A Novel Liquid Chromatography Tandem Mass Spectrometry Technique using Multi-Period-Multi-Experiment of MRM-EPI-MRM3 with Library Matching for Simultaneous Determination of Amphetamine Type Stimulants Related Drugs in Whole Blood, Urine and Dried Blood Stain (DBS)—Application to Forensic Toxicology Cases in Malaysia

2019 ◽  
Vol 43 (7) ◽  
pp. 528-535 ◽  
Author(s):  
Fathiah A Zubaidi ◽  
Yeun-Mun Choo ◽  
Guan-Huat Tan ◽  
Hamimah Abd Hamid ◽  
Yap Ken Choy

Abstract A novel mass spectrometry detection technique based on a multi-period and multi- experiment (MRM-EPI-MRM3) with library matching in a single run for fast and rapid screening and identification of amphetamine type stimulants (ATS) related drugs in whole blood, urine and dried blood stain was developed and validated. The ATS-related drugs analyzed in this study include ephedrine, pseudoephedrine, amphetamine, methamphetamine, MDMA (3,4-Methylenedioxymethamphetamine), MDA (3,4-Methylenedioxyamphetamine), MDEA (3,4-Methylenedioxy-N-ethylamphetamine) and phentermine. The relative standard deviation for inter and intraday was less than 15% while recoveries ranged from 80% to 120% for all three matrices, i.e., whole blood, urine and dried blood stain. All compounds gave library matching percentage of more than 85% based on the purity. This method was proven to be simple and robust, and provide high confident results complemented with library matching confirmation.

Molecules ◽  
2020 ◽  
Vol 25 (5) ◽  
pp. 1254 ◽  
Author(s):  
Won-Gu Choi ◽  
Dong Kyun Kim ◽  
Yongho Shin ◽  
Ria Park ◽  
Yong-Yeon Cho ◽  
...  

Doxorubicin, an anthracycline antitumor antibiotic, acts as a cancer treatment by interfering with the function of DNA. Herein, liquid chromatography-tandem mass spectrometry was for the first time developed and validated for the simultaneous determination of doxorubicin and its major metabolites doxorubicinol, doxorubicinone, doxorubicinolone, and 7-deoxydoxorubicinone in mouse plasma. The liquid–liquid extraction of a 10 μL mouse plasma sample with chloroform:methanol (4:1, v/v) and use of the selected reaction monitoring mode led to less matrix effect and better sensitivity. The lower limits of quantification levels were 0.5 ng/mL for doxorubicin, 0.1 ng/mL for doxorubicinol, and 0.01 ng/mL for doxorubicinone, doxorubicinolone, and 7-deoxydoxorubicinone. The standard curves were linear over the range of 0.5–200 ng/mL for doxorubicin; 0.1–200 ng/mL for doxorubicinol; and 0.01–50 ng/mL for doxorubicinone, doxorubicinolone, and 7-deoxydoxorubicinone in mouse plasma. The intra and inter-day relative standard deviation and relative errors for doxorubicin and its four metabolites at four quality control concentrations were 0.9–13.6% and –13.0% to 14.9%, respectively. This method was successfully applied to the pharmacokinetic study of doxorubicin and its metabolites after intravenous administration of doxorubicin at a dose of 1.3 mg/kg to female BALB/c nude mice.


2017 ◽  
Vol 80 (12) ◽  
pp. 2112-2118 ◽  
Author(s):  
Dan Hu ◽  
Xu Xu ◽  
Tian Cai ◽  
Wei-Ying Wang ◽  
Chun-Jie Wu ◽  
...  

ABSTRACTA rapid and sensitive analytical method based on high-performance liquid chromatography–tandem mass spectrometry was developed and validated for the determination of isopyrazam (IZM) and azoxystrobin (AZT) in cucumbers. A modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method was used as the pretreatment procedure. The samples were extracted with acetonitrile and cleaned up with octadecylsilyl silica (C18) and graphite carbon black. The proposed method resulted in satisfactory recovery of IZM and AZT (91.48 to 114.62%), and relative standard deviations were less than 13.1% at fortification concentrations of 1, 20, and 500 μg kg−1 (n = 3). The limits of quantification for IZM and AZT were 0.498 and 0.499 μg kg−1, respectively, which are far below the maximum residue level (0.5 mg kg−1) established for this type of sample. Matrix effects were also evaluated. This study established a sensitive and fast method for the detection of IZM and AZT in cucumber samples.


Toxins ◽  
2019 ◽  
Vol 11 (4) ◽  
pp. 196 ◽  
Author(s):  
Ali Alsharif ◽  
Yeun-Mun Choo ◽  
Guan-Huat Tan

Mycotoxins are common food contaminants which cause poisoning and severe health risks to humans and animals. The present study applied chemometric approach in liquid chromatography-tandem mass spectrometry (LC-MS/MS) optimization for simultaneous determination of mycotoxins, i.e., aflatoxins B1, B2, G1, and G2, and ochratoxin A. The validated quick, easy, cheap, effective, rugged, and safe (QuEChERS)-LC-MS/MS method was used to study the occurrence of mycotoxins in 120 food matrices. The recovery ranges from 81.94% to 101.67% with relative standard deviation (RSD) lesser than 11%. Through the developed method, aflatoxins were detected in raisin, pistachio, peanut, wheat flour, spice, and chili samples with concentration ranges from 0.45 to 16.93 µg/kg. Trace concentration of ochratoxin A was found in wheat flour and peanut samples which ranged from 1.2 to 3.53 µg/kg. Some of the tested food samples contained mycotoxins of above the European legal maximum limit.


Molecules ◽  
2020 ◽  
Vol 25 (19) ◽  
pp. 4399
Author(s):  
Dasom Shin ◽  
Hui-Seung Kang ◽  
Hyungsoo Kim ◽  
Guiim Moon

In this work, liquid chromatography–tandem mass spectrometry (LC-MS/MS) method was developed and validated for screening and confirmation of 64 illicit compounds in dietary supplements. The target compounds were illegally used pharmaceutical drugs, prohibited compounds, and not authorized ingredients for different therapeutics (sexual enhancement, weight loss, muscular strengthening, and relaxing products). The validation procedure was performed to evaluate selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, and precision according to the Association of Official Analytical Chemists guidelines. The linearity was >0.98 in the range of 0.5–200 µg L−1. The LOQs were in the range 1–10 µg kg−1 for all target compounds. The accuracy (expressed as recovery) was 78.5–114%. The precision (expressed as the relative standard deviation) was below 9.15%. The developed method was applied for the determination of illicit compounds in dietary supplements collected from websites. As a result, the total detection rate was 13.5% (27 samples detected in 200 samples). The concentrations of detected samples ranged from 0.51 to 226 mg g−1. The proposed methodology is suitable for monitoring the adulteration of illicit compounds in dietary supplements.


Sign in / Sign up

Export Citation Format

Share Document