Determination of Cinnamyl Anthranilate in Perfume, Cologne, and Toilet Water by Liquid Chromatography with Fluorescence Detection

1987 ◽  
Vol 70 (6) ◽  
pp. 958-960
Author(s):  
Francois X Demers ◽  
Ronald L Yates ◽  
Henry M Davis

Abstract A liquid chromatographic method with fluorescence detection was developed for the determination of cinnamyl anthranilate in perfumes and other fragrance compositions. The method was evaluated by conducting recovery studies of 10 different commercial fragrance compositions to which cinnamyl anthranilate had been added at levels of 0.1, 0.5, and 1.0 mg/mL. Recoveries ranged from 91 to 103% with a mean of 97% and a standard deviation of ±3.3%.

1986 ◽  
Vol 69 (6) ◽  
pp. 1026-1030
Author(s):  
Bruce C Flann ◽  
Bruce A Lodge

Abstract The validation of a liquid chromatographic procedure suitable for the determination of calcitriol and alfacalcidol in their respective formulations labeled to contain at least 0.25 μ.g drug per unit is described. The capsule content is diluted and chromatographed in 15-20 min on silica columns (5 μm) with a mobile phase of hexane-tetrahydrofuranmethylene dichloride-isopropanol (72 + 12 + 12 + 4, v/v) with detection at 254 nm. The calibration curve is linear. Recoveries of “spikes” averaged 101% with a standard deviation of 2%. Precision was better than 1.5%.


1993 ◽  
Vol 76 (1) ◽  
pp. 92-94 ◽  
Author(s):  
Paolo Cabras ◽  
Marinella Melis ◽  
Lorenzo Spanedda

Abstract A liquid chromatographic method is described for the determination of cymiazole residues in honey. This acaricide is determined on a reversed-phase (C18) column, with a CH3CN-O.OOIN HCI-NaCI mixture (950 mL + 50 mL + 0.3 g/L) as the mobile phase, and UV detection at 265 nm. Cymiazole is extracted with n-hexane from aqueous alkalinized (pH 9) honey solutions. No further cleanup of the honey extract was required before chromatographic analysis. Recoveries on control samples fortified with 0.01,0.10, and 1.00 ppm cymiazole ranged from 92 to 102%. The limit of determination was 0.01 ppm.


1975 ◽  
Vol 58 (4) ◽  
pp. 754-756 ◽  
Author(s):  
George M Ware

Abstract Patulin is extracted from apple butter samples with ethyl acetate and the extract is cleaned up on a silica gel column, using benzene-ethyl acetate (75+25) as the eluant. High-pressure liquid chromatography, using a 25 cm Zorbax-Sil column, isooctane-ethyl ether-acetic acid (750+250+0.5) as the mobile solvent, and a 254 nm ultraviolet detector, is used for the determinative step. Under these conditions, patulin is eluted before 5-hydroxymethylfurfural, a component of apple butter which interferes with other liquid chromatographic and thin layer chromatographic methods. Recoveries of patulin added at levels of 34.6, 138.4, and 276.8 μg/kg ranged from 89.0 to 112.1%.


1990 ◽  
Vol 73 (4) ◽  
pp. 595-598
Author(s):  
Stephen C Slahck

Abstract A liquid chromatographic method for determination of cyfluthrin (Baythrold®, Tempo®) diastereomers In technical and formulated products has been developed. Samples are dissolved in dloxane-hexane and analyzed by normal-phase liquid chromatography using acetophenone as an internal standard. The method Is applicable to technical Baythrold, Baythrold 2 EC, Tempo 20 WP, and granular formulations. The method separates all 4 diastereomers of cyfluthrin and all impurities in less than 19 mln.


1978 ◽  
Vol 39 (02) ◽  
pp. 466-473 ◽  
Author(s):  
Thorir D Bjornsson ◽  
Sarah E Swezey ◽  
Peter J Meffin ◽  
Terrence F Blaschke

SummaryA convenient, accurate and reproducible high pressure liquid chromatographic method for the quantitation of radio-labelled vitamin K1 and vitamin K1 epoxide in plasma is described. The method involves the determination of total ether extractable radioactivity, and a chromatographic separation to determine the relative quantities of radio-labelled vitamin K1 and vitamin K1 epoxide. The method is useful over a wide range of ratios of the two compounds, and has a coefficient of variation of approximately 5%.


1977 ◽  
Vol 23 (6) ◽  
pp. 957-959 ◽  
Author(s):  
G R Gotelli ◽  
P M Kabra ◽  
L J Marton

Abstract We describe a sensitive and precise high-pressure liquid chromatographic method in which acetoacetanilide is used as the internal standard to simultaneously determine acetaminophen and phenacetin in plasma. Therapeutic as well as toxic concentrations can be determined on as little as 0.1 ml of plasma. Sample preparation is rapid and chromatography is complete in 5 min. Quantitation is accurate at 0.5 mg/liter concentration for both drugs. Day-to-day precision within 5% is attainable. Of 36 other drugs tested, only theophylline interfered, with the determination of acetaminophen.


1988 ◽  
Vol 71 (1) ◽  
pp. 36-37
Author(s):  
Ramesh J Trivedi

Abstract A simple, sensitive, and rapid liquid chromatographic method for quantitating α-ionone in toothpaste at levels of 20 ppm in the presence of large amounts of flavor has been developed. The method is accurate, precise, cost-effective, and specific for α-ionone. Average recovery of a laboratory-prepared sample was 99.0% with the relative standard deviation was 1.29% (n = 6).


Sign in / Sign up

Export Citation Format

Share Document