):  
Katja Franke ◽  
Christian Gaser

We recently proposed a novel method that aggregates the multidimensional aging pattern across the brain to a single value. This method proved to provide stable and reliable estimates of brain aging – even across different scanners. While investigating longitudinal changes in BrainAGE in about 400 elderly subjects, we discovered that patients with Alzheimer’s disease and subjects who had converted to AD within 3 years showed accelerated brain atrophy by +6 years at baseline. An additional increase in BrainAGE accumulated to a score of about +9 years during follow-up. Accelerated brain aging was related to prospective cognitive decline and disease severity. In conclusion, the BrainAGE framework indicates discrepancies in brain aging and could thus serve as an indicator for cognitive functioning in the future.


2014 ◽  
Vol 62 (S 02) ◽  
Author(s):  
J. Photiadis ◽  
M. Musci ◽  
O. Miera ◽  
S. Ovroutski ◽  
A. Mekkawy ◽  
...  

1979 ◽  
Author(s):  
W. Nieuwenhuizen ◽  
I. A. M. van Ruijven-Vermeer ◽  
F. Haverkate ◽  
G. Timan

A novel method will be described for the preparation and purification of fibrin(ogen) degradation products in high yields. The high yields are due to two factors. on the one hand an improved preparation method in which the size heterogeneity of the degradation products D is strongly reduced by plasmin digestion at well-controlled calcium concentrations. At calcium concentrations of 2mM exclusively D fragments, M.W.= 93-000 (Dcate) were formed; in the presence of 1OmM EGTA only fragments M.W.= 80.000 (D EGTA) were formed as described. on the other hand a new purification method, which includes Sephadex G-200 filtration to purify the D:E complexes and separation of the D and E fragments by a 16 hrs. preparative isoelectric focussing. The latter step gives a complete separation of D (fragments) (pH = 6.5) and E fragments (at pH = 4.5) without any overlap, thus allowing a nearly 100% recovery in this step. The overall recoveries are around 75% of the theoretical values. These recoveries are superior to those of existing procedures. Moreover the conditions of this purification procedure are very mild and probably do not affect the native configuration of the products. Amino-terminal amino acids of human Dcate, D EGTA and D-dimer are identical i.e. val, asx and ser. in the ratgly, asx and ser were found. E 1% for rat Dcate=17-8 for rat D EGTA=16.2 and for rat D- dimer=l8.3. for the corresponding human fragments, these values were all 20.0 ± 0.2.


Sign in / Sign up

Export Citation Format

Share Document