scholarly journals Point Shear Wave Elastography of the Spleen in Predicting the Presence of Esophageal Varices in Cirrhosis: Liver Stiffness vs. Spleen Stiffness

2019 ◽  
Vol 36 (2) ◽  
pp. 95-101
Author(s):  
Nadella Sindhu ◽  
Prakashini Koteshwar ◽  
Shiran Shetty

Objective: To determine the diagnostic ability of the spleen and liver stiffness in predicting the presence of esophageal varices (EVs). Methods: A sample of cirrhotic patients, diagnosed with sonography, was recruited. The cohorts’ liver stiffness (LS) and spleen stiffness (SS) were measured with the Philips’ Elast PQ technique. Platelet count and spleen size were also documented. The endoscopic report was used as the diagnostic gold standard. Singular and combined parameters were assessed to determine the presence of EV using an independent variable t test, area under the receiver operating characteristic curve, and multilogistic regression analysis statistical tests. Results: In predicting the presence of EV, there was a statistically significant difference in means of SS (2.13 ± 0.69 m/s vs. 3.23 ± 1.32 m/s) and LS (2.33 ± 1.20 m/s vs. 3.05 ± 1.4 m/s), as well as discriminating between groups of patients, with and without EV. The ability to diagnostically classify EV with SS and LS was fair while the remaining parameters were deemed poor, using a SS cutoff value of 1.99 m/s. Conclusion: Despite the difference in means, none of the assessed parameters demonstrated a better classification ability than endoscopy. LS and SS were equal in the prediction of EV in these patients. The LS estimate of fibrosis would have grossly predicted the presence of varices. However, the addition of SS, for the estimation of varices, provided no significant benefit.

2020 ◽  
pp. 1-2
Author(s):  
Revathy Marimuthu Shanmugam ◽  
Vinay C ◽  
Sathya Gopalasamy ◽  
Chitra Shanmugam

BACKGROUND: Many noninvasive surrogate marker for Portal hypertension or for the presence or grade of esophageal varices were studied..Splenomegaly along with splenic congestion secondary to splenic hyperdynamic circulation is seen secondary to Portal hypertension in cirrhotic patients that can be quantified by elastography. AIM:The aim of this study was to investigate whether spleen stiffness, assessed by TE, useful tool for grading chronic liver diseases and to compare its performance in predicting the presence and size of esophageal varices in liver cirrhosis patients. METHODOLOGY:86 patients with cirrhosis and 80 controls underwent transient elastography of liver and spleen for the assessment of liver stiffness (LSM) and spleen stiffness (SSM) . Upper GI endoscopy done in all Cirrhotic patients. RESULTS: Spleen stiffness showed higher values in liver cirrhosis patients as compared with controls: 58.2 kpa vs14.8 kpa (P < 0.0001) and also found to be significantly higher in cirrhotic patients compared with varices and those without varices (69.01 vs 42.05 kpa, P < 0.0001). Liver stiffness was also found to be higher in cirrhotic patients with varices when compared to patients without varices (38.5vs 21.2 kpa). Using both liver and spleen stiffness measurement we can predicted the presence of esophageal varices correctly. CONCLUSION: Spleen stiffness can be assessed using transient elastography, higher value correlated well with liver cirrhosis and presence of esophageal varices although it couldn’t correlate with grade of Esophageal Varix. Combined assessment of spleen and liver stiffness had better prediction of presence of Esophageal Varix.


Author(s):  
Naglaa El-Toukhy Ramadan El-Toukhy ◽  
Sharaf Elsayed Ali Hassanien ◽  
Ramy A. Metwaly ◽  
Medhat A. Khalil ◽  
Badawy A. Abdulaziz

Background and Study Aims: Portal hypertension is one of the most important complications of liver cirrhosis. The prevalence of varices among cirrhotic patients is variable. Therefore, endoscopic screening of all patients with liver cirrhosis would result in a large number of unnecessary additional burdens to endoscopic units. Our aim was to assess the diagnostic accuracy of spleen stiffness measured by transient elastography (Fibroscan) for prediction of the presence of varices in patients with hepatitis C related cirrhosis. Patients and Methods: The study was carried out on 100 patients with HCV-induced cirrhosis and were divided into 2 groups according to presence or absence of varices by Esophago-gastro-duodenoscopy: Group I: patients with HCV-induced cirrhosis with varices; Group II: patients with HCV-induced cirrhosis without varices. Clinical and laboratory parameters, andominal ultrasonography, Upper gastrointestinal endoscopy and transient elastography to assess the liver and spleen stiffness were carried out to all studied persons. Results: Spleen stiffness had significant diagnostic value to differentiate between cirrhotic patients with varices and cirrhotic patients without varices , it had significant diagnostic value in presence of esophageal varices at cut-off (≥46.4 K Pascal) the sensitivity for detection of esophageal varices was 93%, specificity 100%, positive predictive value (PPV) was 80%, negative predictive value (NPV) was 100%; accuracy was 95% and area under the curve was 0.98 denoting that spleen stiffness is a good predictor of esophageal varices. Conclusion: Spleen stiffness was considered as an excellent predictor of esophageal varices and better than liver stiffness in prediction of esophageal varices presence and had significant diagnostic value to differentiate between the patients with varices and patients without varices at cut off (≥46.4 K Pascal) and it may have a role in variceal grading.


Author(s):  
Rizqi Arini Siregar ◽  
Leonardo Basa Dairi ◽  
Gontar Alamsyah Siregar

Background<br />Rupture and bleeding from esophageal varices are major complications of portal hypertension and associated with a high mortality rate. Non-invasive serum markers of liver fibrosis could be used as predictors of esophageal varices in cirrhotic patients. The objective of this study was to assess the performance of Forns index as a noninvasive predictor in diagnosing esophageal varices.<br /><br />Methods<br />A cross-sectional study was done in 51 cirrhotic patients who were admitted to Adam Malik hospital, Medan. Demographic and clinical data were recorded and laboratory tests were performed, so that Forns index could be calculated. The difference between Forns index and size of esophageal varices as determined by endoscopy was tested by independent-t and Mann-Whitney analysis. The diagnostic performance was assessed using sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, likelihood ratios and areas under the receiver operating characteristic curves (AUROC). <br /><br />Results<br />Of the 51 patients with esophageal varices included in this study, the size of esophageal varices comprised F2 (37.3%), F3 (33.3), and F1 (29.4%). Most patients were of Child-Plug C type (52.6%). There was a significant difference between Forns index and grade of esophageal varices. The AUROC for Forns index was 0.717 (95% CI: 0.561 - 0.872) and the cut-off &gt;7.92 was highly predictive to diagnose large esophageal varices with a sensitivity of 63.9%, specificity of 73.3%, PPV of 85.2%, NPV of 45.8% and accuracy of 71.7%.<br /><br />Conclusion<br />Forns index was significantly increased in large esophageal varices. Forns index is a good noninvasive predictor of esophageal varices in cirrhotic patients.


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 737
Author(s):  
Renata Fofiu ◽  
Felix Bende ◽  
Alina Popescu ◽  
Roxana Șirli ◽  
Bogdan Miuţescu ◽  
...  

The present study evaluates the performance of Baveno VI criteria, using liver stiffness (LS) assessed with a 2D-SWE elastography technique, for predicting high-risk varices (HRV) in patients with compensated advanced chronic liver disease (cACLD). A secondary aim was to determine whether the use of spleen stiffness measurements (SSMs), as additional criteria, increases the performance of the 2D-SWE Baveno VI criteria. Data were collected from 208 subjects with cACLD, who underwent abdominal ultrasound, liver and spleen stiffness measurements, and upper digestive endoscopy. HRV were defined as grade 1 esophageal varices (EV) with red wale marks, grade 2/3 EV, and gastric varices. A total of 35.6% (74/208) of the included subjects had HRV. The optimal LS cut-off value for predicting HRV was 12 kPa (AUROC-0.80). Using both LS cut-off value < 12 kPa and a platelet cut-off value > 150 × 109 cells/L as criteria to exclude HRV, 52/208 (25%) subjects were selected, 88.5% (46/52) were without EV, 9.6% (5/52) had grade 1 EV, and 1.9% (1/52) had HRV. Thus 98% of the subjects were correctly classified as having or not having HRV and 25% of the surveillance endoscopies could have been avoided. Using SS < 13.2 kPa and a platelet cut-off value > 150 × 109 cells/L as additional criteria for the patients that were outside the initial ones, 32.7% of the surveillance endoscopies could have been avoided.


Author(s):  
Anders Batman Mjelle ◽  
Anesa Mulabecirovic ◽  
Roald Flesland Havre ◽  
Edda Jonina Olafsdottir ◽  
Odd Helge Gilja ◽  
...  

Abstract Purpose Liver elastography is increasingly being applied in screening for and follow-up of pediatric liver disease, and has been shown to correlate well with fibrosis staging through liver biopsy. Because time is of the essence when examining children, we wanted to evaluate if a reliable result can be achieved with fewer acquisitions. Materials and Methods 243 healthy children aged 4–17 years were examined after three hours of fasting. Participants were divided into four age groups: 4–7 years; 8–11 years; 12–14 years and 15–17 years. Both two-dimensional shear wave elastography (2D-SWE; GE Logiq E9) and point shear wave elastography (pSWE; Samsung RS80A with Prestige) were performed in all participants, while transient elastography (TE, Fibroscan) was performed in a subset of 87 children aged 8–17 years. Median liver stiffness measurement (LSM) values of 3, 4, 5, 6, 7, and 8 acquisitions were compared with the median value of 10 acquisitions (reference standard). Comparison was performed for all participants together as well as within every specific age group. We investigated both the intraclass correlation coefficient (ICC) with absolute agreement and all outliers more than 10 %, 20 % or ≥ 0.5 or 1.0 kPa from the median of 10 acquisitions. Results For all three systems there was no significant difference between three and ten acquisitions, with ICCs ≥ 0.97. All systems needed 4 acquisitions to achieve no LSM deviating ≥ 1.0 kPa of a median of ten. To achieve no LSM deviating ≥ 20 % of a median of ten acquisitions, pSWE and TE needed 4 acquisitions, while 2D-SWE required 6 acquisitions. Conclusion Our results contradict recommendations of 10 acquisitions for pSWE and TE and only 3 for 2D-SWE.


SLEEP ◽  
2020 ◽  
Vol 43 (Supplement_1) ◽  
pp. A225-A225
Author(s):  
J Xue ◽  
R Zhao ◽  
J Li ◽  
L Zhao ◽  
B Zhou ◽  
...  

Abstract Introduction To evaluate the utility of the ring pulse oximeter for screening of OSA in adults. Methods 87 adults were monitored by a ring pulse oximeter and PSG simultaneously during a nocturnal in-lab sleep testing. 3% oxygen desaturation index (ODI3); Mean oxygen saturation(MSpO2), Saturation impair time below 90% (SIT90) derived from an automated algorithm of the ring pulse oximeter. Meanwhile, the parameters of PSG were scored manually according to the AASM Manual. Correlation and receiver operator characteristic curve analysis were used to measure the accuracy of ring pulse oximeter and its diagnostic value for moderate to severe OSA (AHI≥15). Results Among the 87 participants, 18 cases were AHI&lt;5, 17 cases were diagnosed with mild OSA (AHI:5-14.9), 25 cases were diagnosed with moderate OSA (AHI:15-29.9) and 27 cases were diagnosed with severe OSA (AHI≥30). There was no significant difference between PSG and ring pulse oximeter in regard to ODI3 (23.4±23.5 vs 24.7 ± 21.7), and SIT90 (1.54%, range 0.14%-8.99% vs. 3.20%, range 0.60%, 12.30%) (P&gt;0.05], Further analysis indicated that two parameters from the oximeter correlated well with that derived from PSG (r=0.889, 0.567, respectively, both p&lt;0.05). Although MSpO2 correlated significantly (r=0.448, P&lt;0.05), the difference was remarkable [95.9%, range 94.0% to 97.0% vs. 94.5%, range 93.3% to 95.7%, p&lt;0.05]. Bland-Altman plots showed that the agreement of these three parameters was within the clinical acceptance range. The ROC curve showed that the sensitivity and specificity of the ring pulse oximeter when the oximeter derived ODI3 ≥12.5 in the diagnosis of moderate to severe OSA were 82.7% and 74.3%, respectively. Conclusion The pilot study indicated that ring pulse oximeter can detect oxygen desaturation events accurately, therefore to be used as a screening tool for moderate to severe OSA. Support The study was supported by the National Natural Science Foundation of China (No. 81420108002 and NO. 81570083).


2015 ◽  
Vol 23 (3) ◽  
pp. 256-274 ◽  
Author(s):  
Monika Kansal ◽  
Mahesh Joshi

Purpose – The purpose of this paper is to investigate the extent of corporate disclosure on human resources (HR) in the annual reports of top performing Indian companies. Design/methodology/approach – The paper explores the extent to which top 82 companies from India present information about HR in their annual reports. This study examines the annual reports of each of the top Indian firms listed on the Bombay stock exchange, using the “content analysis” method. Statistical tests have been performed to analyse the difference between the HR disclosure score across public and private sectors and disclosure variations among various industrial sectors. Findings – In-house training programmes has been noticed to be the favourite item of disclosure followed by safety awards/certifications and statements regarding cordial relations with the employees/unions. A majority of the Indian firms have ignored significant HR issues such as employee welfare fund, maternity/paternity leaves, holiday benefits, employee loans and adopting old age homes, etc. Overall, the study reflects low HR related disclosures. No statistically significant difference has been found between the mean HR disclosure from one industry to another and disclosure practices of the private and the public sector companies. Practical implications – The disclosure pattern of the Indian companies suggests that they only a few companies are concerned about employees’ welfare than the rest. This may motivate a change of the disclosure policy of the rest of the firms who may follow the reporting pattern of the most disclosing ones. Originality/value – This is first study on the disclosure of HR by the Indian corporate sector in the CSR domain with a disclosure analysis for a period of nine years . This research provides new directions for the literature in this area and may promote comparative studies on HR-based studies from different perspectives.


Sign in / Sign up

Export Citation Format

Share Document