Relationship Between Histopathologic Typing and Morphonuclear Assessments of 238 Thyroid Lesions: Digital Cell Image Analysis Performed on Feulgen-Stained Nuclei from Formalin-Fixed, Paraffin-Embedded Materials

1992 ◽  
Vol 97 (6) ◽  
pp. 776-786 ◽  
Author(s):  
Isabelle Salmon ◽  
Plinio Gasperin ◽  
Jean-Lambert Pasteels ◽  
Rodolphe Heimann ◽  
Robert Kiss
2011 ◽  
Vol 135 (7) ◽  
pp. 896-902
Author(s):  
Aziza Nassar ◽  
Cynthia Cohen ◽  
Sally S. Agersborg ◽  
Weidong Zhou ◽  
Kathleen A. Lynch ◽  
...  

Abstract Context.—Aperio Technologies, Inc (Vista, California) provides a new immunohistochemistry (IHC) HER2 Image Analysis (IA) system that allows tuning of the intensity thresholds of the HER2/neu scoring scheme to adapt to the staining characteristics of different reagents. Objective.—To compare the trainable IHC HER2 IA system for different reagents to conventional manual microscopy (MM) in a multisite study. Design.—Two hundred sixty formalin-fixed, paraffin-embedded breast cancer specimens from 3 clinical sites were assayed: 180 specimens stained with Dako's HercepTest (Carpinteria, California), and 80 specimens stained with Ventana's PATHWAY HER-2/neu (Tucson, California). At each site, 3 pathologists performed a blinded reading of the glass slides with the use of a light microscope. The glass slides were then scanned and after a wash-out period and randomization, the same pathologists outlined a representative set of tumor regions to be analyzed by IHC HER2 IA. Each of the methods, MM and IA, was evaluated separately and comparatively by using κ statistics of negative HER2/neu scores (0, 1+) versus equivocal HER2/neu scores (2+) versus positive HER2/neu scores (3+) among the different pathologists. Results.—κ Values for IA and MM were obtained across all sites. MM: 0.565–0.864; IA: 0.895–0.947; MM versus IA: 0.683–0.892 for site 1; MM: 0.771–0.837; IA: 0.726–0.917; MM versus IA: 0.687–0.877 for site 2; MM: 0.463–0.674; IA: 0.864–0.918; MM versus IA: 0.497–0.626 for site 3. Conclusion.—Aperio's trainable IHC HER2 IA system shows substantial equivalence to MM for Dako's HercepTest and Ventana's PATHWAY HER-2/neu at 3 clinical sites. Image analysis improved interpathologist agreement in the different clinical sites.


2021 ◽  
Vol 123 (6) ◽  
pp. 151765
Author(s):  
Arthur E. Morley-Bunker ◽  
George A.R. Wiggins ◽  
Margaret J. Currie ◽  
Helen R. Morrin ◽  
Martin R. Whitehead ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document