Liver Stiffness Detected by Shear Wave Elastography Predicts Esophageal Varices in Cirrhotic Patients

2019 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Jian-Bin Yu ◽  
Hui Xiong ◽  
Xin-Chun Yuan ◽  
Ai-Yun Zhou
2019 ◽  
Vol 51 (12) ◽  
pp. 1706-1712
Author(s):  
Hae Won Yoo ◽  
Young Seok Kim ◽  
Sang Gyune Kim ◽  
Jeong-Ju Yoo ◽  
Soung Won Jeong ◽  
...  

2019 ◽  
Vol 36 (2) ◽  
pp. 95-101
Author(s):  
Nadella Sindhu ◽  
Prakashini Koteshwar ◽  
Shiran Shetty

Objective: To determine the diagnostic ability of the spleen and liver stiffness in predicting the presence of esophageal varices (EVs). Methods: A sample of cirrhotic patients, diagnosed with sonography, was recruited. The cohorts’ liver stiffness (LS) and spleen stiffness (SS) were measured with the Philips’ Elast PQ technique. Platelet count and spleen size were also documented. The endoscopic report was used as the diagnostic gold standard. Singular and combined parameters were assessed to determine the presence of EV using an independent variable t test, area under the receiver operating characteristic curve, and multilogistic regression analysis statistical tests. Results: In predicting the presence of EV, there was a statistically significant difference in means of SS (2.13 ± 0.69 m/s vs. 3.23 ± 1.32 m/s) and LS (2.33 ± 1.20 m/s vs. 3.05 ± 1.4 m/s), as well as discriminating between groups of patients, with and without EV. The ability to diagnostically classify EV with SS and LS was fair while the remaining parameters were deemed poor, using a SS cutoff value of 1.99 m/s. Conclusion: Despite the difference in means, none of the assessed parameters demonstrated a better classification ability than endoscopy. LS and SS were equal in the prediction of EV in these patients. The LS estimate of fibrosis would have grossly predicted the presence of varices. However, the addition of SS, for the estimation of varices, provided no significant benefit.


Author(s):  
Anders Batman Mjelle ◽  
Anesa Mulabecirovic ◽  
Roald Flesland Havre ◽  
Edda Jonina Olafsdottir ◽  
Odd Helge Gilja ◽  
...  

Abstract Purpose Liver elastography is increasingly being applied in screening for and follow-up of pediatric liver disease, and has been shown to correlate well with fibrosis staging through liver biopsy. Because time is of the essence when examining children, we wanted to evaluate if a reliable result can be achieved with fewer acquisitions. Materials and Methods 243 healthy children aged 4–17 years were examined after three hours of fasting. Participants were divided into four age groups: 4–7 years; 8–11 years; 12–14 years and 15–17 years. Both two-dimensional shear wave elastography (2D-SWE; GE Logiq E9) and point shear wave elastography (pSWE; Samsung RS80A with Prestige) were performed in all participants, while transient elastography (TE, Fibroscan) was performed in a subset of 87 children aged 8–17 years. Median liver stiffness measurement (LSM) values of 3, 4, 5, 6, 7, and 8 acquisitions were compared with the median value of 10 acquisitions (reference standard). Comparison was performed for all participants together as well as within every specific age group. We investigated both the intraclass correlation coefficient (ICC) with absolute agreement and all outliers more than 10 %, 20 % or ≥ 0.5 or 1.0 kPa from the median of 10 acquisitions. Results For all three systems there was no significant difference between three and ten acquisitions, with ICCs ≥ 0.97. All systems needed 4 acquisitions to achieve no LSM deviating ≥ 1.0 kPa of a median of ten. To achieve no LSM deviating ≥ 20 % of a median of ten acquisitions, pSWE and TE needed 4 acquisitions, while 2D-SWE required 6 acquisitions. Conclusion Our results contradict recommendations of 10 acquisitions for pSWE and TE and only 3 for 2D-SWE.


2016 ◽  
Vol 25 (4) ◽  
pp. 525-532 ◽  
Author(s):  
Monica Lupșor-Platon ◽  
Radu Badea ◽  
Mirela Gersak ◽  
Anca Maniu ◽  
Ioana Rusu ◽  
...  

There has been great interest in the development of non-invasive techniques for the diagnosis of liver fibrosis in chronic liver diseases, including ultrasound elastographic methods. Some of these methods have already been adequately studied for the non-invasive assessment of diffuse liver diseases. Others, however, such as two-dimensional Shear Wave Elastography (SWE), of more recent appearance, have yet to be validated and some aspects are for the moment incompletely elucidated. This review discusses some of the aspects related to two-dimensional SWE: the examination technique, the examination performance indicators, intra and interobserver agreement and clinical applications. Recommendations for a high-quality examination technique are formulated. Key words:  –  –  – Two-dimensional Shear Wave Elastography. Abbreviations: 2D- SWE: Two-dimensional Shear Wave Elastography; 3D- SWE: Three-dimensional Shear Wave Elastography; AUROC: area under the receiver operating characteristic curves; ARFI Acoustic Radiation Force Impulse Elastography; EFSUMB: European Federation of Societies for Ultrasound in Medicine and Biology; HVPG: hepatic venous pressure gradient; LS: liver stiffness; LR: likelihood ratio; NPV: negative predictive value; PPV: positive predictive value; ROI: region of interest; RT-E: Real Time-Elastography; Se: sensitivity; Sp: specificity; TE: Transient Elastography; US: ultrasound; VM: valid measurement; E: Young’s modulus


Endocrine ◽  
2021 ◽  
Author(s):  
Domenico Corica ◽  
Antonio Bottari ◽  
Tommaso Aversa ◽  
Letteria Anna Morabito ◽  
Selenia Curatola ◽  
...  

2019 ◽  
Vol 45 (2) ◽  
pp. 402-410 ◽  
Author(s):  
Golo Petzold ◽  
Melissa Porsche ◽  
Volker Ellenrieder ◽  
Steffen Kunsch ◽  
Albrecht Neesse

Sign in / Sign up

Export Citation Format

Share Document