scholarly journals Dosimetric evaluation of the heart and left anterior descending artery dose in radiotherapy for Japanese patients with breast cancer

2019 ◽  
Vol 61 (1) ◽  
pp. 134-139
Author(s):  
Osamu Tanaka ◽  
Kousei Ono ◽  
Takuya Taniguchi ◽  
Chiyoko Makita ◽  
Masayuki Matsuo

Abstract Intensity-modulated radiotherapy (IMRT) has been used for breast cancer as well as in field-in-field techniques. Few dosimetric comparison studies have been conducted using IMRT and volumetric modulated arc therapy (VMAT) for Japanese patients. We aimed to study such patients. Thirty-two patients with left-sided breast cancer were enrolled. We conducted the following five treatment plans: two field-static IMRT (2F-S-IMRT), four field-static IMRT (4F-S-IMRT), 40° dual partial arc VMAT (40d-VMAT), 80° dual partial arc VMAT (80d-VMAT) and 210° partial VMAT (210p-VMAT). We evaluated the following: level of coverage of planning target volume (PTV) of 95% for irradiation at a dose of 50 Gy (D95) and the percentage of the heart and left anterior descending artery (LAD) volume that received 10 Gy or more (V10). As a result, the coverage of 40d-VMAT for the prescribed PTV dose of D95 was significantly lower than that of the other treatment plans (P < 0.05). Regarding heart V10 and LAD V10, 2F-S-IMRT, 40d-VMAT and 80d-VMAT showed significantly lower dose than the other treatment plans (P < 0.05). In conclusion, among the five plans, 2F-S-IMRT is recommended for Japanese patients because of high coverage of D95 of PTV, low V10 of the heart and LAD and the monitor unit value was the lowest.

Author(s):  
Dean Wilkinson ◽  
Kelly Mackie ◽  
Dean Novy ◽  
Frances Beaven ◽  
Joanne McNamara ◽  
...  

Abstract Introduction: The Pinnacle3 Auto-Planning (AP) package is an automated inverse planning tool employing a multi-sequence optimisation algorithm. The nature of the optimisation aims to improve the overall quality of radiotherapy plans but at the same time may produce higher modulation, increasing plan complexity and challenging linear accelerator delivery capability. Methods and materials: Thirty patients previously treated with intensity-modulated radiotherapy (IMRT) to the prostate with or without pelvic lymph node irradiation were replanned with locally developed AP techniques for step-and-shoot IMRT (AP-IMRT) and volumetric-modulated arc therapy (AP-VMAT). Each case was also planned with VMAT using conventional inverse planning. The patient cohort was separated into two groups, those with a single primary target volume (PTV) and those with dual PTVs of differing prescription dose levels. Plan complexity was assessed using the modulation complexity score. Results: Plans produced with AP provided equivalent or better dose coverage to target volumes whilst effectively reducing organ at risk (OAR) doses. For IMRT plans, the use of AP resulted in a mean reduction in bladder V50Gy by 4·2 and 4·7 % (p ≤ 0·01) and V40Gy by 4·8 and 11·3 % (p < 0·01) in the single and dual dose level cohorts, respectively. For the rectum, V70Gy, V60Gy and V40Gy were all reduced in the dual dose level AP-VMAT plans by an average of 2·0, 2·7 and 7·3 % (p < 0·01), respectively. A small increase in plan complexity was observed only in dual dose level AP plans. Findings: The automated nature of AP led to high quality treatment plans with improvement in OAR sparing and minimised the variation in achievable dose planning metrics when compared to the conventional inverse planning approach.


2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Jian Hu ◽  
Guang Han ◽  
Yu Lei ◽  
Ximing Xu ◽  
Wei Ge ◽  
...  

Introduction. This study is aimed at evaluating the dosimetric differences among target segmented planning (TSP), conventional 9-field intensity modulated radiation therapy (9FIMRT) planning, and volumetric modulated arc therapy (VMAT) planning for postmastectomy radiotherapy of left-sided breast cancer patients. Material and Methods. Fifteen left-sided breast cancer patients who underwent radical mastectomy were enrolled. In TSP, the planning target volume (PTV) was divided into four regions (supra/infraclavicular, chest wall, external mammary region, and internal mammary region), and each individual PTV region was treated with respective fixed fields. Results. The VMAT plans showed superior to PTV dose conformity index (CI), homogeneity index (HI), protection of the ipsilateral lung, monitor units (MUs), and maximum dose (Dmax) to the contralateral breast compared with TSP and 9FIMRT plans. The TSP provided better protection for Dmean of the heart and left ventricle (p<0.05). A dose for left anterior descending artery from the three techniques had no significant difference. Compared with the 9FIMRT plans, the V5Gy (%) and V10Gy (%) for the ipsilateral lung were significantly reduced with TSP and VMAT (p<0.05). The V5Gy (%) and V10Gy (%) for the ipsilateral lung turned out to be similar between VMAT and TSP techniques. Conclusions. Our study indicates that VMAT should be a better choice of radiotherapy for left-sided breast cancer patients after radical mastectomy. If VMAT is unavailable, 9FIMRT can achieve better CI and HI values and be more MU-efficient compared with TSP; however, TSP can effectively reduce the low dose volume of the ipsilateral lungs and heart.


2017 ◽  
Vol 16 (3) ◽  
pp. 272-279
Author(s):  
Steven B. D. Murphy ◽  
Heather Drury-Smith

AbstractBackground and purposeTo determine which concomitant boost technique is dosimetrically superior in the treatment of breast cancer; volumetric-modulated arc therapy (VMAT) or fixed field intensity-modulated radiotherapy (ff-IMRT).Materials and methodsIn total, 30 breast patients were re-planned with both VMAT and fixed field concomitant boost intensity-modulated radiotherapy techniques. A hybrid technique was used delivering 80% of the dose through tangential beams and 20% through an integrated boost. A two-tailed t-test sample for means was used to compare the dosimetric differences between the techniques.ResultsMaximum dose was statistically lower for VMAT; 103·2 versus 103·7% for ff-IMRT along with statistically lower V2 Gy doses to the contralateral lung (0·7 versus 1·6%) and heart for both left- (19·0%/22·6%), and right- (5·5%/8·8%) sided patients, respectively. ff-IMRT boasted significantly lower ipsilateral lung V20, V18 and V10 Gy (7·9/8·6/13·1 versus 8·1/8·8/13·4%) than VMAT, respectively. No differences were found with minimum coverage, mean dose and V5 Gy to all organs at risk (OARs).ConclusionVMAT and ff-IMRT techniques demonstrate excellent target coverage and OAR sparing facilitated by the hybrid planning technique and deep inspiration breath hold. There is no obvious dosimetrically superior option between the two techniques. Reduced treatment times with VMAT make it more desirable to implement clinically.


Author(s):  
Karthikeyan Kalyanasundaram ◽  
Subramani Vellaiyan

Abstract Purpose: The purpose of the study was to evaluate the impact of changes in breathing pattern inside the breath-hold window (BHW) during deep inspiration breath hold treatment for carcinoma left breast patients post-conservative surgery. Methods: Ten patients of carcinoma left breast post-conservative surgery were prospectively selected. Three sets of CT plain images were acquired, one with 5 mm deep inspiration BHW (DIBHR) and the other one with 1 mm BHW matching the lower threshold (DIBHL) and the third one with 1 mm BHW matching the upper threshold (DIBHH) as DIBHR. For all patients, forward intensity-modulated radiotherapy (FIMRT) and volumetric modulated arc therapy (VMAT) plans were generated in the 5 mm BHW CT series and the same plan being copy and pasted in other series. Target volume doses and critical structure doses were tabulated. Results: Planning target volume coverage was adequate and no significant differences were found in any CT series. Significant differences noted in average left lung V5%, V10% and V18% doses between DIBHR versus DIBHH (p values = 0·0461, 0·0283 and 0·0213, respectively) and DIBHL versus DIBHH (p values = 0·0434, 0·0484 and 0·0334, respectively) for FIMRT plans and V18% doses in DIBHR versus DIBHH (p = 0·0067) in VMAT. No differences in heart and apex of heart doses were found. Left anterior descending artery (LAD) mean doses were significant in DIBHL versus DIBHR, DIBHR versus DIBHH and DIBHL versus DIBHH (p = 0·0012, 0·0444 and 0·0048, respectively) series for FIMRT plans and DIBHR versus DIBHH and DIBHL versus DIBHH (p = 0·0341, 0·0001) for VMAT plans. Finding: The changes in the breathing pattern inside DIBH window level cause some variation in LAD doses and no other significant differences in any parameters noted, so care should be taken while treating patients with preexisting cardiac conditions.


2015 ◽  
Vol 103 (5) ◽  
pp. 438-442
Author(s):  
Ayşe Hiçsönmez ◽  
Yıldız Güney ◽  
Ayşen Dizman ◽  
Bahar Dirican ◽  
Yakup Arslan ◽  
...  

Aims The purpose of this study is to calculate the treatment plans and to compare the dose distributions and dose-volume histograms (DVH) for 6 external radiotherapy techniques for the treatment of retinoblastoma as well as intensity-modulated radiotherapy (IMRT) and fractionated stereotactic radiotherapy (Cyberknife). Methods Treatment plans were developed using 6 techniques, including an en face electron technique (ET), an anterior and lateral wedge photon technique (LFT), a 3D conformal (6 fields) technique (CRT), an inverse plan IMRT, tomotherapy, and conventional focal stereotactic external beam radiotherapy with Cyberknife (SBRT). Dose volume analyses were carried out for each technique. Results All techniques except electron provided similar target coverage. When comparing conformal plan with IMRT and SBRT, there was no significant difference in planning target volume dose distribution. The mean volume of ipsilateral bony orbit received more than 20 Gy, a suggested threshold for bone growth inhibition. The V20 Gy was 73% for the ET, 57% for the LFT, 87% for the CRT, 65% for the IMRT, 66% for the tomotherapy, and 2.7% for the SBRT. Conclusions This work supports the potential use of IMRT and SBRT to spare normal tissues in these patients.


2021 ◽  
Vol 18 (2) ◽  
Author(s):  
Magdalena Charmacińska ◽  
Sara Styś ◽  
Olga Bąk ◽  
Weronika Kijeska ◽  
Agnieszka Skrobała

Nowotwór piersi jest to nowotwór złośliwy powstający z komórek gruczołu piersiowego, który rozwija się miejscowo w piersi oraz daje przerzuty do węzłów chłonnych i narządów wewnętrznych (płuc, wątroby, kości i mózgu). Ponad 23% zachorowań na nowotwory kobiet w Polsce, jak i na świecie stanowią nowotwory piersi. Na przestrzeni ostatnich lat techniki napromieniania nowotworów piersi ulegają ciągłemu rozwojowi. Celem pracy było poglądowe przedstawienie technik radioterapeutycznych stosowanych w napromienianiu nowotworów piersi, od dwuwymiarowej 2D techniki statycznej poprzez techniki dynamiczne (IMRT technika z modulacją intensywnością dawki (ang. intensity modulated radiation therapy), VMAT technika obrotowa z modulacją intensywności dawki (ang. volumetric modulated arc therapy), aż do techniki DIBH techniki napromieniania na głębokim wstrzymanym wdechu (ang. deep inspiration breath hold). W pracy skupiono się na przedstawieniu realizacji omawianych technik i opisie jak dana technika wpływa na rozkład dawki w planowanej objętości do napromieniania PTV (ang. Planning Target Volume) oraz na dawki w narządach krytycznych w radioterapii nowotworów piersi.


2021 ◽  
Vol 55 (4) ◽  
pp. 499-507
Author(s):  
Yuan Xu ◽  
Pan Ma ◽  
Zhihui Hu ◽  
Yuan Tian ◽  
Kuo Men ◽  
...  

Abstract Background Non-coplanar volumetric modulated arc therapy (ncVMAT) is proposed to reduce toxicity in heart and lungs for locoregional radiotherapy of left-sided breast cancer, including internal mammary nodes (IMN). Patients and methods This retrospective study included 10 patients with left-sided breast cancer who underwent locoregional radiotherapy after breast-conserving surgery. For each patient, the ncVMAT plan was designed with four partial arcs comprising two coplanar arcs and two non-coplanar arcs, with a couch rotating to 90°. The prescribed dose was normalized to cover 95% of planning target volume (PTV), with 50 Gy delivered in 25 fractions. For each ncVMAT plan, dosimetric parameters were compared with the coplanar volumetric modulated arc therapy (coV-MAT) plan. Results T here were improvements in conformity index, homogeneity index and V55 of total target volume (PTVall) comparing ncVMAT to coVMAT (p < 0.001). Among the organs at risk, the average V30, V20, V10, V5, and mean dose (Dmean) of the heart decreased significantly (p < 0.001). Furthermore, ncVMAT significantly reduced the mean V20, V10, V5, and Dmean of left lung and the mean V10 and V5 and Dmean of contralateral lung (p < 0.001). An improved sparing of the left anterior descending coronary artery and right breast were also observed with ncVMAT (p < 0.001). Conclusions Compared to coVMAT, ncVMAT provides improved conformity and homogeneity of whole P TV, better dose sparing of the heart, bilateral lungs, left anterior descending coronary artery (LAD), and right breast for locoregional radiotherapy of left-sided breast cancer with IMN, potentially reducing the risk of normal tissue damage.


2019 ◽  
Vol 37 (15_suppl) ◽  
pp. e15505-e15505
Author(s):  
Lu Wang ◽  
Jinming Yu

e15505 Background: Based on dosimetry and radiobiology to compare treatment plans for esophageal cancer (EC) in different location using intensity modulated radiotherapy (IMRT), volumetric modulated arc radiotherapy (VMAT) and helical tomotherapy(HT) with simultaneous integrated boost (SIB) technique. Methods: A total of 20 patients including 5 cases respectively located in the cervix, upper, middle and lower thorax were generated for IMRT, VMAT and HT plans. The dose volume histogram statistics, conformity index (CI), homogeneity index (HI), tumor control probability (TCP) and normal tissues control probability (NTCP) were analyzed to evaluate treatment plans. Results: HT showed significantly improvement over IMRT and VMAT in terms of CI(0.93±0.03), HI(0.07±0.03) and TCP(88.08±0.82%) in cervical EC(p<0.05). IMRT greatly developed TCP(88.29±1.79%;85.11±0.79%), and offered superior CIs (0.87±0.04;0.90±0.01) and HIs(0.10±0.01; 0.06±0.01) compared with VMAT and HT in upper and middle thoracic EC(p<0.05). Meanwhile, the V30(33.30±6.49%), mean dose (2559.00±219.64cGy) and NTCP(0.50±0.61%) of heart for IMRT were significantly reduced than other two techniques in middle thoracic EC. Patients with lower thoracic EC yielded the similar CIs and HIs(all p>0.05) for the 3 techniques, but VMAT showed the lowest NTCP of lungs (0.01±0.01%) with improved TCP (84.84±1.13%). Conclusions: HT was a good option with little lung and heart involvement as it achieved superior dose conformality and uniformity. IMRT was a perfect strategy with large thoracic involvement. It significantly improved tumor local control and reduced heart dose and complications with acceptable dose to lungs. VMAT was preferred with a smaller target volume but surrounded by more heart and less lungs. Individually choosing optimal technique for EC in different location will be warranted.