scholarly journals 2D electrical resistivity imaging to determine depth of andesite spreading at Tanjung Batu, Jambi as eco-friendly exploration of minerals method

2021 ◽  
Vol 926 (1) ◽  
pp. 012046
Author(s):  
T Kusmita ◽  
Iwalzi

Abstract Tanjung Batu has potential subsurface minerals in the form of Andesite rocks. Andesite can be used appropriately for infrastructure with excellent physical features, including hardness, compressive strength, density, as well as the water and weather resistance level. Andesite is one type of igneous rock that is widely used in the construction sector, especially infrastructure such as roads, bridges, housing, airports, and seaports. In mining, the depth of mineral exploration usually using borehole method. In this study used electrical resistivity method with dipole-dipole configurations. Electrical resistivity is also capable for identifying Andesite rocks in subsurface without drilling the area because each rock has a different rock resistivity value. In this study used 240 meters of track and 20 meters space of electrodes. Based on 2D Imaging, range of Andesite resistivity in this area was 170 - >1095 Ωm. Andesite depth was at 3.42, 10.6, 18.5 and - 27.2 m.

2016 ◽  
Vol 33 (3) ◽  
Author(s):  
Eduardo M.S. Amarante ◽  
Olivar A.L. de Lima ◽  
Susana S. Cavalcanti

ABSTRACT. To investigate the subsurface geological and hydrological conditions around the area of the Alagoinhas county cemetery – Bahia State, Brazil, 38 vertical electrical soundings using Schlumberger electrode array were performed to a maximum AB/2 spacing... RESUMO. Para investigar as condições geológicas e hidrológicas da subsuperfície na área do entorno do Cemitério Municipal de Alagoinhas, Bahia, foram realizadas 38 sondagens elétricas verticais centradas em pontos acessíveis da área. As sondagens foram...


2020 ◽  
Vol 7 ◽  
pp. 19
Author(s):  
Joseph Olakunle Coker ◽  
Akindamola Julius Agbelemoge ◽  
Stephen Oluwafemi Ariyo ◽  
Victor Makinde ◽  
Aderemi Amidu Alabi ◽  
...  

Groundwater is described as the water found beneath the surface of the earth in underground streams and aquifers and has become popular as a source of drinking potable water in Nigeria due to its quality when compared to other water sources. The Electrical resistivity method was employed in Imakun Omi Community, a coastal town in Ogun Waterside Local government area of  Ogun State with the aim of determining the groundwater potential of the area. A total of twenty (20) Vertical Electrical Soundings (VES) points were carried out in the area using the Schlumberger configuration with maximum current electrode separation (AB) of 300m using the ABEM SAS 1000 Terrameter. The results obtained were interpreted quantitatively and qualitatively using partial curve matching and computer iteration programs WINRESIST and SURFER 11 for the interpretation from which the reflection coefficient was computed. The groundwater potential of the rock units were evaluated and  40% of the stations show  high yield, 50% of the stations show medium yield and 10% of the stations was observed to have low yield. The aquifer thicknesses are very thick with values ranging from 6.9 m to 79.3 m, hence an average of 43.1mand overburden thicknesses ranging from 9.7m to 96.5 m, with an average of 53.1m


2021 ◽  
Vol 5 (1) ◽  
pp. 18
Author(s):  
Matthew Tersoo Tsepav ◽  
Aliyu Yahaya Badeggi ◽  
Obaje Nuhu George ◽  
Usman Yusuf Tanko ◽  
Ibrahim Samuel Ibbi

<p>Electrical resistivity method employing the Schlumberger array was used to occupy forty four (44) vertical electrical sounding points in Lapai town with the aim of determining the depth to aquifers, aquifer thicknesses and aquifer protective capacity. The G41 Geotron resistivity meter was used in obtaining the apparent resistivity data which was processed using Interpex 1XD resistivity interpretation software. The results revealed four lithologic sections which include top lateritic soil, sandy clay, fractured basement and fresh basement. Both confined and unconfined aquifers were identified within the area, with four classes of aquifer proactive capacities as high, moderate, weak and poor. While the aquifer at VES 20 was highly protected, twenty other aquifers were moderately protected, eight others had weak protection and fifteen aquifers were poorly protected. The aquifers were generally of good thicknesses and at varying reasonable depths, making them good reservoirs of water in appreciable quantity. The average aquifer thickness was estimated to be 48.36m while the average depth to aquifers was estimated to be 56.68m.</p>


2016 ◽  
Vol 34 (4) ◽  
Author(s):  
Antonio Carlos de Siqueira Neto ◽  
Vagner Roberto Elis

ABSTRACT. The electrical resistivity method (ER) with the electrical profiling technique (EP) were applied to landfill Delta A, located next to the highway dos Bandeirantes in Campinas (SP). Within the landfill there is a region of approximately 5,200 m2...Keywords: electrical resistivity, landfill, experimental cell. RESUMO. O método de eletrorresistividade (ER) utilizando a técnica de caminhamento elétrico (CE) foi aplicado no aterro Delta A, localizado ao lado da rodovia dos Bandeirantes nomunicípio de Campinas (SP). Dentro do aterro há uma região de...Palavras-chave: resistividade elétrica, aterro sanitário, célula experimental.


Author(s):  
Dian Darisma ◽  
Ferdy Fernanda ◽  
Muhammad Syukri

Lam Apeng is a village with a majority of people living as farmers, which causes the need of water for agriculture is increasing. The water demand in this area continues to increase as the population increases, for various purposes. The objective of this study is to determine the distribution of the groundwater layer using the electrical resistivity method and to determine groundwater potential using hydraulic parameters. This research is conducted using 2 measurement line with a length of each line is 112 meters and distances of each electrode is 2 meters. The data invert using Res2Dinv software to obtain 2D subsurface lithology subsurface. At line 1, the aquifer (sand) layer is located in the second layer with a rock resistivity value of 12 Ωm - 18.6 Ωm at a depth of 8 m - 18 m. At line 2, the aquifer (sand) layer is also located in the second layer with a resistivity value of 4.6 Ωm - 18 Ωm at a depth of 5 m – 12 m. Based on the interpretation of the two measurement lines, it can be concluded that the type of aquifer in the research site is a semi unconfined aquifer. In this study, hydraulic parameters (hydraulic conductivity, longitudinal conductance, transverse resistance, and transmissivity) was calculated based on the resistivity value and the thickness of the aquifer layer. The average resistivity of the aquifer layer used is 15.3 Ωm and 11.3 Ωm, respectively for line 1 and line 2, indicating that the aquifer was moderately corrosive. Longitudinal conductance values are 0.65 Ω-1 and 0.62 Ω-1 which indicated moderate protective capacity. The transmissivity values are 6.78 m2/dayand 4.77 m2/day, which indicates that the designation in this area is low and the groundwater potential is local or only for personal consumption.


Sign in / Sign up

Export Citation Format

Share Document