Diagnostic Performance of Contrast-enhanced Mammography: Comparison With MRI and Mammography

Author(s):  
Sabahattin Yüzkan ◽  
Duygu Cengiz ◽  
İlhan Hekimsoy ◽  
Özlem Sezgin Okçu ◽  
Ayşenur Oktay

Abstract Objective To compare the diagnostic performance of contrast-enhanced mammography (CEM) with MRI and mammography (MG) based on histopathological results. Methods In this IRB-approved study, written informed consent was obtained from all patients. Images from 40 patients (62 lesions) with suspicious findings on US between March 2018 and August 2018 were evaluated. Sensitivity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of CEM, MRI, and MG were evaluated and compared within a 95% confidence interval. Maximum dimensions of lesions were measured and correlations of results were evaluated with Spearman’s Rho test. Results In the histopathological analysis, 66% (41/62) of lesions were malignant and 34% (21/62) lesions were benign. Contrast-enhanced mammography, MRI, and MG had sensitivities of 100% (41/41), 100% (41/41), and 80% (33/41), respectively. The sensitivity of CEM and MRI was significantly better than that of MG (P = 0.03). The NPVs of CEM (100%, 7/7) and MRI (100%, 14/14) were statistically higher than the NPV of MG (60%, 12/20) (P = 0.03). The false-positive rates for CEM, MRI, and MG were 33% (7/21), 66% (14/21), and 42% (9/21), respectively. Contrast-enhanced mammography had a significantly lower false-positive rate than MRI (P < 0.001). Mammography had the highest false-negative rate, missing 19% (8/41) of malignant lesions. Conclusion Contrast-enhanced mammography has similar performance characteristics to MRI and improved performance characteristics relative to MG. In particular, CEM and MRI have similar sensitivity and NPVs and both are superior in each of these metrics to MG.

2018 ◽  
Vol 29 (4) ◽  
pp. 435-441 ◽  
Author(s):  
Kazuyoshi Kobayashi ◽  
Kei Ando ◽  
Ryuichi Shinjo ◽  
Kenyu Ito ◽  
Mikito Tsushima ◽  
...  

OBJECTIVEMonitoring of brain evoked muscle-action potentials (Br[E]-MsEPs) is a sensitive method that provides accurate periodic assessment of neurological status. However, occasionally this method gives a relatively high rate of false-positives, and thus hinders surgery. The alarm point is often defined based on a particular decrease in amplitude of a Br(E)-MsEP waveform, but waveform latency has not been widely examined. The purpose of this study was to evaluate onset latency in Br(E)-MsEP monitoring in spinal surgery and to examine the efficacy of an alarm point using a combination of amplitude and latency.METHODSA single-center, retrospective study was performed in 83 patients who underwent spine surgery using intraoperative Br(E)-MsEP monitoring. A total of 1726 muscles in extremities were chosen for monitoring, and acceptable baseline Br(E)-MsEP responses were obtained from 1640 (95%). Onset latency was defined as the period from stimulation until the waveform was detected. Relationships of postoperative motor deficit with onset latency alone and in combination with a decrease in amplitude of ≥ 70% from baseline were examined.RESULTSNine of the 83 patients had postoperative motor deficits. The delay of onset latency compared to the control waveform differed significantly between patients with and without these deficits (1.09% ± 0.06% vs 1.31% ± 0.14%, p < 0.01). In ROC analysis, an intraoperative 15% delay in latency from baseline had a sensitivity of 78% and a specificity of 96% for prediction of postoperative motor deficit. In further ROC analysis, a combination of a decrease in amplitude of ≥ 70% and delay of onset latency of ≥ 10% from baseline had sensitivity of 100%, specificity of 93%, a false positive rate of 7%, a false negative rate of 0%, a positive predictive value of 64%, and a negative predictive value of 100% for this prediction.CONCLUSIONSIn spinal cord monitoring with intraoperative Br(E)-MsEP, an alarm point using a decrease in amplitude of ≥ 70% and delay in onset latency of ≥ 10% from baseline has high specificity that reduces false positive results.


Author(s):  
Josiane Steinmetz ◽  
Joseph Henny ◽  
René Gueguen

AbstractThe aim of the present work was to compare in a supposed healthy population of 680 subjects several algorithms for positive selection of urine samples requiring microscopic examination for erythrocytes and leukocytes after screening by automated test-strip measurement and particle counting on a Sysmex UF-50™ flow cytometer. Four strategies have been formulated and the sensitivity, specificity, positive predictive value, negative predictive value, false positive rate, false negative rate, and microscopic review rate were measured. The strategy combining test strip analysis and automated counting on all samples, followed by microscopic examination of only discordant samples gave the best results. When the two methods of haematuria screening were in agreement (91% of samples), the false negative rate for microscopy was 1.1%, with a false positive rate of 0.8%, sensitivity of 66% and specificity of 99%, and the results are acceptable without any other examination. When the two methods of haematuria screening were discrepant, visual microscopic analysis was necessary to obtain definitive results. For leukocyturia screening, 80% of results were in agreement by test strip and automatic sediment urinalysis, with only ten results considered as false negatives (1.8%) and four as false positives (0.7%). Agreement was good and the other criteria were good (sensitivity 79%, specificity 99%). On conflicting samples, there was no agreement between methods and microscopic analysis was essential. The benefit of such an algorithm would be optimisation of the workflow without any loss of sensitivity and specificity at the expense of a two-fold increase in cost.


2021 ◽  
Vol 162 (20) ◽  
pp. 790-799
Author(s):  
Zoárd Tibor Krasznai ◽  
Zsuzsa Bagoly ◽  
Eszter Nagy ◽  
Zsolt Farkas ◽  
Róbert Póka ◽  
...  

Összefoglaló. Bevezetés: Bevezetés: A citológiai alapú méhnyakrákszűrés átmeneti kategóriáinak optimális menedzselése a humán papillomavírus (HPV) szűrése és tipizálása ellenére jelenleg is kihívás. Vizsgálatunk célja a modern cervixspektroszkópiának (multimodális hiperspektroszkópia – MHS), egy azonnali eredményt nyújtó, digitális technológiára épülő módszernek a vizsgálata volt a citológiai alapú méhnyakszűrés találati biztonságának javítására. Betegek és módszer: Vizsgálatainkat 208, 18 és 75 év közötti nőbeteg bevonásával végeztük, akiknél már indikálásra került valamely, a méhnyakon végzendő műtét, citológiai eredményük rendelkezésre állt (a HPV-tesztet, amennyiben nem történt meg, elvégeztük), valamint valamennyi betegnél elvégeztük a műtét előtt az MHS-vizsgálatot. A szövettani mintavétel 166 betegnél történt meg. Eredmények: A citológiai vizsgálatot (az összes betegre tekintve) magas álpozitív arány jellemezte (69,28%), amely megfigyelések mindenképpen utalnak az újabb komponens alkalmazásának igényére a triázsban. Az összes citológiai kategóriára nézve az MHS-eredmények közül kiemelendő az álnegatív leletek rendkívül alacsony aránya (3/166 = 1,8%), mely a HPV-teszt esetén ennél magasabb volt (11/165 = 6,66%). A spektroszkópiás vizsgálat álpozitív aránya ugyanakkor kedvezőtlenebbnek bizonyult (91/166 = 54,81%) a HPV-vizsgálat álpozitív arányánál (40/165 = 24,24%). Az atípusos laphámsejt (ASC-US/ASC-H) citológiai kategória esetén a spektroszkópia álnegatív eredményeinek aránya (3/126 = 2,38%) szintén kedvezőbb volt, mint a HPV-vizsgálaté (9/126 = 7,14%). A cervicalis intraepithelialis neoplasia-2 vagy súlyosabb fokozatú hámelváltozások azonosításában a spektroszkópia szenzitivitása 94% (95% CI = 0,84–0,99), specificitása 22% (95% CI = 0,15–0,31), negatív prediktív értéke 90% (95% CI = 0,73–0,98), pozitív prediktív értéke 34% (95% CI = 0,26–0,43) volt (p = 0,00130). Következtetés: Az MHS fejlett innovatív technológián alapuló, azonnali eredményt adó vizsgálóeljárás, amely kiemelkedően alacsony álnegatív eredménye miatt nagy segítséget nyújt a citológiai eltéréssel rendelkező betegek további vizsgálatában. Orv Hetil. 2021; 162(20): 790–799. Summary. Introduction: Despite the use of human papillomavirus (HPV) testing, the management of the transitional categories of cytology-based screening still remains a challenge. The modern multimodal hyperspectroscopy (MHS) of the cervix is a novel digital technology based on artificial intelligence, providing an instant result in the assessment of cytology-based screening abnormalities. Patients and methods: 208 women (age 18–75) were enrolled. The patients already had cytology results and an operation on the cervix indicated at the time of inclusion. HPV and the hyperspectroscopy examination was performed pre-operatively. The pre-indicated operation was performed on 166 patients. Results: Cytology-based screening alone (in the category of all patients) resulted in a high false-positive rate (69.28%). In this category, the MHS had an outstanding false-negative rate (3/166 = 1.80%) compared to the HPV (11/165 = 6.66%). The false-positive rate of the spectroscopy examination (91/166 = 54.81%) was higher than that of the HPV testing (40/165 = 24.24%). In the atypical squamous cell (ASC-US/ASC-H) category, the false-negative rate of the spectroscopy (3/126 = 2.38%) was also lower than that of the HPV test (9/126 = 7.14%). In the detection of high-grade abnormalities (cervical intraepithelial neoplasia 2 and worse), the spectroscopy had a 94% sensitivity (95% CI = 0.84–0.99), with a 22% specificity (95% CI = 0.15–0.31), an 90% negative predictive value (95% CI = 0.73–0.98), and a 34% positive predictive value (95% CI = 0.26–0.43) (p = 0.00130). Conclusion: In the case of cytological abnormality, the MHS provides an immediate result based on advanced digital technology, and because of its outstanding false negative rate it is a great aid and should be considered in the triage of such patients. Orv Hetil. 2021; 162(20): 790–799.


2020 ◽  
Vol 4 (Supplement_1) ◽  
pp. 259-260
Author(s):  
Laura Curtis ◽  
Lauren Opsasnick ◽  
Julia Yoshino Benavente ◽  
Cindy Nowinski ◽  
Rachel O’Conor ◽  
...  

Abstract Early detection of Cognitive impairment (CI) is imperative to identify potentially treatable underlying conditions or provide supportive services when due to progressive conditions such as Alzheimer’s Disease. While primary care settings are ideal for identifying CI, it frequently goes undetected. We developed ‘MyCog’, a brief technology-enabled, 2-step assessment to detect CI and dementia in primary care settings. We piloted MyCog in 80 participants 65 and older recruited from an ongoing cognitive aging study. Cases were identified either by a documented diagnosis of dementia or mild cognitive impairment (MCI) or based on a comprehensive cognitive battery. Administered via an iPad, Step 1 consists of a single self-report item indicating concern about memory or other thinking problems and Step 2 includes two cognitive assessments from the NIH Toolbox: Picture Sequence Memory (PSM) and Dimensional Change Card Sorting (DCCS). 39%(31/80) participants were considered cognitively impaired. Those who expressed concern in Step 1 (n=52, 66%) resulted in a 37% false positive and 3% false negative rate. With the addition of the PSM and DCCS assessments in Step 2, the paradigm demonstrated 91% sensitivity, 75% specificity and an area under the ROC curve (AUC)=0.82. Steps 1 and 2 had an average administration time of &lt;7 minutes. We continue to optimize MyCog by 1) examining additional items for Step 1 to reduce the false positive rate and 2) creating a self-administered version to optimize use in clinical settings. With further validation, MyCog offers a practical, scalable paradigm for the routine detection of cognitive impairment and dementia.


1989 ◽  
Vol 75 (2) ◽  
pp. 156-162 ◽  
Author(s):  
Sandro Sulfaro ◽  
Francesco Querin ◽  
Luigi Barzan ◽  
Mario Lutman ◽  
Roberto Comoretto ◽  
...  

Sixty-six whole-organ sectioned laryngopharyngectomy specimens removed for cancer during a seven-year period were uniformly examined to determine the accuracy of preoperative high resolution computerized tomography (CT) for detection of cartilaginous involvement. Our results indicate that CT has a high overall specificity (88.2%) but a low sensitivity (47.1 %); we observed a high false-negative rate (26.5%) and a fairly low false-positive rate (5.9%). Massive cartilage destruction was easily assessed by CT, whereas both small macroscopic and microscopic neoplastic foci of cartilaginous invasion were missed on CT scans. Moreover, false-positive cases were mainly due to proximity of the tumor to the cartilage. Clinical implications of these results are discussed.


2020 ◽  
Vol 15 (1) ◽  
Author(s):  
Shintaro Sukegawa ◽  
Sawako Ono ◽  
Keisuke Nakano ◽  
Kiyofumi Takabatake ◽  
Hotaka Kawai ◽  
...  

Abstract Background This study was conducted to compare the histological diagnostic accuracy of conventional oral-based cytology and liquid-based cytology (LBC) methods. Methods Histological diagnoses of 251 cases were classified as negative (no malignancy lesion, inflammation, or mild/moderate dysplasia) and positive [severe dysplasia/carcinoma in situ (CIS) and squamous cell carcinoma (SCC)]. Cytological diagnoses were classified as negative for intraepithelial lesion or malignancy (NILM), oral low-grade squamous intraepithelial lesion (OLSIL), oral high-grade squamous intraepithelial lesion (OHSIL), or SCC. Cytological diagnostic results were compared with histology results. Results Of NILM cytology cases, the most frequent case was negative [LBC n = 50 (90.9%), conventional n = 22 (95.7%)]. Among OLSIL cytodiagnoses, the most common was negative (LBC n = 34; 75.6%, conventional n = 14; 70.0%). Among OHSIL cytodiagnoses (LBC n = 51, conventional n = 23), SCC was the most frequent (LBC n = 31; 60.8%, conventional n = 7; 30.4%). Negative cases were common (LBC n = 13; 25.5%, conventional n = 14; 60.9%). Among SCC cytodiagnoses SCC was the most common (LBC n = 16; 88.9%, conventional n = 14; 87.5%). Regarding the diagnostic results of cytology, assuming OHSIL and SCC as cytologically positive, the LBC method/conventional method showed a sensitivity of 79.4%/76.7%, specificity of 85.1%/69.2%, false-positive rate of 14.9%/30.7%, and false-negative rate of 20.6%/23.3%. Conclusions LBC method was superior to conventional cytodiagnosis methods. It was especially superior for OLSIL and OHSIL. Because of the false-positive and false-negative cytodiagnoses, it is necessary to make a comprehensive diagnosis considering the clinical findings.


2020 ◽  
Author(s):  
Shintaro Sukegawa ◽  
Sawako Ono ◽  
Keisuke Nakano ◽  
Kiyofumi Takabatake ◽  
Hotaka Kawai ◽  
...  

Abstract BackgroundThis study was conducted to compare the histological diagnostic accuracy of conventional oral-based cytology and liquid-based cytology (LBC) methods.MethodsHistological diagnoses of 251 cases were classified as negative (no malignancy lesion, inflammation, or mild/moderate dysplasia) and positive [severe dysplasia/carcinoma in situ (CIS) and squamous cell carcinoma (SCC)]. Cytological diagnoses were classified as negative for intraepithelial lesion or malignancy (NILM), oral low-grade squamous intraepithelial lesion (OLSIL), oral high-grade squamous intraepithelial lesion (OHSIL), or SCC. Cytological diagnostic results were compared with histology results.ResultsOf NILM cytology cases, the most frequent case was negative [LBC n = 50 (90.9%), conventional n = 22 (95.7%)]. Among OLSIL cytodiagnoses, the most common was negative (LBC n = 34; 75.6%, conventional n = 14; 70.0%). Among OHSIL cytodiagnoses (LBC n = 51, conventional n = 23), SCC was the most frequent (LBC n = 31; 60.8%, conventional n = 7; 30.4%). Negative cases were common (LBC n = 13; 25.5%, conventional n = 14; 60.9%). Among SCC cytodiagnoses SCC was the most common (LBC n = 16; 88.9%, conventional n = 14; 87.5%). Regarding the diagnostic results of cytology, assuming OHSIL and SCC as cytologically positive, the LBC method/conventional method showed a sensitivity of 79.4%/76.7%, specificity of 85.1%/69.2%, false-positive rate of 14.9%/30.7%, and false-negative rate of 20.6%/23.3%.ConclusionsLBC method was superior to conventional cytodiagnosis methods. It was especially superior for OLSIL and OHSIL. Because of the false-positive and false-negative cytodiagnoses, it is necessary to make a comprehensive diagnosis considering the clinical findings.


PLoS ONE ◽  
2021 ◽  
Vol 16 (2) ◽  
pp. e0246438
Author(s):  
Akihiro Shitara ◽  
Kazumasa Takahashi ◽  
Mayumi Goto ◽  
Harunori Takahashi ◽  
Takuya Iwasawa ◽  
...  

This prospective study evaluated the accuracy of non-invasive preimplantation genetic testing for aneuploidy (niPGT-A) using cell-free DNA in spent culture medium, as well as that of preimplantation genetic testing for aneuploidy (PGT-A) using trophectoderm (TE) biopsy after culturing beyond implantation. Twenty frozen blastocysts donated by 12 patients who underwent IVF at our institution were investigated. Of these, 10 were frozen on day 5 and 10 on day 6. Spent culture medium and TE cells were collected from each blastocyst after thawing, and the embryos were cultured in vitro for up to 10 days. The outgrowths after culturing beyond implantation were sampled and subjected to chromosome analysis using next-generation sequencing. Chromosomal concordance rate, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), false-positive rate (FPR), and false-negative rate (FNR) of niPGT-A and PGT-A against each outgrowth were analyzed. The concordance rate between the niPGT-A and outgrowth samples was 9/16 (56.3%), and the concordance rate between the PGT-A and outgrowth samples was 7/16 (43.8%). NiPGT-A exhibited 100% sensitivity, 87.5% specificity, 88.9% PPV, 100% NPV, 12.5% FPR, and 0% FNR. PGT-A exhibited 87.5% sensitivity, 77.8% specificity, 87.5% PPV, 75% NPV, 14.3% FPR, and 22.2% FNR. NiPGT-A may be more accurate than PGT-A in terms of ploidy diagnostic accuracy in outgrowths.


2020 ◽  
Author(s):  
Shintaro Sukegawa ◽  
Sawako Ono ◽  
Keisuke Nakano ◽  
Kiyofumi Takabatake ◽  
Hotaka Kawai ◽  
...  

Abstract Background This study was conducted to compare histological diagnostic accuracy between conventional method and liquid-based cytology (LBC) method and to clarify the effectiveness of cytology. Methods Histological diagnoses of 251 cases were classified as negative (no malignancy lesion, inflammation, and mild/moderate dysplasia) and positive [oral intraepithelial neoplasia/carcinoma in situ (OIN/CIS) and squamous cell carcinoma (SCC)]. Cytological diagnoses were classified as negative for intraepithelial lesion or malignancy (NILM), oral low-grade squamous intraepithelial lesion (OLSIL), oral high-grade squamous intraepithelial lesion (OHSIL), or SCC. Cytological diagnostic results were compared with histology results. Results Of NILM cytology cases, the most frequent case was negative [LBC n = 50 (90.9%), conventional n = 22 (95.7%)]. Among OLSIL cytodiagnoses, the most common was negative (LBC n = 34; 75.6%, conventional n = 14; 70.0%). Among OHSIL cytodiagnoses (LBC n = 51, conventional n = 23), SCC was the most frequent (LBC n = 31; 60.8%, conventional n = 7; 30.4%). Negative cases were common (LBC n = 13; 25.5%, conventional n = 14; 60.9%). Among SCC cytodiagnoses SCC was the most common (LBC n = 16; 88.9%, conventional n = 14; 87.5%). Regarding the diagnostic results of cytology, assuming HSIL and SCC as cytologically positive, the LBC method/conventional method showed a sensitivity of 79.4%/76.7%, specificity of 85.1%/69.2%, false positive rate of 14.9%/30.7%, and false negative rate of 20.6%/23.3%. Conclusions LBC method was superior to conventional method in cytodiagnosis. It was especially superior for LSIL and HSIL. Because of the false positive and false negative cytodiagnoses, it is necessary to make a comprehensive diagnosis considering the clinical findings.