The Activated Plasma Recalcification Time: A Measurement Encompassing the Activated Partial Thromboplastin Time and Platelet Function, with Improved Detection of Bleeders

1975 ◽  
Vol 64 (1) ◽  
pp. 80-86
Author(s):  
Ronald C. Vura ◽  
Carl E. Speicher
2017 ◽  
Vol 32 (5) ◽  
pp. 638-647 ◽  
Author(s):  
Manisha Buriuli ◽  
Wasupalli Geeta Kumari ◽  
Devendra Verma

The aim of this work was to develop a polyelectrolyte complex-based hemostatic dressing made from chitosan and polygalacturonic acid. Porous dressings were fabricated by ultrasonication of chitosan and alginate solutions followed by freeze-drying. Since chitosan has inherent hemostatic properties, and polygalacturonic acid is anti-inflammatory in nature, it was desired to combine these two polymers to develop an effective hemostatic dressing, which may also promote wound healing. Porous structure of the bandages was observed using field-emission scanning electron microscope. Blood clotting behavior was studied using whole blood clotting assay. Plasma recalcification time, prothrombin time, and activated partial thromboplastin time were also determined to study the mechanism of clotting. The dressings were found to accelerate clotting rates and showed increased thrombin activity with an increase in chitosan concentration.


2021 ◽  
Vol 8 (9) ◽  
pp. 210462
Author(s):  
Bingxian Lin ◽  
Kaiming Liu ◽  
Yunren Qiu

Polysulfone (PSF) works potentially in haemodialysis due to its great mechanical and chemical stability, but performs poorly in haemocompatibility. For promoting the unpleasant haemocompatibility, sulfonated citric chitosan (SCACS) with the structure and groups similar to heparin was primarily synthesized by acylation and sulfonation. Furthermore, the chloroacylated PSF was pretreated by electrophilic chloroacetyl chloride to achieve more active sites for further reaction; the following membranes underwent the amination and were named amination polysulfone (AMPSF) membranes. Moreover, SCACS with abundant carboxyl and sulfonic groups was covalently grafted at the surface of pretreated PSF membranes, called PSF-SCACS membranes. The PSF-SCACS membranes were successfully synthesized and characterized by 1 H NMR, ATR-FTIR and XPS. In addition, the water contact angle of PSF-SCACS membranes decreased by 47° and the morphologies of the membranes changed little compared with the unmodified PSF membranes. The haemocompatible testing results, including protein adsorption, platelet adhesion, haemolysis rate, plasma recalcification time, activated partial thromboplastin time (APTT), prothrombin time (PT) and thrombin time (TT), demonstrated that the PSF-SCACS membranes possessed excellent haemocompatible performances, and SCACS played an important role in the modification.


1982 ◽  
Vol 47 (02) ◽  
pp. 177-181 ◽  
Author(s):  
Ingebrigt Talstad

SummaryProblems by using whole blood (WB) of various packed cell volume (PCV) in heparin measurements were studied. WB had to be used within 1 hr, due to influence of platelet Factor 4. The increase of Ca++ by increasing PCV, had a moderate influence by the assays studied. The recalcification time (RT) of WB was timeconsuming and had low accuracy and precision, due to different heparin response. The activated partial thromboplastin time (APTT) also had low accuracy and precision, due to different heparin response; the results were equal for WB and plasma. The thrombin clotting time (TCT) had high accuracy and precision in plasma. The TCT could also be used for WB since there was a good correlation between T20 (20 NTH U thrombin/ml) using WB, and T30 using plasma (r = 0.89, N = 61). The calcium thrombin clotting time (CaTCT) is not recommended for WB assaying.


1990 ◽  
Vol 63 (01) ◽  
pp. 016-023 ◽  
Author(s):  
A M H P van den Bessekaar ◽  
J Meeuwisse-Braun ◽  
R M Bertina

SummaryFive different APTT reagents, two amidolytic anti-ITa assays, one amidoiytic anti-Xa assay, and one coagulometric anti-Xa/ anti-IIa assay were used to assess the effect of heparin in patients treated for venous thromboembolic disease. Good correlations were observed between lug-transformed APYE> determined with the various reagents (correlation coefficients: 0.92-0.96).Nevertheless there were important differences in the slopes of the lines of relationship between the APTT reagents.Good correlations were observed between the anti-Xa and anti-IIa assay results (correlation coefficients: 0.92-0.97). However, the amidolytic anti-Xa activity was significantly higher (p <0.001) than the two amidolytic anti-IIa activities. Less good correlations were observed between the log-transformed APTTs and the anti-Xa or anti-IIa activities (correlation coefficients: 0.64-0.78). The correlations were improved by transforming the APTT into APTT-ratio, i.e. the ratio of the patient’s APTT to the same patient’s APTT after removal of heparin from the plasma sample by means of ECTEOLA-cellulose treatment. The correlation coefficients of log (AFTT-ratio) with anti-Xa or anti-IIa ranged from 0.76 to 0.87.For both APTT and amidolytic heparin assay, the response to in vitro heparin was different from the response to ex vivo heparin.Therefore, equivalent therapeutic ranges should be assessed by using ex vivo samples rather than in vitro heparin. Because of the response differences between the APTT reagents, it is not adequate to define a therapeutic range for heparin therapy without specification of the reagent.


1994 ◽  
Vol 72 (05) ◽  
pp. 685-692 ◽  
Author(s):  
Michael T Nurmohamed ◽  
René J Berckmans ◽  
Willy M Morriën-Salomons ◽  
Fenny Berends ◽  
Daan W Hommes ◽  
...  

SummaryBackground. Recombinant hirudin (RH) is a new anticoagulant for prophylaxis and treatment of venous and arterial thrombosis. To which extent the activated partial thromboplastin time (APTT) is suitable for monitoring of RH has not been properly evaluated. Recently, a capillary whole blood device was developed for bed-side monitoring of the APTT and it was demonstrated that this device was suitable to monitor heparin therapy. However, monitoring of RH was not evaluated.Study Objectives. To evaluate in vitro and ex vivo the responsiveness and reproducibility for hirudin monitoring of the whole blood monitor and of plasma APTT assays, which were performed with several reagents and two conventional coagulometers.Results. Large interindividual differences in hirudin responsiveness were noted in both the in vitro and the ex vivo experiments. The relationship between the APTT, expressed as clotting time or ratio of initial and prolonged APTT, and the hirudin concentration was nonlinear. A 1.5-fold increase of the clotting times was obtained at 150-200 ng/ml plasma. However, only a 2-fold increase was obtained at hirudin levels varying from 300 ng to more than 750 ng RH/ml plasma regardless of the assays. The relationship linearized upon logarithmic conversion of the ratio and the hirudin concentration. Disregarding the interindividual differences, and presuming full linearity of the relationship, all combinations were equally responsive to hirudin.Conclusions. All assays were equally responsive to hirudin. Levels up to 300 ng/ml plasma can be reliably estimated with each assay. The manual device may be preferable in situations where rapid availability of test results is necessary.


1979 ◽  
Vol 42 (05) ◽  
pp. 1355-1367 ◽  
Author(s):  
C V Prowse ◽  
A Chirnside ◽  
R A Elton

SummaryVarious factor IX concentrates have been examined in a number of in vitro tests of thrombogenicity. The results suggest that some tests are superfluous as in concentrates with activity in any of these tests activation is revealed by a combination of the non-activated partial thromboplastin time, the thrombin (or Xa) generation time and factor VIII inhibitor bypassing activity tests. Assay of individual coagulant enzymes revealed that most concentrates contained more factor IXa than Xa. However only a small number of concentrates, chiefly those that had been purposefully activated, contained appreciable amounts of either enzyme.


1985 ◽  
Vol 53 (01) ◽  
pp. 116-117 ◽  
Author(s):  
R E Merton ◽  
A D Curtis ◽  
D P Thomas

SummaryHeparin samples from five manufacturers were assayed by the revised British Pharmacopoeia (BP) heparin assay and the results compared with those obtained using the activated partial thromboplastin time (APTT) assay. The United States Pharmacopeia (USP) reference heparin preparation and the 4th International Standard (IS) for heparin were also assayed by the two methods relative to the 3rd IS. The results obtained by the revised BP assay were in close agreement with those obtained by the APTT assay for all the heparins that were tested. The assays revealed that there is at least a 10% discrepancy between the International Unit for heparin and the USP unit.


Author(s):  
Э.М. Гаглоева ◽  
В.Б. Брин ◽  
С.В. Скупневский ◽  
Н.В. Боциева ◽  
Т.В. Молдован

Цель исследования - изучить состояние системы гемостаза при хронической интоксикации хлоридом никеля, исследовать взаимосвязь показателей гемокоагуляции с процессами липопероксидации у крыс в эксперименте. Методика. Опыты проводили на крысах-самцах Вистар (n=50, 230-250 г). Раствор NiCl2 (5 мг/кг) вводили внутрижелудочно ежедневно в течение 2 нед, 1 и 2 мес. По завершении эксперимента исследовали состояние тромбоцитарного и коагуляционного звеньев гемостаза, антикоагулянтную и фибринолитическую активность крови, а также определяли активность процессов перекисного окисления липидов и антиоксидантных ферментов. Результаты. Установлено, что через 2 нед и 1 мес интоксикации у крыс отмечались гиперкоагуляционные изменения показателей свертывающей системы крови: повышение агрегационной активности тромбоцитов, увеличение концентрации фибриногена, снижение активированного частичного тромбопластинового времени (АЧТВ) и протромбинового времени. В этот период регистрировалось увеличение антитромбиновой и фибринолитической активности крови. Через 2 мес наблюдалось подавление активности клеточного звена гемостаза - тромбоцитопения, ослабление степени АДФ-индуцируемой агрегации тромбоцитов. Выявлялась тенденция к уменьшению концентрации фибриногена. На фоне снижения АЧТВ и тромбинового времени отмечалось увеличение протромбинового времени. В то же время регистрировалось угнетение противосвертывающего звена системы гемостаза (снижалась активность антитромбина III), наблюдалось истощение резервных возможностей фибринолитического звена (замедление фXIIа-зависимого эуглобулинового лизиса) и увеличение содержания растворимых фибрин мономерных комплексов, что свидетельствует о наличии тромбинемии. Через 2 нед, один и два месяца интоксикации у животных выявлялись корреляционные связи между основными показателями системы гемостаза и активностью процессов перекисного окисления липидов и антиоксидантных ферментов. Заключение. Полученные данные подтверждают наличие взаимосвязи активности процессов липопероксидации и системы гемостаза, в том числе при хронической никелевой интоксикации. Результаты исследования позволяют рекомендовать применение антиоксидантов для разработки способов коррекции гемостатических сдвигов при воздействии на организм тяжелых металлов. The aim. To study the state of the hemostasis system in chronic nickel intoxication and to investigate the relationship between hemocoagulation indices and lipoperoxidation processes in rats. Methods. Experiments were carried out on male Wistar rats (n=50, 230-250 g). A solution of nickel chloride (5 mg/kg) was administered daily intragastrically for two weeks, one and two months. At the end of the experiments, indices of platelet and coagulation hemostasis systems, anticoagulant and fibrinolytic activity of blood plasma, and activities of lipid peroxidation and antioxidant enzymes were studied. Results. Hypercoagulative changes in indices of the coagulation system were observed in rats after two weeks and one month of intoxication, including increased platelet aggregation and fibrinogen concentration and shortened activated partial thromboplastin time and prothrombin time. During the same period, increased antithrombin and fibrinolytic activities were observed. The depressed activity of the cellular component of hemostasis evident as thrombocytopenia and impaired ADP-induced platelet aggregation was detected after two months of intoxication. A tendency to decrease in fibrinogen concentration was observed. The shortened activated partial thromboplastin time and thrombin time were associated with prolonged prothrombin time. At the same time, inhibition of the anticoagulant component of hemostasis (decreased antithrombin III activity), exhaustion of the fibrinolysis system reserve (delayed fXIIa-dependent euglobulin lysis), and a significant increase in soluble fibrin monomeric complexes indicative of thrombinemia were observed. After two weeks, one and two months of nickel intoxication, a correlation was found between the major indices of the hemostasis system and the activities of lipid peroxidation and antioxidant enzymes. Conclusion. The study confirmed a relationship between the lipid peroxidation activity and the hemostasis system, specifically in chronic nickel intoxication. This result allows to recommend the use of antioxidants in developing methods for correction of hemostatic induced affected by heavy metals.


Sign in / Sign up

Export Citation Format

Share Document