scholarly journals Abnormal aortic hemodynamics at predilection sites for dissection in patients with Marfan Syndrome: a 4D flow study

2021 ◽  
Vol 22 (Supplement_2) ◽  
Author(s):  
MM Van Andel ◽  
P Van Ooij ◽  
L Gottwald ◽  
V De Waard ◽  
AH Zwinderman ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Private grant(s) and/or Sponsorship. Main funding source(s): AMC Foundation Horstingstuit Foundation Introduction Patients with Marfan syndrome (MFS) may develop aneurysmatic dilatation and dissection of the aorta with a consequence of sudden death at relatively young age. We performed an aortic 4D flow MRI analysis, providing a comprehensive quantification and visualization of abnormal aortic velocity and wall shear stress (WSS) magnitude and direction with recently developed techniques (1,2). We hypothesize that abnormal hemodynamics are found at predilection sites for aortic dissection in MFS patients. Methods This prospective study included 56 MFS patients and 25 healthy subjects as controls. Aortic 4D flow MRI was performed on a 3T Philips Ingenia system (Best, Netherlands). The aorta was manually segmented on time-averaged phase contrast MR angiogram images (phase contrast images multiplied by absolute velocity) by thresholding, watershed, and manual voxel in-/exclusion. The segmentations were used to mask the velocities, calculate WSS, and co-registration for quantification of abnormal hemodynamics (3). Abnormally elevated velocity and WSS were defined as higher than the three-dimensional 95% confidence interval as determined in the control group. Abnormally directed velocity and WSS were defined as vector angle differences higher than 120°. The aorta was subdivided in six regions of interest (ROIs) for total multiple linear regression with age, aortic diameter, and blood pressure characteristics. Independent predictors were defined as characteristics that were significant in the total model. Significance was defined as p < 0.05 with Bonferonni correction. The 3D-maps with abnormal hemodynamics were co-registered and added to create 3D-maps that show the incidence of abnormal hemodynamics. Results Figure 1 shows examples of maps with abnormal velocity and WSS magnitude and direction respectively. Ascending elevated velocity was associated with age, aortic diameter and blood pressure characteristics, whereas elevated WSS was associated with blood pressure characteristics only. No independent predictors were found for abnormally directed hemodynamics. Figure 2 shows the incidence maps for abnormally elevated velocity and abnormally directed WSS in two patients. The maximum incidence for elevated velocity and WSS were 32% and 20%, respectively, and found in the ascending aorta. The maxima for abnormally directed velocity and WSS were 18% and 39%, respectively, and found in the inner proximal descending aorta. Conclusion Altered aortic geometry and wall properties in MFS patients cause detectable hemodynamic effects in 30% of our cohort at known predilection sites for aortic dissection in MFS patients: the ascending aorta and proximal descending aorta. Independent measures of altered hemodynamics could possibly indicate individual patients at risk for aortic dissection.

2015 ◽  
Author(s):  
Michael Delles ◽  
Fabian Rengier ◽  
Yoo-Jin Azad ◽  
Sebastian Bodenstedt ◽  
Hendrik von Tengg-Kobligk ◽  
...  

Author(s):  
Ralf Felix Trauzeddel ◽  
Ulrike Löbe ◽  
Alex Barker ◽  
Carmen Gelsinger ◽  
Christian Butter ◽  
...  

Background Transcatheter aortic valve implantation (TAVI) is a new method for treating patients with severe aortic stenosis with high risk for or rejected from conventional heart surgery. Its impact on blood flow patterns and parameters in the ascending aorta are unknown. Using 4-dimensional phase contrast MRI (4D Flow MRI) we examined the hemodynamics in the ascending aorta after TAVI and compared them to stented bioprostheses and healthy controls. Methods We used 4D Flow MRI (spatial resolution 1.8x1.8x2.5mm3; temporal resolution 13-22 phases/heart cycle) of the ascending aorta in 14 patients with TAVI (mean age 76 years, 8 males, all Edwards Sapien), 12 patients with different stented bioprostheses (mean age 77 years, 8 males) and 9 healthy controls (mean age 55 years, 8 males) controls using a 1.5T MR system. We examined the distribution of the maximum systolic wall shear stresses as well as the maximum blood flow velocities in the mid-ascending aorta. Results Patients with TAVI and stented bioprosthesis revealed an asymetric distribution of the wall shear stresses with significantly elevated values at the anterior and right-anterior curvature and significantly lower values at the posterior curvature compared to the healthy controls. Concerning the maximum velocities both TAVI and stented bioprostheses revealed an asymetric distribution along the right-anterior curvature where TAVI showed a more anterior distribution compared to the healty controls which showed a central distribution. Conclusion The blood flow patterns in patients with TAVI and stented bioprostheses differs significantly from the ones in healthy controls. However, TAVI and stented bioprosthesis showed small but significant regional differences.


PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0248816
Author(s):  
Thomas Puiseux ◽  
Anou Sewonu ◽  
Ramiro Moreno ◽  
Simon Mendez ◽  
Franck Nicoud

A numerical approach is presented to efficiently simulate time-resolved 3D phase-contrast Magnetic resonance Imaging (or 4D Flow MRI) acquisitions under realistic flow conditions. The Navier-Stokes and Bloch equations are simultaneously solved with an Eulerian-Lagrangian formalism. A semi-analytic solution for the Bloch equations as well as a periodic particle seeding strategy are developed to reduce the computational cost. The velocity reconstruction pipeline is first validated by considering a Poiseuille flow configuration. The 4D Flow MRI simulation procedure is then applied to the flow within an in vitro flow phantom typical of the cardiovascular system. The simulated MR velocity images compare favorably to both the flow computed by solving the Navier-Stokes equations and experimental 4D Flow MRI measurements. A practical application is finally presented in which the MRI simulation framework is used to identify the origins of the MRI measurement errors.


2019 ◽  
Vol 1 (1) ◽  
pp. e180009 ◽  
Author(s):  
Bradley D. Allen ◽  
Pascale J. Aouad ◽  
Nicholas S. Burris ◽  
Amir Ali Rahsepar ◽  
Kelly B. Jarvis ◽  
...  

2014 ◽  
Vol 170 (3) ◽  
pp. 426-433 ◽  
Author(s):  
Florian von Knobelsdorff-Brenkenhoff ◽  
Ralf F. Trauzeddel ◽  
Alex J. Barker ◽  
Henriette Gruettner ◽  
Michael Markl ◽  
...  

2020 ◽  
Vol 25 (Supplement 1) ◽  
pp. S98
Author(s):  
Andrea Guala ◽  
Aroa Ruiz-Muñoz ◽  
Lydia Duz-Santoy ◽  
Gisela Teixido-Tura ◽  
Chiara Granato ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document