Measurement of the single-shot pulse energy of a free electron laser using a cryogenic radiometer

Metrologia ◽  
2010 ◽  
Vol 47 (5) ◽  
pp. 518-521 ◽  
Author(s):  
Masahiro Kato ◽  
Norio Saito ◽  
Kai Tiedtke ◽  
Pavle N Juranić ◽  
Andrey A Sorokin ◽  
...  
Optica ◽  
2021 ◽  
Author(s):  
William Peters ◽  
Travis Jones ◽  
Anatoly Efimov ◽  
Emanuele Pedersoli ◽  
Laura Foglia ◽  
...  

2014 ◽  
Vol 4 (1) ◽  
Author(s):  
Felix Lehmkühler ◽  
Christian Gutt ◽  
Birgit Fischer ◽  
Martin A. Schroer ◽  
Marcin Sikorski ◽  
...  

2020 ◽  
Vol 10 (7) ◽  
pp. 2611
Author(s):  
Hirokatsu Yumoto ◽  
Yuichi Inubushi ◽  
Taito Osaka ◽  
Ichiro Inoue ◽  
Takahisa Koyama ◽  
...  

A nanofocusing optical system—referred to as 100 exa—for an X-ray free-electron laser (XFEL) was developed to generate an extremely high intensity of 100 EW/cm2 (1020 W/cm2) using total reflection mirrors. The system is based on Kirkpatrick-Baez geometry, with 250-mm-long elliptically figured mirrors optimized for the SPring-8 Angstrom Compact Free-Electron Laser (SACLA) XFEL facility. The nano-precision surface employed is coated with rhodium and offers a high reflectivity of 80%, with a photon energy of up to 12 keV, under total reflection conditions. Incident X-rays on the optics are reflected with a large spatial acceptance of over 900 μm. The focused beam is 210 nm × 120 nm (full width at half maximum) and was evaluated at a photon energy of 10 keV. The optics developed for 100 exa efficiently achieved an intensity of 1 × 1020 W/cm2 with a pulse duration of 7 fs and a pulse energy of 150 μJ (25% of the pulse energy generated at the light source). The experimental chamber, which can provide different stage arrangements and sample conditions, including vacuum environments and atmospheric-pressure helium, was set up with the focusing optics to meet the experimental requirements.


2014 ◽  
Vol 4 (1) ◽  
Author(s):  
Felix Lehmkühler ◽  
Christian Gutt ◽  
Birgit Fischer ◽  
Martin A. Schroer ◽  
Marcin Sikorski ◽  
...  

2015 ◽  
Vol 6 (1) ◽  
Author(s):  
Giovanni De Ninno ◽  
David Gauthier ◽  
Benoît Mahieu ◽  
Primož Rebernik Ribič ◽  
Enrico Allaria ◽  
...  

2015 ◽  
Vol 39 (2) ◽  
pp. 028101 ◽  
Author(s):  
Lie Feng ◽  
Hai-Xiao Deng ◽  
Tong Zhang ◽  
Chao Feng ◽  
Jian-Hui Chen ◽  
...  

2021 ◽  
Vol 28 (6) ◽  
Author(s):  
Christian David ◽  
Gediminas Seniutinas ◽  
Mikako Makita ◽  
Benedikt Rösner ◽  
Jens Rehanek ◽  
...  

The performance and parameters of the online photon single-shot spectrometer (PSSS) at the Aramis beamline of the SwissFEL free-electron laser are presented. The device operates between the photon energies 4 and 13 keV and uses diamond transmission gratings and bent Si crystals for spectral measurements on the first diffraction order of the beam. The device has an energy window of 0.7% of the median photon energy of the free-electron laser pulses and a spectral resolution (full width at half-maximum) ΔE/E on the order of 10−5. The device was characterized by comparing its performance with reference data from synchrotron sources, and a parametric study investigated other effects that could affect the reliability of the spectral information.


2018 ◽  
Vol 25 (1) ◽  
pp. 68-71 ◽  
Author(s):  
Shigeki Owada ◽  
Kyo Nakajima ◽  
Tadashi Togashi ◽  
Tetsuo Kayatama ◽  
Makina Yabashi

Arrival timing diagnostics performed at a soft X-ray free-electron laser (FEL) beamline of SACLA are described. Intense soft X-ray FEL pulses with one-dimensional focusing efficiently induce transient changes of optical reflectivity on the surface of GaAs. The arrival timing between soft X-ray FEL and optical laser pulses was successfully measured as a spatial position of the reflectivity change. The temporal resolution evaluated from the imaging system reaches ∼10 fs. This method requires only a small portion of the incident pulse energy, which enables the simultaneous operation of the arrival timing diagnostics and experiments by introducing a wavefront-splitting scheme.


Sign in / Sign up

Export Citation Format

Share Document