scholarly journals Deformation of high performance concrete plate under humid tropical weather

Author(s):  
C Niken ◽  
T Elly ◽  
FX Supartono ◽  
I Laksmi
2021 ◽  
Vol 7 (2) ◽  
pp. 63-73
Author(s):  
Niken Chatarina ◽  

The relationship between surrounding temperature and deformation behaviour of one full scale concrete plate with compressive strength of 60 MPa was presented in this paper. This research was done in Indonesia. Indonesia presents humid tropical weather. A specimen measuring 3.00m × 1.60m × 0.15m was used. Deformation was obtained by using four embedded vibrating wire strain gauges. The range observation is held between 7 to 28 days. The peaks of deformation follow peaks of surrounding temperature. Some deformation peaks time occur after surrounding temperature peak time, it is called as delay time. As a result, there is a linear relationship between temperature and deformation. The relationship was influenced by a factor which presented its position and delay time. The average error of this model is less than 15% at the age range of 7 until 14 days, and less than 50% at the age range of 15 - 28 days.


PCI Journal ◽  
2001 ◽  
Vol 46 (1) ◽  
pp. 79-81
Author(s):  
John J. Roller ◽  
Robert N. Bruce ◽  
Henry G. Russell

PCI Journal ◽  
2020 ◽  
Vol 65 (6) ◽  
pp. 35-61
Author(s):  
Chungwook Sim ◽  
Maher Tadros ◽  
David Gee ◽  
Micheal Asaad

Ultra-high-performance concrete (UHPC) is a special concrete mixture with outstanding mechanical and durability characteristics. It is a mixture of portland cement, supplementary cementitious materials, sand, and high-strength, high-aspect-ratio microfibers. In this paper, the authors propose flexural design guidelines for precast, prestressed concrete members made with concrete mixtures developed by precasters to meet minimum specific characteristics qualifying it to be called PCI-UHPC. Minimum specified cylinder strength is 10 ksi (69 MPa) at prestress release and 18 ksi (124 MPa) at the time the member is placed in service, typically 28 days. Minimum flexural cracking and tensile strengths of 1.5 and 2 ksi (10 and 14 MPa), respectively, according to ASTM C1609 testing specifications are required. In addition, strain-hardening and ductility requirements are specified. Tensile properties are shown to be more important for structural optimization than cylinder strength. Both building and bridge products are considered because the paper is focused on capacity rather than demand. Both service limit state and strength limit state are covered. When the contribution of fibers to capacity should be included and when they may be ignored is shown. It is further shown that the traditional equivalent rectangular stress block in compression can still be used to produce satisfactory results in prestressed concrete members. A spreadsheet workbook is offered online as a design tool. It is valid for multilayers of concrete of different strengths, rows of reinforcing bars of different grades, and prestressing strands. It produces moment-curvature diagrams and flexural capacity at ultimate strain. A fully worked-out example of a 250 ft (76.2 m) span decked I-beam of optimized shape is given.


PCI Journal ◽  
2008 ◽  
Vol 53 (4) ◽  
pp. 108-130
Author(s):  
Mohsen A. Issa ◽  
Atef A. Khalil ◽  
Shahidul Islam ◽  
Paul D. Krauss

Sign in / Sign up

Export Citation Format

Share Document