scholarly journals Limited-angle TOF-PET for intraoperative surgical applications: proof of concept and first experimental data

2022 ◽  
Vol 17 (01) ◽  
pp. T01002
Author(s):  
S. Sajedi ◽  
L. Bläckberg ◽  
S. Majewski ◽  
H. Sabet

Abstract The intraoperative gamma probe (IPG) based on single gamma-ray detection remains the current gold standard modality for sentinel lymph node identification and tumor removal in cancer patients. However, IPGs do not meet the <5% false negative rate (FNR) requirement, a key metric suggested by the American Society of Clinical Oncology (ASCO). We aim to reduce FNR by using time of flight (TOF) PET detector technology in limited angle geometry system by using only two detector panels in coincidence. For proof of concept, we used two Hamamatsu TOF PET detector modules (C13500-4075YC-12) featuring 12× 12 arrays of 4.14× 4.14× 20 mm3 LFS crystal pixels with 4.2 mm pitch and coupled one-one to silicon photomultiplier (SiPM) pixels. The measured detector coincidence timing resolution (CTR) was 271 ps FWHM for the whole detector. We 3D printed lesion phantom containing spheres 2–10 mm in diameter, representing lymph nodes, and placed it inside a 10-liter warm background water phantom. Experimental results showed that with subminute data acquisition, 6 mm diameter spheres could be identified in the image when a lesion phantom with a 10:1 activity ratio to background was used. The simulation results were in good agreement with the experimental data by resolving 6 mm diameter spherical lesions with a 60 second acquisition time in a 25 cm deep background water phantom with a 10:1 activity ratio. As expected, the image quality improved as the CTR improved in the simulation and with decreasing background water phantom depth or increasing lesion-to-background activity ratio in the experiment. With the results presented here, we concluded that using a limited angle TOF PET detector system is a major step forward for intraoperative applications in that lesion detectability is beyond what conventional gamma- and NIR-based probes could achieve.

2007 ◽  
Vol 17 (1) ◽  
pp. 147-153 ◽  
Author(s):  
Lukas Rob ◽  
Helena Robova ◽  
Marek Pluta ◽  
Pavel Strnad ◽  
Josef Kacirek ◽  
...  

We studied the distribution of sentinel lymph nodes (SLNs) in vulvar cancer using blue dye and 99mTc radiocolloid and evaluated the techniques used, including the optimum timing of preoperative scintigraphy scans and its contribution to 99mTc SLN detection over that of the intraoperative handheld gamma probe. Fifty-nine women with squamous cell cancers <4 cm treated at our institution between December 2001 and December 2005 were included in this study. Blue dye alone was used in the first 16 women (group A) and the combination of 99mTc and blue dye was used on 43 women (group B). Of the 118 SLN detected in 82 groins, 83.9% (99) were sited in the superficial medial and intermediate inguinal chain, none were in superficial lateral groin, 16.1% (19) were deep femoral. The patient-specific SLN detection and false-negative rate in group B was 100% and 0%, compared to 68.8% (11/16 cases) and 6.3% (1/16) in group A. The optimum timing for preoperative lymphoscintigraphy scans was 45 min postinjection, but intraoperative use of the handheld gamma probe yielded 15% more “hot” nodes and allowed tailored placement of the lymphadenectomy incision. Eighty-four percent of SLNs were in the medial and intermediate region of the superficial inguinal chain, 16.1% were deep femoral. The combined use of 99mTc radiocolloid and blue dye was significantly superior at SLN detection than blue dye alone. 99mTc SLN detection using the intraoperative handheld probes was not enhanced by preoperative scintigraphy scans.


Methodology ◽  
2019 ◽  
Vol 15 (3) ◽  
pp. 97-105
Author(s):  
Rodrigo Ferrer ◽  
Antonio Pardo

Abstract. In a recent paper, Ferrer and Pardo (2014) tested several distribution-based methods designed to assess when test scores obtained before and after an intervention reflect a statistically reliable change. However, we still do not know how these methods perform from the point of view of false negatives. For this purpose, we have simulated change scenarios (different effect sizes in a pre-post-test design) with distributions of different shapes and with different sample sizes. For each simulated scenario, we generated 1,000 samples. In each sample, we recorded the false-negative rate of the five distribution-based methods with the best performance from the point of view of the false positives. Our results have revealed unacceptable rates of false negatives even with effects of very large size, starting from 31.8% in an optimistic scenario (effect size of 2.0 and a normal distribution) to 99.9% in the worst scenario (effect size of 0.2 and a highly skewed distribution). Therefore, our results suggest that the widely used distribution-based methods must be applied with caution in a clinical context, because they need huge effect sizes to detect a true change. However, we made some considerations regarding the effect size and the cut-off points commonly used which allow us to be more precise in our estimates.


Author(s):  
Brian M. Katt ◽  
Casey Imbergamo ◽  
Fortunato Padua ◽  
Joseph Leider ◽  
Daniel Fletcher ◽  
...  

Abstract Introduction There is a known false negative rate when using electrodiagnostic studies (EDS) to diagnose carpal tunnel syndrome (CTS). This can pose a management dilemma for patients with signs and symptoms that correlate with CTS but normal EDS. While corticosteroid injection into the carpal tunnel has been used in this setting for diagnostic purposes, there is little data in the literature supporting this practice. The purpose of this study is to evaluate the prognostic value of a carpal tunnel corticosteroid injection in patients with a normal electrodiagnostic study but exhibiting signs and symptoms suggestive of carpal tunnel, who proceed with a carpal tunnel release. Materials and Methods The group included 34 patients presenting to an academic orthopedic practice over the years 2010 to 2019 who had negative EDS, a carpal tunnel corticosteroid injection, and a carpal tunnel release. One patient (2.9%), where the response to the corticosteroid injection was not documented, was excluded from the study, yielding a study cohort of 33 patients. Three patients had bilateral disease, yielding 36 hands for evaluation. Statistical analysis was performed using Chi-square analysis for nonparametric data. Results Thirty-two hands (88.9%) demonstrated complete or partial relief of neuropathic symptoms after the corticosteroid injection, while four (11.1%) did not experience any improvement. Thirty-one hands (86.1%) had symptom improvement following surgery, compared with five (13.9%) which did not. Of the 32 hands that demonstrated relief following the injection, 29 hands (90.6%) improved after surgery. Of the four hands that did not demonstrate relief after the injection, two (50%) improved after surgery. This difference was statistically significant (p = 0.03). Conclusion Patients diagnosed with a high index of suspicion for CTS do well with operative intervention despite a normal electrodiagnostic test if they have had a positive response to a preoperative injection. The injection can provide reassurance to both the patient and surgeon before proceeding to surgery. Although patients with a normal electrodiagnostic test and no response to cortisone can still do well with surgical intervention, the surgeon should carefully review both the history and physical examination as surgical success may decrease when both diagnostic tests are negative. Performing a corticosteroid injection is an additional diagnostic tool to consider in the management of patients with CTS and normal electrodiagnostic testing.


2020 ◽  
Vol 22 (1) ◽  
pp. 25-29
Author(s):  
Zubayer Ahmad ◽  
Mohammad Ali ◽  
Kazi lsrat Jahan ◽  
ABM Khurshid Alam ◽  
G M Morshed

Background: Biliary disease is one of the most common surgical problems encountered all over the world. Ultrasound is widely accepted for the diagnosis of biliary system disease. However, it is a highly operator dependent imaging modality and its diagnostic success is also influenced by the situation, such as non-fasting, obesity, intestinal gas. Objective: To compare the ultrasonographic findings with the peroperative findings in biliary surgery. Methods: This prospective study was conducted in General Hospital, comilla between the periods of July 2006 to June 2008 among 300 patients with biliary diseases for which operative treatment is planned. Comparison between sonographic findings with operative findings was performed. Results: Right hypochondriac pain and jaundice were two significant symptoms (93% and 15%). Right hypochondriac tenderness, jaundice and palpable gallbladder were most valuable physical findings (respectively, 40%, 15% and 5%). Out of 252 ultrasonically positive gallbladder, stone were confirmed in 249 cases preoperatively. Sensitivity of USG in diagnosis of gallstone disease was 100%. There was, however, 25% false positive rate detection. Specificity was, however, 75% in this case. USG could demonstrate stone in common bile duct in only 12 out of 30 cases. Sensitivity of the test in diagnosing common bile duct stone was 40%, false negative rate 60%. In the series, ultrasonography sensitivity was 100% in diagnosing stone in cystic duct. USG could detect with relatively good but less sensitivity the presence of chronic cholecystitis (92.3%) and worm inside gallbladder (50%). Conclusion: Ultrasonography is the most important investigation in the diagnosis of biliary disease and a useful test for patients undergoing operative management for planning and anticipating technical difficulties. Journal of Surgical Sciences (2018) Vol. 22 (1): 25-29


2020 ◽  
Vol 35 (Supplement_3) ◽  
Author(s):  
Joachim Beige ◽  
Ralph Wendt ◽  
Despina Rüssmann ◽  
Karl-Peter Ringel

Abstract Background and Aims Incompatibility of dialysis procedure due to hypersensitivity against dialyzer material which currently is mainly based on polysulfone and derivatives can not be assessed by routine laboratory tests. Although the frequency of such symptoms is suspected to be low (below 2%) such resembles an important clinical problem because dialysis procedures are frequently accompanied by symptoms of non-tolerability with reasons not being entirely clear while circulatory reasons are suspected to play a major role. Method To enlighten the role of polysulfone hypersensitivity, we adapted known standardized material immune-toxicological tests (lymphocyte transformation test, basophil degranulation test) to the specific conditions of dialysis and polysulfone material sensitivity. We developed a method of polysulfone micronisation and measured humoral immune response of isolated patient´s lymphocytes when incubated with polysulfone dispersion. Results 39 samples from 103 patients with suspected polysulfone hypersensitivity showed positive results for type 1 (n=19), type 4 (n=18) or both type (n=2) reactions. There were no significant differences in the level of stimulation measured for DI, SI and lymphogenesis before and after dialysis (average delta -0.4; -0.28; - 1.74, p = 0.71; 0.34; 0.37) and with different dialyzer materials (Tab. 1). Patients with pos. type 4 results (LTT and lymphogenesis) showed highly correlated results in either LTT or lymphogenesis test (Fig. 1, R=0.87, p&lt;0.0001). 8 out of 8 samples from patients with repeated test on different PS showed positive results on either PS. One patient tested positive on PS showed no hypersensitivity with another non-PS (PMMA) material. Conclusion This is the first methodological report showing plausible in-vitro results of patients samples concerning polysulfone intolerance. On the first superficial view, a “false-negative” rate of 60% looks rather disappointing, because all samples derived from patients with suspicion of PS hypersensitivity. However, due to the clinical variability of intolerance symptoms and the high prevalence of any problems after HD initiation, mainly of circulatory origin after initiating extracorporeal circuit, this rate may obviously express the true frequency of isolated PS material hypersensitivity in suspected patients. Alternative pathophysiological pathways of material sensitivity like complement activation, remain to be elucidated and incorporated into a comprehensive future testing panel. Further clinical and laboratory research is needed to define true polysulfone hypersensitivity and to enlighten the field of hypothetic subclinical material incompatibility in patients with impaired dialysis tolerability.


2019 ◽  
Vol 6 (1) ◽  
Author(s):  
Michel Hesse ◽  
Stephan Walrand

AbstractVolumes of usual PET phantoms are about four to sixfold that of a human liver. In order to avoid count rate saturation and handling of very high 90Y activity, reported TOF-PET phantom studies are performed using specific activities lower than those observed in liver radioembolization.However, due to the constant random coincidence rate induced by the natural crystal radioactivity, reduction of 90Y specific activity in TOF-PET imaging cannot be counterbalanced by increasing the acquisition time. As a result, most 90Y phantom studies reported images noisier than those obtained in whole-body 18F-FDG, and thus advised to use dedicated noise control in TOF-PET imaging post 90Y liver radioembolization.We performed acquisitions of the Jaszczak Deluxe phantom in which the hot rod insert was only partially filled with 2.6 GBq of 90Y. Standard reconstruction parameters recommended by the manufacturer for whole-body 18F-FDG PET were used.Low specific activity setups, although exactly compensated by increasing the acquisition time in order to get the same number of detected true coincidences per millilitre, were impacted by significant noise. On the other hand, specific activity and acquisition time setup similar to that used in post 90Y liver radioembolization provided image quality very close to that of whole-body 18F-FDG.This result clearly discards the use of low specific activity phantoms intended to TOF-PET reconstruction parameter optimization. Volume reduction of large phantoms can be achieved by vertically setting the phantoms or by adding Styrofoam inserts.


2021 ◽  
Vol 10 (7) ◽  
pp. 1543
Author(s):  
Morwenn Le Boulc’h ◽  
Julia Gilhodes ◽  
Zara Steinmeyer ◽  
Sébastien Molière ◽  
Carole Mathelin

Background: This systematic review aimed at comparing performances of ultrasonography (US), magnetic resonance imaging (MRI), and fluorodeoxyglucose positron emission tomography (PET) for axillary staging, with a focus on micro- or micrometastases. Methods: A search for relevant studies published between January 2002 and March 2018 was conducted in MEDLINE database. Study quality was assessed using the QUality Assessment of Diagnostic Accuracy Studies checklist. Sensitivity and specificity were meta-analyzed using a bivariate random effects approach; Results: Across 62 studies (n = 10,374 patients), sensitivity and specificity to detect metastatic ALN were, respectively, 51% (95% CI: 43–59%) and 100% (95% CI: 99–100%) for US, 83% (95% CI: 72–91%) and 85% (95% CI: 72–92%) for MRI, and 49% (95% CI: 39–59%) and 94% (95% CI: 91–96%) for PET. Interestingly, US detects a significant proportion of macrometastases (false negative rate was 0.28 (0.22, 0.34) for more than 2 metastatic ALN and 0.96 (0.86, 0.99) for micrometastases). In contrast, PET tends to detect a significant proportion of micrometastases (true positive rate = 0.41 (0.29, 0.54)). Data are not available for MRI. Conclusions: In comparison with MRI and PET Fluorodeoxyglucose (FDG), US is an effective technique for axillary triage, especially to detect high metastatic burden without upstaging majority of micrometastases.


2011 ◽  
Vol 21 (9) ◽  
pp. 1679-1683 ◽  
Author(s):  
Tessa A. Ennik ◽  
David G. Allen ◽  
Ruud L.M. Bekkers ◽  
Simon E. Hyde ◽  
Peter T. Grant

BackgroundThere is a growing interest to apply the sentinel node (SN) procedure in the treatment of vulvar cancer. Previous vulvar surgery might disrupt lymphatic patterns and thereby decrease SN detection rates, lengthen scintigraphic appearance time (SAT), and increase SN false-negative rate. The aims of this study were to evaluate the SN detection rates at the Mercy Hospital for Women in Melbourne and to investigate whether previous vulvar surgery affects SN detection rates, SAT, and SN false-negative rate.MethodsData on all patients with vulvar cancer who underwent an SN procedure (blue dye, technetium, or combined technique) from November 2000 to July 2010 were retrospectively collected.ResultsSixty-five SN procedures were performed. Overall detection rate was 94% per person and 80% per groin. Detection rates in the group of patients who underwent previous excision of the primary tumor were not lower compared with the group without previous surgery or with just an incisional biopsy. There was no statistical significant difference in SAT between the previous excision group and the other patients. None of the patients with a false-negative SN had undergone previous excision.ConclusionsResults indicate that previous excision of a primary vulvar malignancy does not decrease SN detection rates or increase SN false-negative rate. Therefore, the SN procedure appears to be a reliable technique in patients who have previously undergone vulvar surgery. Previous excision did not significantly lengthen SAT, but the sample size in this subgroup analysis was small.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Katherine F. Jarvis ◽  
Joshua B. Kelley

AbstractColleges and other organizations are considering testing plans to return to operation as the COVID-19 pandemic continues. Pre-symptomatic spread and high false negative rates for testing may make it difficult to stop viral spread. Here, we develop a stochastic agent-based model of COVID-19 in a university sized population, considering the dynamics of both viral load and false negative rate of tests on the ability of testing to combat viral spread. Reported dynamics of SARS-CoV-2 can lead to an apparent false negative rate from ~ 17 to ~ 48%. Nonuniform distributions of viral load and false negative rate lead to higher requirements for frequency and fraction of population tested in order to bring the apparent Reproduction number (Rt) below 1. Thus, it is important to consider non-uniform dynamics of viral spread and false negative rate in order to model effective testing plans.


Sign in / Sign up

Export Citation Format

Share Document