scholarly journals The Determination of Metronidazole and Chlorhexidine Gluconate in Metronidazole and Chlorhexidine Lotion by HPLC

2022 ◽  
Vol 2152 (1) ◽  
pp. 012016
Author(s):  
Yun Yun ◽  
Mingshi Lin

Abstract Objective “To establish an HPLC method for the determination of metronidazole and chlorhexidine gluconate in metronidazole and chlorhexidine lotion. Method Using Agilent Eclipse-XDB-C18 chromatographic column, with 0.05 mol·L-1 potassium dihydrogen phosphate solution 1000 ml plus 13.2 ml 10% tetrabutylammonium hydroxide aqueous solution (pH adjusted to 3.5 by phosphoric acid)-acetonitrile (77:23) as Mobile phase, detection wavelength 230 nm. Results The two components could be separated well. The linear ranges of metronidazole and chlorhexidine acetate were 36.33~59.04 μg·ml-1 (r = 0.9994) and 35.45~220.11 μg·ml-1 (r = 1).); The average recoveries were 100.6% and 100.5 %, and the RSD were 0.42% and 0.58%. Conclusion: The method is simple and specific, and the result is more accurate and reliable. Which is suitable for simultaneous determination of two components in compound preparations.

2013 ◽  
Vol 2013 ◽  
pp. 1-5
Author(s):  
Laura D. Simionato ◽  
Leonardo Ferello ◽  
Sebastián Stamer ◽  
Patricia D. Zubata ◽  
Adriana I. Segall

Simple, sensitive, and economical simultaneous volumetric and HPLC methods for the determination of pridinol mesylate in raw material have been developed. The volumetric method is based on the reaction of pridinol with sodium lauryl sulphate in diluted sulphuric acid. Dimethyl yellow was used as indicator to detect the end point of the titration in aqueous/organic layer. The HPLC method for the determination of pridinol mesylate employs a reverse phase C18 column at ambient temperature with a mobile phase consisting of acetonitrile: 0.05 M potassium dihydrogen phosphate, pH adjusted to 5.0 (1 : 2, v/v). The flow rate was 0.8 mL/min. Quantitation was achieved with UV detection at 258 nm based on peak area. Both methods were found to be suitable for the quality control of pridinol mesylate in raw material.


2017 ◽  
Vol 100 (4) ◽  
pp. 992-999 ◽  
Author(s):  
Ramzia I El-Bagary ◽  
Ehab F Elkady ◽  
Shereen Mowaka ◽  
Maria A Attallah

Abstract A simple, accurate, and precise LC method with a reversed stationary phase was developed and validated for the determination of perindopril (PER) arginine, amlodipine (AML), and indapamide (IND) alone and in binary mixtures (PER arginine is found in two dosage forms, i.e., with either AML or IND). Chromatographic separation was carried out on a BDS Hypersil® C18 column (100 × 3 mm, 5 μm). The mobile phase, consisting of 0.05 M potassium dihydrogen phosphate buffer (pH 2.6)–methanol (50 + 50, v/v), was pumped through the column whose temperature was maintained at 50°C at a flow rate of 0.6 mL/min using isocratic elution, and UV detection at 215 nm was performed. Acceptable values of linearity, accuracy, and precision of the method were found over the concentration ranges of 5–80 μg/mL PER, 2.5–80 μg/mL AML, and 0.5–20 μg/mL IND. The proposed chromatographic method was statistically compared to that of reference methods using one-way analysis of variance. The results showed that there was no significant difference between the methods. The developed method proved reliable for use in accurate QC of the drugs in their pharmaceutical preparations.


2020 ◽  
Vol 13 (1) ◽  
pp. 44-51
Author(s):  
S.Afreen Sultana ◽  
Patta. Salomi ◽  
T. VimalakKannan ◽  
K.Ravindra Reddy

In present study, accurate, precise, rapid and sensitive stability indicting HPLC-UV method has been established for quantification of Telmisartan, Cilnidipine and Chlorthalidone simultaneously in Tablet and bulk. Telmisartan, Cilnidipine and Chlorthalidone were resoluted on Sunsil C18 column (4.6mmx250mm; 5μm) using mobile phase containing Acetonitrile and Potassium dihydrogen phosphate in 50:50(v/v) ratio with flow rate of 1ml/min at 238 nm. Concentrations were linear over the range of 40-120 μg/ml for Telmisartan, 10-30 μg/ml for Cilnidipine and 6.25-18.75 μg/ml for Chlorthalidone. The percentage recovery was found to be 99.70-100.51% for Telmisartan, 98.41-100.49% for Cilnidipine and 99.34-100.48% for Chlorthalidone. % RSD for peak area was 0.069% for Telmisartan, 0.058% for Cilnidipine and 0.057% for Chlorthalidone shows that the proposed method is precise. Force-degradation studies have not shown any observable change in the results and hence the proposed method is stability indicating and hence the method is suitable for routine analysis of Telmisartan, Cilnidipine and Chlorthalidone in bulk and tablet dosage form.


2015 ◽  
Vol 7 ◽  
pp. 1
Author(s):  
Hani M. Hafez ◽  

Fluorometholone and Sodium Cromoglycate are used in the treatment of allergic conjunctivitis. A validated HPLC method was developed for the assay of them. The method was performed on BDS HYPERSIL C18 column (250x4.6 mm, 5μ) and the mobile phase consisted of potassium dihydrogen phosphate (pH 4.5, 0.025M) - Acetonitrile (40:60, V/V) which pumped at a flow rate 1.0 ml/min at ambient temperature. 20 µl of drugs sample solutions were monitored at two fixed wavelengths (lambda = 240.0 nm for Sodium Cromoglycate and 330.0 nm for Fluorometholone). The proposed method was validated in terms of linearity, accuracy, precision and limits of detection and quantitation according to ICH


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Zhikui Yin ◽  
Suying Ma ◽  
Jincai Wang ◽  
Xiaojun Shang

A simple, sensitive, and accurate RP-HPLC coupled with UV detector method was developed and validated for simultaneous determination of matrine and tinidazole in compound lotion. The chromatographic separation of the two compounds was carried out with a SinoChoom ODS-BP C18column (5 μm, 4.6 mm × 200 mm) analytical column, using a mobile phase consisting of 0.025 mol/L potassium dihydrogen phosphate (containing triethylamine 0.05%, v/v) and acetonitrile (80 : 20, v/v) at a flow rate of 1.0 mL/min. The detection was monitored at 210 and 310 nm for matrine and tinidazole, respectively. Total run time was 12 min, and the column was maintained at 25°C. The excipients in the compound lotion did not interfere with the drug peaks. The calibration curves of matrine and tinidazole were fairly linear over the concentration ranges of 10.0–100.0 μg/mL (r=0.9954) and 20.0–200.0 μg/mL (r=0.9968), respectively. The RSD of both the intraday and interday variations was below 1.5% for matrine and tinidazole. The proposed HPLC method was validated according to International Conference on Harmonisation and proved to be suitable for the simultaneous determination of matrine and tinidazole in compound lotion.


2012 ◽  
Vol 2012 ◽  
pp. 1-8
Author(s):  
Nesrin K. Ramadan ◽  
Afaf O. Mohamed ◽  
Sara E. Shawky ◽  
Maissa Y. Salem

Two simple, accurate, and sensitive methods were developed for the determination of netobimin in the presence of its degradation product. Method (A) was an HPLC method, performed on C18 column using acetonitrile/methanol/0.01 M potassium dihydrogen phosphate (56 : 14 : 30 by volume) as a mobile phase with a flow rate of 0.5 mL/min. Detection was performed at 254 nm. Method (B) was a TLC method, using silica gel 60 F254plates; the optimized mobile phase was toluene/methanol/chloroform/ammonium hydroxide (5 : 4 : 6 : 0.1 by volume). The spots were scanned densitometrically at 346 nm. Linearity ranges were 1–10 μg/mL for method (A) and 0.5–5 μg/band for method (B), and the mean percentage recoveries were99.3±0.7% and99.7±0.7% for methods (A) and (B), respectively. The proposed methods were found to be specific for netobimin in the presence of up to 90% of its degradation product. Statistical comparison between the results obtained by these methods and the manufacturer method was done, and no significance difference was obtained.


2021 ◽  
pp. 281-294 ◽  
Author(s):  
Abolghasem Beheshti ◽  
Zahra Kamalzadeha ◽  
Monireh Haj-Maleka ◽  
Meghdad Payaba ◽  
Mohammad Amin Rezvanfar ◽  
...  

Due to the new hopes for treatment of multiple sclerosis (MS) diseases by Teriflunomide (TFN), in this project, a cheap, robust, and fully validated method has been developed both for determination of assay content in API (active pharmaceutical ingredient), and for related impurities analysis (RIA). To operate the method, a common C18, end-capped (250 × 4.6) mm, 5µm liquid chromatography column, was applied. The mobile phase A was prepared by dissolving 2.74 g (20mM) of PDP (potassium dihydrogen phosphate) and 3.72 g (50mM) of PC (potassium chloride) in water (1000 mL). Then, pH was adjusted to 3.0 by adding OPA (ortho-phosphoric acid) 85%; while, the mobile phase B was acetonitrile (ACN) (100%). In order to confirm the experimental data about the λmax of TFN, we have used the Born-Oppenheimer molecular dynamics (BOMD) simulations, quantum mechanics (QM), and TD-DFT calculations. According to the results, the method showed a high level of suitability, specificity, linearity, accuracy, precision, repeatability, robustness, and reliable detection limit.


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (02) ◽  
pp. 44-49
Author(s):  
P Choksi ◽  
◽  
F. Shaikh ◽  
D. A. Shah ◽  
K. Agarwal ◽  
...  

A simple, specific, accurate, precise and reproducible method has been developed and validated for the estimation of bromhexine hydrochloride and enrofloxacin in fixed dose combination using RP-HPLC. The separation was achieved using stationary phase ODS Hypersil C18 column (250 mm× 4.6 mm i.d.) in isocratic mode, with mobile phase containing 0.05 M potassium dihydrogen phosphate buffer (pH 4 by o-phosphoric acid) : methanol: acetonitrile : triethylamine (40:20:40:01), at a flow rate of 1.0mL/min and eluents were monitored at 256 nm. The retention time of enrofloxacin and bromhexine HCl were found to be 3.00 min and 5.1 min respectively. The linearity for bromhexine HCl and enrofloxacin was in the range of 2-15 μg/mL and 20-150 μg/mL, respectively. The method was validated as per ICH guideline. The recoveries of bromhexine HCl and enrofloxacin were found in the range of 99.61-101.65% and 99.52-100.13 %, respectively. The method was successfully applied for the determination of both the drugs in combined dosage form.


2015 ◽  
Vol 98 (6) ◽  
pp. 1496-1502 ◽  
Author(s):  
Ramzia I El-Bagary ◽  
Ehab F Elkady ◽  
Shereen Mowaka ◽  
Maria Attallah

Abstract Two simple, accurate, and precise chromatographic methods have been developed and validated for the determination of dronedarone (DRO) HCl and amiodarone (AMI) HCl either alone or in binary mixtures due to the possibility of using AMI as a counterfeit of DRO because of its lower price. First, an RP-HPLC method is described for the simultaneous determination of DRO and AMI. Chromatographic separation was achieved on a BDS Hypersil C18 column (150 × 4.6 mm, 5 μm). Isocratic elution based on potassium dihydrogen phosphate buffer with 0.1% triethylamine pH 6–methanol (10 + 90, v/v) at a flow rate of 2 mL/min with UV detection at 254 nm was performed. The second method is RP ultra-HPLC in which the chromatographic separation was achieved on an AcclaimTM RSLC 120 C18 column (100 × 2.1 mm, 2.2 μm) using isocratic elution with potassium dihydrogen phosphate buffer with 0.1% triethylamine pH 6–methanol (5 + 95, v/v) at a flow rate of 1 mL/min with UV detection at 254 nm. Linearity, accuracy, and precision of the two methods were found to be acceptable over the concentration ranges of 5–80 μg/mL for both DRO and AMI. The results were statistically compared using one-way analysis of variance. The optimized methods were validated and proved to be specific, robust, precise, and accurate for the QC of the drugs in their pharmaceutical preparations.


Sign in / Sign up

Export Citation Format

Share Document