scholarly journals Determination of the Cross-Reactivities for -Zearalenol, -Zearalenol, Zearalanone, -Zearalanol, and -Zearalanol on Three Commercial Immunoaffinity Columns Targeting Zearalenone

2007 ◽  
Vol 90 (4) ◽  
pp. 1197-1202 ◽  
Author(s):  
Marianne Erbs ◽  
Nccolo Hartmann ◽  
Thomas D Bucheli

Abstract Immunoaffinity extraction has become increasingly important as a sample preparation and cleanup method in mycotoxin analysis. In this study, the antibody specificities of 3 commercial immunoaffinity columns (IACs) targeting zearalenone (ZON) were compared for -zearalenol, -zearalenol, zearalanone, -zearalanol, and -zearalanol. The recoveries of ZON and its 5 analogs were determined in triplicate when extracted from 10 mL circumneutral river water samples spiked with 20 ng analyte individually or in a mixture. The analytes were analyzed by means of electrospray ionization liquid chromatography/tandem mass spectrometry using deuterated internal standards for quantitation. Recoveries ranged from 69 to 115% for all analytes with relative standard deviations of 139%. Cross-reactivities for the analogs were >80% when applied both individually and in a mixture. No significant competition effects were observed when the compounds were applied as a multianalyte mixture well below the stated IAC capacities. The results obtained here demonstrate that all IACs tested are highly cross-reactive towards the 5 ZON derivatives and may be applied for their simultaneous extraction or cleanup.

2004 ◽  
Vol 50 (8) ◽  
pp. 1391-1395 ◽  
Author(s):  
Eduard A Struys ◽  
Erwin E W Jansen ◽  
Nanda M Verhoeven ◽  
Cornelis Jakobs

Abstract Background: The differential diagnosis of d-2-hydroxyglutaric aciduria (d-2-HGA), l-2-hydroxyglutaric aciduria (l-2-HGA), and the combined d/l-2-hydroxyglutaric aciduria (d/l-2-HGA) can be accomplished only by the measurement of the corresponding 2-hydroxyglutarate (2-HG). Available methods for the determination of d- and l-2-HG in urine are either time-consuming and expensive or have not been extensively validated. We aimed to develop a method for their rapid and sensitive measurement. Methods: We used liquid chromatography–tandem mass spectrometry (LC-MS/MS) for the determination of d- and l-2-HG with stable-isotope-labeled internal standards. Urine samples of 20 μL were mixed with 250 μL of methanol containing the internal standards and subsequently dried under nitrogen. The analytes were derivatized by use of diacetyl-l-tartaric anhydride (DATAN) to obtain diastereomers, which were separated on an achiral C18 HPLC column and detected by MS/MS in multiple-reaction-monitoring mode. Results: The use of DATAN as chiral derivatization reagent provided very well separated peaks of the formed diastereomers of d- and l-2-HG, with a total runtime of 5 min. The inter- and intraassay CVs for d- and l-2-HG ranged from 3.4% to 6.2%. Mean recoveries of d- and l-2-HG, evaluated on two concentrations, were 94%. Detection limit of the presented method was 20 pmol for a sample volume of 20 μL. Method comparison of the LC-MS/MS method with a gas chromatography–mass spectrometry method, in which d- and l-2-HG were derivatized with R-(−)-butanol, showed good agreement between the two methods. Conclusions: Urinary d- and l-2-HG can be analyzed by MS/MS after derivatization with DATAN. The presented method may be suitable for the differential diagnosis of 2-HGA.


Molecules ◽  
2020 ◽  
Vol 25 (5) ◽  
pp. 1254 ◽  
Author(s):  
Won-Gu Choi ◽  
Dong Kyun Kim ◽  
Yongho Shin ◽  
Ria Park ◽  
Yong-Yeon Cho ◽  
...  

Doxorubicin, an anthracycline antitumor antibiotic, acts as a cancer treatment by interfering with the function of DNA. Herein, liquid chromatography-tandem mass spectrometry was for the first time developed and validated for the simultaneous determination of doxorubicin and its major metabolites doxorubicinol, doxorubicinone, doxorubicinolone, and 7-deoxydoxorubicinone in mouse plasma. The liquid–liquid extraction of a 10 μL mouse plasma sample with chloroform:methanol (4:1, v/v) and use of the selected reaction monitoring mode led to less matrix effect and better sensitivity. The lower limits of quantification levels were 0.5 ng/mL for doxorubicin, 0.1 ng/mL for doxorubicinol, and 0.01 ng/mL for doxorubicinone, doxorubicinolone, and 7-deoxydoxorubicinone. The standard curves were linear over the range of 0.5–200 ng/mL for doxorubicin; 0.1–200 ng/mL for doxorubicinol; and 0.01–50 ng/mL for doxorubicinone, doxorubicinolone, and 7-deoxydoxorubicinone in mouse plasma. The intra and inter-day relative standard deviation and relative errors for doxorubicin and its four metabolites at four quality control concentrations were 0.9–13.6% and –13.0% to 14.9%, respectively. This method was successfully applied to the pharmacokinetic study of doxorubicin and its metabolites after intravenous administration of doxorubicin at a dose of 1.3 mg/kg to female BALB/c nude mice.


2017 ◽  
Vol 80 (12) ◽  
pp. 2112-2118 ◽  
Author(s):  
Dan Hu ◽  
Xu Xu ◽  
Tian Cai ◽  
Wei-Ying Wang ◽  
Chun-Jie Wu ◽  
...  

ABSTRACTA rapid and sensitive analytical method based on high-performance liquid chromatography–tandem mass spectrometry was developed and validated for the determination of isopyrazam (IZM) and azoxystrobin (AZT) in cucumbers. A modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method was used as the pretreatment procedure. The samples were extracted with acetonitrile and cleaned up with octadecylsilyl silica (C18) and graphite carbon black. The proposed method resulted in satisfactory recovery of IZM and AZT (91.48 to 114.62%), and relative standard deviations were less than 13.1% at fortification concentrations of 1, 20, and 500 μg kg−1 (n = 3). The limits of quantification for IZM and AZT were 0.498 and 0.499 μg kg−1, respectively, which are far below the maximum residue level (0.5 mg kg−1) established for this type of sample. Matrix effects were also evaluated. This study established a sensitive and fast method for the detection of IZM and AZT in cucumber samples.


Molecules ◽  
2020 ◽  
Vol 25 (19) ◽  
pp. 4399
Author(s):  
Dasom Shin ◽  
Hui-Seung Kang ◽  
Hyungsoo Kim ◽  
Guiim Moon

In this work, liquid chromatography–tandem mass spectrometry (LC-MS/MS) method was developed and validated for screening and confirmation of 64 illicit compounds in dietary supplements. The target compounds were illegally used pharmaceutical drugs, prohibited compounds, and not authorized ingredients for different therapeutics (sexual enhancement, weight loss, muscular strengthening, and relaxing products). The validation procedure was performed to evaluate selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, and precision according to the Association of Official Analytical Chemists guidelines. The linearity was >0.98 in the range of 0.5–200 µg L−1. The LOQs were in the range 1–10 µg kg−1 for all target compounds. The accuracy (expressed as recovery) was 78.5–114%. The precision (expressed as the relative standard deviation) was below 9.15%. The developed method was applied for the determination of illicit compounds in dietary supplements collected from websites. As a result, the total detection rate was 13.5% (27 samples detected in 200 samples). The concentrations of detected samples ranged from 0.51 to 226 mg g−1. The proposed methodology is suitable for monitoring the adulteration of illicit compounds in dietary supplements.


2014 ◽  
Vol 852 ◽  
pp. 266-269
Author(s):  
Xiao Fang Wang ◽  
Chun Liang Yang ◽  
Mao Fang Huang ◽  
Ming Yue Wang ◽  
Yu Bing Zha ◽  
...  

The conditions for detecting residues of diflubenzuron in vegetables by ultra high performance liquid chromatography tandem mass spectrometry were studied. The target was extracted with acetonitrile for 2 min with a homogenizer. The extaction was purifide by a conditioned Florisil SPE cartridge, and then was detected by ultra high-performance liquid chromatography with tandem mass spectrometry. The average recovery was in the range from 87.8 %- 99.2 % at spike levels of 0.1, 1.0 and 10 mg/kg in vegetables, and relative standard deviations was in the range of 4.2 %-8.9 %. The proposed method is fast, simple, sensitive and accurate.


Author(s):  
Misuk Ji ◽  
Sollip Kim ◽  
Hee-Jung Chung ◽  
Woochang Lee ◽  
Sail Chun ◽  
...  

AbstractLiquid chromatography-tandem mass spectrometry (LC-MS/MS) is widely used for therapeutic drug monitoring of immunosuppressants given to transplant recipients. This study evaluated the performance of the newly introduced MassTrak Immunosuppressant XE Kit (Waters Corporation; “the Kit”) in the determination of everolimus and cyclosporin A (CsA) using LC-MS/MS.The linearity, precision, detection limit, carryover and matrix effect of the Kit and comparison of the in-house method and Kit procedure were evaluated according to Clinical and Laboratory Standards Institute guidelines.The Kit afforded good linearity in the measurement of everolimus from 2 to 26 ng/mL (RThe Kit employing isotopically labeled internal standards provides reliable measurements of immunosuppressant levels over a broad range of concentrations.


Sign in / Sign up

Export Citation Format

Share Document