DETERMINATION OF THE BEST ANKLE BRACHIAL INDEX THRESHOLD VALUES FOR THE ROUTINE DETECTION OF A SIGNIFICANT LOWER LIMB ARTERIAL STENOSIS USING AN AUTOMATED DEVICE

2011 ◽  
Vol 29 ◽  
pp. e481
Author(s):  
D. Rosenbaum ◽  
S. Rodriguez-Carranza ◽  
P. Laroche ◽  
E. Bruckert ◽  
P. Giral ◽  
...  
2011 ◽  
Vol 5 (4) ◽  
pp. 180
Author(s):  
D. Rosenbaum ◽  
S. Rodriguez Carranza ◽  
P. Laroche ◽  
P. Giral ◽  
E. Bruckert ◽  
...  

2013 ◽  
Vol 2013 ◽  
pp. 1-10
Author(s):  
Xiaoyun Li ◽  
Ling Wang ◽  
Chi Zhang ◽  
Shuyu Li ◽  
Fang Pu ◽  
...  

The ankle-brachial index (ABI), defined as the ratio of systolic pressure in the ankle arteries and that in the brachial artery, was a useful noninvasive method to detect arterial stenoses. There had been a lot of researches about clinical regularities of ABI; however, mechanism studies were less addressed. For the purpose of a better understanding of the correlation between vascular stenoses and ABI, a computational model for simulating blood pressure and flow propagation in various arterial stenosis circumstances was developed with a detailed compartmental description of the heart and main arteries. Particular attention was paid to the analysis of effects of vascular stenoses in different large-sized arteries on ABI in theory. Moreover, the variation of ABI during the increase of the stenosis severity was also studied. Results showed that stenoses in lower limb arteries, as well as, brachial artery, caused different variations of blood pressure in ankle and brachial arteries, resulting in a significant change of ABI. Furthermore, the variation of ABI became faster when the severity of the stenosis increased, validating that ABI was more sensitive to severe stenoses than to mild/moderate ones. All these in findings revealed the reason why ABI was an effective index for detecting stenoses, especially in lower limb arteries.


VASA ◽  
2012 ◽  
Vol 41 (4) ◽  
pp. 275-281 ◽  
Author(s):  
da Rocha Chehuen ◽  
G. Cucato ◽  
P. dos Anjos Souza Barbosa ◽  
A. R. Costa ◽  
M. Ritti-Dias ◽  
...  

Background: This study assessed the relationship between lower limb hemodynamics and metabolic parameters with walking tolerance in patients with intermittent claudication (IC). Patients and methods: Resting ankle-brachial index (ABI), baseline blood flow (BF), BF response to reactive hyperemia (BFRH), oxygen uptake (VO2), initial claudication distance (ICD) and total walking distance (TWD) were measured in 28 IC patients. Pearson and Spearman correlations were calculated. Results: ABI, baseline BF and BF response to RH did not correlate with ICD or TWD. VO2 at first ventilatory threshold and VO2peak were significantly and positively correlated with ICD (r = 0.41 and 0.54, respectively) and TWD (r = 0.65 and 0.71, respectively). Conclusions: VO2peak and VO2 at first ventilatory threshold, but not ABI, baseline BF and BFHR were associated with walking tolerance in IC patients. These results suggest that VO2 at first ventilatory threshold may be useful to evaluate walking tolerance and improvements in IC patients.


1997 ◽  
Vol 54 (spe) ◽  
pp. 155-164 ◽  
Author(s):  
R.T. de Faria ◽  
M.V. Folegatti ◽  
J.A. Frizzone ◽  
A.M. Saad

The economical benefits of different irrigation strategies were assessed by long term simulation (20 years) for dry beans in Paraná, Brazil. The model BEANGRO was used to simulate crop yield and irrigation requirements assuming eight levels of irrigation threshold (20 to 90% of the remaining soil available water in steps of 10%), in addition to a level considering no irrigation. Net return was the objective function to select the optimum irrigation management strategy, assuming fixed and stochastic distributions of historical product price. The results showed that yield was significantly increased by irrigation despite a high variability for all the simulation strategies, due to variations on growth conditions over the years. Although the net return was highly variable, it was positive in 75% of the years for all strategies with threshold values higher than 30%. The strategy of irrigating the crop before the soil reaches 60% AW provided the maximum economical benefits. The high profit using this improved strategy justifies the practice of irrigation for beans in Paraná.


2018 ◽  
Vol 80 (3) ◽  
pp. 290-292
Author(s):  
Jinyan Mu ◽  
Dan Liu ◽  
Daihong Ji ◽  
Borui Li ◽  
Zhigang Li ◽  
...  

2020 ◽  
pp. 112972982093241
Author(s):  
Shek Yin Au ◽  
Kwong Shun Chan ◽  
Ka Man Fong ◽  
Sai Kwong Yung ◽  
Wing Yiu George Ng ◽  
...  

Termination of peripheral veno-arterial extracorporeal membrane oxygenation support by managing the arteriotomy wound using a percutaneous closure device was reported successful and effective. However, careful assessment by clinical examination and also ultrasound Doppler assessment of the lower limb vasculature after closure is of paramount importance. Complications including pseudoaneurysm, arterial stenosis, and acute thrombosis are not uncommon. In this case report, commercial microbubbles were used as ultrasound contrast to enhance the image quality for better vascular ultrasound and Doppler assessment after veno-arterial extracorporeal membrane oxygenation percutaneous decannulation. A peudoaneurysm was revealed after microbubble injection, which would otherwise be missed.


Sign in / Sign up

Export Citation Format

Share Document