Long term stability of the subcutaneous cardioverter defibrillator implanted by means of the intermuscular two incision technique

EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
G Bisignani ◽  
A Bisignani ◽  
AL Cavaliere ◽  
M Lovecchio ◽  
S Valsecchi ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background To ensure effective defibrillation with the subcutaneous implantable cardioverter defibrillator (S-ICD), both the lead and the generator must be adequately positioned extrathoracically. We assessed the long-term adequacy of the S-ICD system position and its stability in a group of patients who received the S-ICD by means of the two-incision intermuscular technique. Methods The PRAETORIAN score uses chest radiography to provide feedback on S-ICD positioning, and identifies patients with high defibrillation thresholds. We compared radiographs taken immediately after implantation and on 12-month follow-up examination. Results We analyzed data from 38 patients with the S-ICD generator positioned in an intermuscular pocket. The median PRAETORIAN score was 38 [25th to 75th percentile: 30 to 60]. Two (5%) patients had a score of 90 (intermediate risk of conversion failure). The thickness of the adipose tissue between the coil and the sternum was ≤1 coil width in 72% of patients, the generator was on, or posterior to, the midline in 94% of patients, and the amount of fat tissue between the generator and the thoracic wall was less than the generator width in 78% of patients. No generator or electrode dislodgments were detected on analyzing radiographs collected at the 12-month visit. In all patients, assessment of the PRAETORIAN score confirmed the values calculated on post-implantation analysis. During follow-up, no ineffective therapies, sudden cardiac or device-related deaths occurred. Conclusions The position of the S-ICD system implanted using the two-incision intermuscular technique was adequate at the time of implantation and remained stable after 12 months.

EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
D Musat ◽  
NS Milstein ◽  
M Saberito ◽  
A Bhatt ◽  
M Habibi ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background Cryoballoon pulmonary vein isolation (CB) is an accepted method for ablation in patients with atrial fibrillation (AF). A three-month blanking period (BP) is commonly used in clinical trials and practice. However, when the optimal BP duration differs in patients (pts) on or off an antiarrhythmic drug (AAD) at time of ablation remains undefined. Objective To compare the BP duration in pts undergoing CB while either taking or not taking an AAD. Methods We enrolled consecutive pts with AF who had CB PVI while on an AAD. All pts had an implantable loop recorder (ILR). We prospectively followed all pts and determined the time to last AF episode during the 90-day post-PVI BP. This was then correlated with likelihood of having an AF recurrence between 3-12 months post-PVI. Results The cohort included 164 pts (66 ± 9 years; 97 [60%] male; 90 [55%] PAF; CHA2DS2-VASc 2.7 ± 1.7). Ablation was performed with 92 (56%) pts taking an AAD, which was stopped at a median of 80 [36, 105] days post-PVI. We defined 4 distinct groups: (1) no AF in 90-day BP (n = 75 [46%]); (2) last AF within 30 days of PVI (n = 32 [20%]); (3) last AF within 60 days of PVI (n = 17 [10%]); and (4) last AF within 90 days of PVI (n = 40 [24%]). Following the 90-day BP, 81 (49%) pts had a recurrence of AF. Long-term freedom from recurrent AF was similar in pts who did and did not use an AAD, irrespective of BP duration (Figure). Conclusion Our data suggest that the optimal BP duration in AF patients undergoing CB PVI while taking an AAD is 30 days. An AF recurrence after 30 days is associated with a very high likelihood of recurrent AF during longer-term follow-up, irrespective of whether an AAD is being used or not. Abstract Figure.


2018 ◽  
Vol 41 (6) ◽  
pp. 583-588 ◽  
Author(s):  
Maria Licia Ribeiro Cury Pavão ◽  
Elerson Arfelli ◽  
Adilson Scorzoni-Filho ◽  
Anis Rassi ◽  
Antônio Pazin-Filho ◽  
...  

2021 ◽  
pp. 247412642097887
Author(s):  
Gregg T. Kokame ◽  
Tarin T. Tanji ◽  
Jase N. Omizo

Purpose: We report the longest follow-up to our knowledge of stable scleral fixation of a posterior chamber intraocular lens (PC IOL) with 10-0 polypropylene sutures. Methods: A retrospective review is presented of a case with more than 30 years’ follow-up after performing sutured scleral fixation with 10-0 polypropylene suture using 2 sutures tied together under a scleral flap. One suture was a cow-hitch looped around the haptic, and the other suture was passed through the sclera to create the scleral fixation. Results: The scleral fixation with 10-0 polypropylene suture knots for both haptics of the PC IOL allowed central optic positioning with excellent vision for more than 30 years without suture breakage. Conclusions: Polypropylene sutures for scleral fixation of PC IOLs remained stable for more than 30 years with central positioning of the PC IOL, without exposure of the fixation suture knots through the conjunctiva, and without suture breakage.


2021 ◽  
Vol 12 ◽  
Author(s):  
Ruben M. Strijbos ◽  
Louise V. Straatman ◽  
Tim G. A. Calon ◽  
Martin L. Johansson ◽  
Arthur J. G. de Bruijn ◽  
...  

Objective: Comparing the surgical outcomes of the Minimally Invasive Ponto Surgery (MIPS) technique with the linear incision technique with soft tissue preservation (LITT-P) for bone conduction devices after a follow-up of 22 months.Methods: In this multicenter randomized controlled trial, there was the inclusion of 64 adult patients eligible for unilateral surgery. There was 1:1 randomization to the MIPS (test) or the LITT-P (control) group. The primary outcome was an (adverse) soft tissue reaction. Secondary outcomes were pain, loss of sensibility, soft tissue height/overgrowth, skin sagging, implant loss, Implant Stability Quotient measurements, cosmetic scores, and quality of life questionnaires.Results: Sixty-three subjects were analyzed in the intention-to-treat population. No differences were found in the presence of (adverse) soft tissue reactions during complete follow-up. Also, there were no differences in pain, wound dehiscence, skin level, soft tissue overgrowth, and overall quality of life. Loss of sensibility (until 3-month post-surgery), cosmetic scores, and skin sagging outcomes were better in the MIPS group. The Implant Stability Quotient was higher after the LITT-P for different abutment lengths at various points of follow-up. Implant extrusion was nonsignificantly higher after the MIPS (15.2%) compared with LITT-P (3.3%).Conclusion: The long-term results show favorable outcomes for both techniques. The MIPS is a promising technique with some benefits over the LITT-P. Concerns regarding nonsignificantly higher implant loss may be overcome with future developments and research.Clinical Trial Registration:www.ClinicalTrials.gov, identifier: NCT02438618.


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
U Nguyen ◽  
M Strik ◽  
S Abu-Arib ◽  
A Bruekers ◽  
T Nguyen ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Purpose To evaluate electrocardiographic (ECG) characteristics at first presentation in patients with possible coronavirus disease (COVID-19) pneumonia. Methods and results 356 patients presenting at the emergency room with possible COVID-19 pneumonia based on clinical presentation and computed tomography findings were included and subdivided into a COVID-19 positive group ([COVID-19-positive], n = 231, 65%) and a COVID-19 negative group ([COVID-19-negative], n = 125, 35%) based on polymerase chain reaction tests. The study population was predominantly middle aged-elderly (67 ± 14 year; n = 235, 66% male). Mortality rate was 24% after 1-month follow-up. There were no significant (NS) differences in sex, age, and mortality between the COVID-19-positive and COVID-19-negative group.  Atrial fibrillation (AF) was common (9%), though its prevalence was NS (regression analyses adjusted for age and sex) different in the COVID-19-positive vs. the COVID-19-negative group. ECG characteristics reflecting atrial enlargement and repolarization abnormalities were frequently present (<38% and 14% respectively). No significant differences were found between the COVID-19-positive vs. the COVID-19-negative group for the majority of morphological ECG characteristics (Figure 1 for more detailed data).  Conclusion AF and ECG characteristics reflecting atrial enlargement and repolarization abnormalities are commonly present in COVID-19 patients. The prevalence of these ECG characteristics however do NS differ from their COVID-19-negative counterparts. Abstract Figure.


2021 ◽  
Vol 28 (Supplement_1) ◽  
Author(s):  
L Kuzma ◽  
EJ Dabrowski ◽  
A Kurasz ◽  
M Swieczkowski ◽  
H Bachorzewska-Gajewska ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background The short-term effect of air pollution on cardiovascular mortality is well-documented but a scarce number of studies focus on cause-specific mortality in low-polluted areas. Purpose We decided to distinguish deaths due to cerebrovascular disease (CbVD) from a region widely known as the Green Lungs of Poland to assess the short-term effect of air pollution on CbVD mortality. Methods The analysis with almost 4,500,000 person-years of follow-up with a time-stratified case-crossover design was performed. Results are reported as odds ratio (OR) associated with an increase in interquartile range (IQR) of air pollution. Results In the overall analysis of the studied region PM2.5 had an impact on increased CbVD mortality at LAG 0 (OR 1.046, 95% CI 1.013 – 1.080, P = 0.006), LAG 0-1 (1.048, 1.002-1.082, P = 0.040), and LAG 0-3 (1.052, 1.015-1.090, P = 0.006). The influence of PM10 was noted at LAG 0 (1.041, 1.002-1.082, P = 0.040). CbVD mortality in Bialystok was increased by exposure to PM10 at LAG 0 (1.05, 1.00-1.09, P = 0.048) and CO at LAG 1 (1.07, 1.00-1.14, P = 0.04). Additionally, an effect of CO was observed in cold season at LAG 1 (1.09, 1.02-1.17, P = 0.02), LAG 0-1 (1.08, 1.00-1.016, P = 0.04), and LAG 0-3 (1.09, 1.01-1.18, P = 0.04). In Suwalki, an impact of PM2.5 was also observed. Conclusions A short-term increase in air pollutants concentrations, especially in PM2.5 and CO, had an influence on CbVD mortality. Mortality rates were significantly increased in cold season. We also found heterogeneity in the influence of major contributors on mortality between analyzed cities.


2019 ◽  
Vol 2019 ◽  
pp. 1-6 ◽  
Author(s):  
Nils Kristian Prenzler ◽  
Eugen Kludt ◽  
Thomas Giere ◽  
Rolf Salcher ◽  
Thomas Lenarz ◽  
...  

Objectives/Hypothesis. Comparing long term stability of the Middle Ear Transducers (MET) of the 1st generation T1 (Otologics LLC) with the current generation T2 (Cochlear Ltd.) in all our clinical cases with standard incus coupling. Study Design. Retrospective chart review. Methods. 52 ears implanted with a MET device between 2008 and 2016 were analyzed retrospectively. All patients suffered from sensorineural hearing loss and the actuator was coupled to the body of the incus (standard coupling). 23 ears were implanted with the transducer T1 (Otologics LLC) between 2008 and 2011 and 29 ears were implanted with the current transducer T2 since 2011 (Otologics LLC/Cochlear Ltd.). Latest available in situ and bone conduction (BC) thresholds were exploited for a follow-up period of up to 7 years after first fitting. Long term stability of coupling and actuator performance was evaluated by tracking differences between in situ and BC thresholds. Results. In the T1 group, 9 out of 23 implants were still used by the patients at their last follow-up visit (average observation time 3.7 yrs.; min 1.0 yrs., max 7.4 yrs.). In 9 patients a technical failure identified by a decrease of in situ threshold of more than 15 dB compared to BC thresholds [Δ (in situ – BC)] lead to non-usage of the implant and 7 explantations. Five other explantations occurred due to medical reasons such as BC threshold decrease, infection, or insufficient speech intelligibility with the device. In the T2 group, 23 out of 29 implants were still used at the most current follow-up visit (average observation time 3.3 yrs.; min 1.0 yrs., max 4.8 yrs.). No technical failures were observed up to more than 4 years after implantation. Five T2 patients discontinued using the device due to insufficient benefit; two of these patients were explanted. One patient had to be explanted before the activation of the device due to disorders of wound healing. Nevertheless, a small but significant decrease of hearing loss corrected coupling efficiency [Δ (in situ – BC)] was seen in the T2 group. Conclusions. In contrast to the T1 transducers of the earlier generation of MET systems where technical failures occurred frequently, no technical failures were detected after 29 implantations with the current T2 transducers. However, a small but significant decline of transmission efficiency was observable even in the T2 implanted group.