Are True-Negative Nitrite Results Affected by a Two-Hour Delay in Dipstick/Pad Analysis of Urine in Incontinence Pads?

2006 ◽  
Vol 33 (3) ◽  
pp. 292-295 ◽  
Author(s):  
Susan Midthun ◽  
A. Wayne Bruce
1978 ◽  
Vol 17 (06) ◽  
pp. 249-253
Author(s):  
E. Pétursson ◽  
B. Sigurbjörnsson ◽  
D. Davidsson ◽  
O.G. Björnsson

A 3-year follow-up and re-evaluation of all scans on all patients referred for brain scanning in Iceland during 1 year was performed in order to assess the diagnostic reliability of radioisotope scanning for brain tumours. The study included 471 patients. Of these 25 had primary brain tumours and 7 brain metastases. Scans were positive and correctly interpreted in68 % of the patients with primary brain tumours and in 3 of the 7 patients with metastases. The over-all accuracy of brain scanning for brain tumours defined as the total number of correct positive scans and correct negative scans versus total number of scans examined was 96%, this figure being mainly influenced by the high number of true negative scans.


2020 ◽  
Vol 41 (4) ◽  
pp. 240-247
Author(s):  
Lei Yang ◽  
Qingtao Zhao ◽  
Shuyu Wang

Background: Serum periostin has been proposed as a noninvasive biomarker for asthma diagnosis and management. However, its accuracy for the diagnosis of asthma in different populations is not completely clear. Methods: This meta-analysis aimed to evaluate the diagnostic accuracy of periostin level in the clinical determination of asthma. Several medical literature data bases were searched for relevant studies through December 1, 2019. The numbers of patients with true-positive, false-positive, false-negative, and true-negative results for the periostin level were extracted from each individual study. We assessed the risk of bias by using Quality Assessment of Diagnostic Accuracy Studies 2. We used the meta-analysis to produce summary estimates of accuracy. Results: In total, nine studies with 1757 subjects met the inclusion criteria. The pooled estimates of sensitivity, specificity, and diagnostic odds ratios for the detection of asthma were 0.58 (95% confidence interval [CI], 0.38‐0.76), 0.86 (95% CI, 0.74‐0.93), and 8.28 (95% CI, 3.67‐18.68), respectively. The area under the summary receiver operating characteristic curve was 0.82 (95% CI, 0.79‐0.85). And significant publication bias was found in this meta‐analysis (p = 0.39). Conclusion: Serum periostin may be used for the diagnosis of asthma, with moderate diagnostic accuracy.


2020 ◽  
Vol 32 (3) ◽  
pp. 423-431 ◽  
Author(s):  
Hiroki Ushirozako ◽  
Go Yoshida ◽  
Tomohiko Hasegawa ◽  
Yu Yamato ◽  
Tatsuya Yasuda ◽  
...  

OBJECTIVETranscranial motor evoked potential (TcMEP) monitoring may be valuable for predicting postoperative neurological complications with a high sensitivity and specificity, but one of the most frequent problems is the high false-positive rate. The purpose of this study was to clarify the differences in the risk factors for false-positive TcMEP alerts seen when performing surgery in patients with pediatric scoliosis and adult spinal deformity and to identify a method to reduce the false-positive rate.METHODSThe authors retrospectively analyzed 393 patients (282 adult and 111 pediatric patients) who underwent TcMEP monitoring while under total intravenous anesthesia during spinal deformity surgery. They defined their cutoff (alert) point as a final TcMEP amplitude of ≤ 30% of the baseline amplitude. Patients with false-positive alerts were classified into one of two groups: a group with pediatric scoliosis and a group with adult spinal deformity.RESULTSThere were 14 cases of false-positive alerts (13%) during pediatric scoliosis surgery and 62 cases of false-positive alerts (22%) during adult spinal deformity surgery. Compared to the true-negative cases during adult spinal deformity surgery, the false-positive cases had a significantly longer duration of surgery and greater estimated blood loss (both p < 0.001). Compared to the true-negative cases during pediatric scoliosis surgery, the false-positive cases had received a significantly higher total fentanyl dose and a higher mean propofol dose (0.75 ± 0.32 mg vs 0.51 ± 0.18 mg [p = 0.014] and 5.6 ± 0.8 mg/kg/hr vs 5.0 ± 0.7 mg/kg/hr [p = 0.009], respectively). A multivariate logistic regression analysis revealed that the duration of surgery (1-hour difference: OR 1.701; 95% CI 1.364–2.120; p < 0.001) was independently associated with false-positive alerts during adult spinal deformity surgery. A multivariate logistic regression analysis revealed that the mean propofol dose (1-mg/kg/hr difference: OR 3.117; 95% CI 1.196–8.123; p = 0.020), the total fentanyl dose (0.05-mg difference; OR 1.270; 95% CI 1.078–1.497; p = 0.004), and the duration of surgery (1-hour difference: OR 2.685; 95% CI 1.131–6.377; p = 0.025) were independently associated with false-positive alerts during pediatric scoliosis surgery.CONCLUSIONSLonger duration of surgery and greater blood loss are more likely to result in false-positive alerts during adult spinal deformity surgery. In particular, anesthetic doses were associated with false-positive TcMEP alerts during pediatric scoliosis surgery. The authors believe that false-positive alerts during pediatric scoliosis surgery, in particular, are caused by “anesthetic fade.”


2019 ◽  
Vol 12 (3) ◽  
pp. 220-228 ◽  
Author(s):  
Laura Evangelista ◽  
Lea Cuppari ◽  
Luisa Bellu ◽  
Daniele Bertin ◽  
Mario Caccese ◽  
...  

Purpose: The aims of the present study were to: 1- critically assess the utility of L-3,4- dihydroxy-6-18Ffluoro-phenyl-alanine (18F-DOPA) and O-(2-18F-fluoroethyl)-L-tyrosine (18F-FET) Positron Emission Tomography (PET)/Computed Tomography (CT) in patients with high grade glioma (HGG) and 2- describe the results of 18F-DOPA and 18F-FET PET/CT in a case series of patients with recurrent HGG. Methods: We searched for studies using the following databases: PubMed, Web of Science and Scopus. The search terms were: glioma OR brain neoplasm and DOPA OR DOPA PET OR DOPA PET/CT and FET OR FET PET OR FET PET/CT. From a mono-institutional database, we retrospectively analyzed the 18F-DOPA and 18F-FET PET/CT of 29 patients (age: 56 ± 12 years) with suspicious for recurrent HGG. All patients underwent 18F-DOPA or 18F-FET PET/CT for a multidisciplinary decision. The final definition of recurrence was made by magnetic resonance imaging (MRI) and/or multidisciplinary decision, mainly based on the clinical data. Results: Fifty-one articles were found, of which 49 were discarded, therefore 2 studies were finally selected. In both the studies, 18F-DOPA and 18F-FET as exchangeable in clinical practice particularly for HGG patients. From our institutional experience, in 29 patients, we found that sensitivity, specificity and accuracy of 18F-DOPA PET/CT in HGG were 100% (95% confidence interval- 95%CI - 81-100%), 63% (95%CI: 39-82%) and 62% (95%CI: 39-81%), respectively. 18F-FET PET/CT was true positive in 4 and true negative in 4 patients. Sensitivity, specificity and accuracy for 18F-FET PET/CT in HGG were 100%. Conclusion: 18F-DOPA and 18F-FET PET/CT have a similar diagnostic accuracy in patients with recurrent HGG. However, 18F-DOPA PET/CT could be affected by inflammation conditions (false positive) that can alter the final results. Large comparative trials are warranted in order to better understand the utility of 18F-DOPA or 18F-FET PET/CT in patients with HGG.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yujing Xin ◽  
Xinyuan Zhang ◽  
Yi Yang ◽  
Yi Chen ◽  
Yanan Wang ◽  
...  

AbstractThis study is the first multi-center non-inferiority study that aims to critically evaluate the effectiveness of HHUS/ABUS in China breast cancer detection. This was a multicenter hospital-based study. Five hospitals participated in this study. Women (30–69 years old) with defined criteria were invited for breast examination by HHUS, ABUS or/and mammography. For BI-RADS category 3, an additional magnetic resonance imaging (MRI) test was provided to distinguish the true negative results from false negative results. For women classified as BI-RADS category 4 or 5, either core aspiration biopsy or surgical biopsy was done to confirm the diagnosis. Between February 2016 and March 2017, 2844 women signed the informed consent form, and 1947 of them involved in final analysis (680 were 30 to 39 years old, 1267 were 40 to 69 years old).For all participants, ABUS sensitivity (91.81%) compared with HHUS sensitivity (94.70%) with non-inferior Z tests, P = 0.015. In the 40–69 age group, non-inferior Z tests showed that ABUS sensitivity (93.01%) was non-inferior to MG sensitivity (86.02%) with P < 0.001 and HHUS sensitivity (95.44%) was non-inferior to MG sensitivity (86.02%) with P < 0.001. Sensitivity of ABUS and HHUS are all superior to that of MG with P < 0.001 by superior test.For all participants, ABUS specificity (92.89%) was non-inferior to HHUS specificity (89.36%) with P < 0.001. Superiority test show that specificity of ABUS was superior to that of HHUS with P < 0.001. In the 40–69 age group, ABUS specificity (92.86%) was non-inferior to MG specificity (91.68%) with P < 0.001 and HHUS specificity (89.55%) was non-inferior to MG specificity (91.68%) with P < 0.001. ABUS is not superior to MG with P = 0.114 by superior test. The sensitivity of ABUS/HHUS is superior to that of MG. The specificity of ABUS/HHUS is non-inferior to that of MG. In China, for an experienced US radiologist, both HHUS and ABUS have better diagnostic efficacy than MG in symptomatic individuals.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1338
Author(s):  
Wojciech Tylman ◽  
Rafał Kotas ◽  
Marek Kamiński ◽  
Paweł Marciniak ◽  
Sebastian Woźniak ◽  
...  

This paper presents a fall risk assessment approach based on a fast mobility test, automatically evaluated using a low-cost, scalable system for the recording and analysis of body movement. This mobility test has never before been investigated as a sole source of data for fall risk assessment. It can be performed in a very limited space and needs only minimal additional equipment, yet provides large amounts of information, as the presented system can obtain much more data than traditional observation by capturing minute details regarding body movement. The readings are provided wirelessly by one to seven low-cost micro-electro-mechanical inertial measurement units attached to the subject’s body segments. Combined with a body model, these allow segment rotations and translations to be computed and for body movements to be recreated in software. The subject can then be automatically classified by an artificial neural network based on selected values in the test, and those with an elevated risk of falls can be identified. Results obtained from a group of 40 subjects of various ages, both healthy volunteers and patients with vestibular system impairment, are presented to demonstrate the combined capabilities of the test and system. Labelling of subjects as fallers and non-fallers was performed using an objective and precise sensory organization test; it is an important novelty as this approach to subject labelling has never before been used in the design and evaluation of fall risk assessment systems. The findings show a true-positive ratio of 85% and true-negative ratio of 63% for classifying subjects as fallers or non-fallers using the introduced fast mobility test, which are noticeably better than those obtained for the long-established Timed Up and Go test.


Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 304
Author(s):  
Giuseppina Biscontini ◽  
Cinzia Romagnolo ◽  
Chiara Cottignoli ◽  
Andrea Palucci ◽  
Fabio Massimo Fringuelli ◽  
...  

Background: to explore the diagnostic accuracy of 18F-Fluciclovine positron-emission tomography (PET) in prostate cancer (PCa), considering both primary staging prior to radical therapy, biochemical recurrence, and advanced setting. Methods: A systematic web search through Embase and Medline was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Studies performed from 2011 to 2020 were evaluated. The terms used were “PET” or “positron emission tomography” or “positron emission tomography/computed tomography” or “PET/CT” or “positron emission tomography-computed tomography” or “PET-CT” and “Fluciclovine” or “FACBC” and “prostatic neoplasms” or “prostate cancer” or “prostate carcinoma”. Only studies reporting about true positive (TP), true negative (TN), false positive (FP) and false negative (FN) findings of 18F-fluciclovine PET were considered eligible. Results: Fifteen out of 283 studies, and 697 patients, were included in the final analysis. The pooled sensitivity for 18F-Fluciclovine PET/CT for diagnosis of primary PCa was 0.83 (95% CI: 0.80–0.86), the specificity of 0.77 (95% CI: 0.74–0.80). The pooled sensitivity for preoperative LN staging was 0.57 (95% CI: 0.39–0.73) and specificity of 0.99 (95% CI: 0.94–1.00). The pooled sensitivity for the overall detection of recurrence in relapsed patients was 0.68 (95% CI: 0.63–0.73), and specificity of 0.68 (95% CI: 0.60–0.75). Conclusion: This meta-analysis showed promising results in term of sensitivity and specificity for 18F-Fluciclovine PET/CT to stage the primary lesion and in the assessment of nodal metastases, and for the detection of PCa locations in the recurrent setting. However, the limited number of studies and the broad heterogeneity in the selected cohorts and in different investigation protocols are limitation affecting the strength of these results.


2021 ◽  
pp. 104259
Author(s):  
Yan Wang ◽  
Jishui Zhang ◽  
Wenqi Song ◽  
Xiaoyi Tian ◽  
Ying Liu ◽  
...  

Author(s):  
Kristina Lång ◽  
Solveig Hofvind ◽  
Alejandro Rodríguez-Ruiz ◽  
Ingvar Andersson

Abstract Objectives To investigate whether artificial intelligence (AI) can reduce interval cancer in mammography screening. Materials and methods Preceding screening mammograms of 429 consecutive women diagnosed with interval cancer in Southern Sweden between 2013 and 2017 were analysed with a deep learning–based AI system. The system assigns a risk score from 1 to 10. Two experienced breast radiologists reviewed and classified the cases in consensus as true negative, minimal signs or false negative and assessed whether the AI system correctly localised the cancer. The potential reduction of interval cancer was calculated at different risk score thresholds corresponding to approximately 10%, 4% and 1% recall rates. Results A statistically significant correlation between interval cancer classification groups and AI risk score was observed (p < .0001). AI scored one in three (143/429) interval cancer with risk score 10, of which 67% (96/143) were either classified as minimal signs or false negative. Of these, 58% (83/143) were correctly located by AI, and could therefore potentially be detected at screening with the aid of AI, resulting in a 19.3% (95% CI 15.9–23.4) reduction of interval cancer. At 4% and 1% recall thresholds, the reduction of interval cancer was 11.2% (95% CI 8.5–14.5) and 4.7% (95% CI 3.0–7.1). The corresponding reduction of interval cancer with grave outcome (women who died or with stage IV disease) at risk score 10 was 23% (8/35; 95% CI 12–39). Conclusion The use of AI in screen reading has the potential to reduce the rate of interval cancer without supplementary screening modalities. Key Points • Retrospective study showed that AI detected 19% of interval cancer at the preceding screening exam that in addition showed at least minimal signs of malignancy. Importantly, these were correctly localised by AI, thus obviating supplementary screening modalities. • AI could potentially reduce a proportion of particularly aggressive interval cancers. • There was a correlation between AI risk score and interval cancer classified as true negative, minimal signs or false negative.


Sign in / Sign up

Export Citation Format

Share Document