scholarly journals A deep learning approach to estimate stress distribution: a fast and accurate surrogate of finite-element analysis

2018 ◽  
Vol 15 (138) ◽  
pp. 20170844 ◽  
Author(s):  
Liang Liang ◽  
Minliang Liu ◽  
Caitlin Martin ◽  
Wei Sun

Structural finite-element analysis (FEA) has been widely used to study the biomechanics of human tissues and organs, as well as tissue–medical device interactions, and treatment strategies. However, patient-specific FEA models usually require complex procedures to set up and long computing times to obtain final simulation results, preventing prompt feedback to clinicians in time-sensitive clinical applications. In this study, by using machine learning techniques, we developed a deep learning (DL) model to directly estimate the stress distributions of the aorta. The DL model was designed and trained to take the input of FEA and directly output the aortic wall stress distributions, bypassing the FEA calculation process. The trained DL model is capable of predicting the stress distributions with average errors of 0.492% and 0.891% in the Von Mises stress distribution and peak Von Mises stress, respectively. This study marks, to our knowledge, the first study that demonstrates the feasibility and great potential of using the DL technique as a fast and accurate surrogate of FEA for stress analysis.

Author(s):  
Z Yi ◽  
WZ Fu ◽  
MZ Li

In order to obtain a higher pressure capacity for the high-pressure die with a larger sample cavity, two types of two-layer split dies with a round cylinder and a quadrate cylinder were designed based on the conventional belt-type die. Finite element analysis was performed to investigate the stress distributions and pressure capacities of the high-pressure dies using a derived Mohr–Coulomb criterion and the von Mises criterion for the cylinder and supporting rings, respectively. As predicted by the finite element analysis results, in the two-layer split dies with a round cylinder, the stress state of the cylinder can be only slightly improved; and the von Mises stress of the first layer supporting ring can be hardly decreased. However, in the two-layer split dies with a quadrate cylinder and sample cavity, the stress state of the cylinder can be remarkably improved. Simultaneously, the von Mises stress of the supporting rings, especially for the first-layer supporting ring, can be also effectively decreased. The pressure capacities of the two-layer split dies with a round cylinder and a quadrate cylinder are 16.5% and 63.9% higher with respect to the conventional belt-type die.


Nanomaterials ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 1708 ◽  
Author(s):  
Maciej Zarow ◽  
Mirco Vadini ◽  
Agnieszka Chojnacka-Brozek ◽  
Katarzyna Szczeklik ◽  
Grzegorz Milewski ◽  
...  

By means of a finite element method (FEM), the present study evaluated the effect of fiber post (FP) placement on the stress distribution occurring in endodontically treated upper first premolars (UFPs) with mesial–occlusal–distal (MOD) nanohybrid composite restorations under subcritical static load. FEM models were created to simulate four different clinical situations involving endodontically treated UFPs with MOD cavities restored with one of the following: composite resin; composite and one FP in the palatal root; composite and one FP in the buccal root; or composite and two FPs. As control, the model of an intact UFP was included. A simulated load of 150 N was applied. Stress distribution was observed on each model surface, on the mid buccal–palatal plane, and on two horizontal planes (at cervical and root-furcation levels); the maximum Von Mises stress values were calculated. All analyses were replicated three times, using the mechanical parameters from three different nanohybrid resin composite restorative materials. In the presence of FPs, the maximum stress values recorded on dentin (in cervical and root-furcation areas) appeared slightly reduced, compared to the endodontically treated tooth restored with no post; in the same areas, the overall Von Mises maps revealed more favorable stress distributions. FPs in maxillary premolars with MOD cavities can lead to a positive redistribution of potentially dangerous stress concentrations away from the cervical and the root-furcation dentin.


Paleobiology ◽  
2019 ◽  
Vol 45 (1) ◽  
pp. 182-200 ◽  
Author(s):  
François Clarac ◽  
Florent Goussard ◽  
Vivian de Buffrénil ◽  
Vittorio Sansalone

AbstractThis paper aims at assessing the influence of the bone ornamentation and, specifically, the associated loss of bone mass on the mechanical response of the crocodylomorph osteoderms. To this end, we have performed three-dimensional (3D) modeling and a finite element analysis on a sample that includes both extant dry bones and well-preserved fossils tracing back to the Late Triassic. We simulated an external attack under various angles on the apical surface of each osteoderm and further repeated the simulation on an equivalent set of smoothed 3D-modeled osteoderms. The comparative results indicated that the presence of an apical sculpture has no significant influence on the von Mises stress distribution in the osteoderm volume, although it produces a slight increase in its numerical score. Moreover, performing parametric analyses, we showed that the Young's modulus of the osteoderm, which may vary depending on the bone porosity, the collagen fiber orientation, or the calcification density, has no impact on the von Mises stress distribution inside the osteoderm volume. As the crocodylomorph bone ornamentation is continuously remodeled by pit resorption and secondary bone deposition, we assume that the apical sculpture may be the outcome of a trade-off between the bone mechanical resistance and the involvement in physiological functions. These physiological functions are indeed based on the setup of a bone superficial vessel network and/or the recurrent release of mineral elements into the plasma: heat transfers during basking and respiratory acidosis buffering during prolonged apnea in neosuchians and teleosaurids; compensatory homeostasis in response to general calcium deficiencies. On a general morphological basis, the osteoderm geometric variability within our sample leads us to assess that the global osteoderm geometry (whether square or rectangular) does not influence the von Mises stress, whereas the presence of a dorsal keel would somewhat reduce the stress along the vertical axis.


2020 ◽  
Author(s):  
Kazuhiro Hasegawa ◽  
Tamon Kabata ◽  
Yoshitomo Kajino ◽  
Daisuke Inoue ◽  
Jiro Sakamoto ◽  
...  

Abstract Background Finite element analysis (FEA) has been previously applied for the biomechanical analysis of acetabular dysplasia and osteotomy. However, until now, there have been little reports on the use of FEA to evaluate the effects of pelvic tilt on stress distribution in the acetabulum. Methods We used the Mechanical Finder Ver. 7.0 (RCCM, Inc., Japan) to construct finite element models based on 3D-CT data of patients, and designed dysplasia, borderline, and normal pelvic models. For analysis, body weight was placed on the sacrum and the load of the flexor muscles of the hip joint was placed on the ilium. The pelvic tilt was based on the anterior pelvic plane, and the pelvic tilt angles were -20°, 0°, and 20°. The load of the flexor muscle of the hip joint was calculated using the moment arm equation.Results All three models showed the highest values of von Mises stress in the -20° pelvic tilt angle, and the lowest in the 20° angle. Stress distribution concentrated in the load-bearing area. The maximum values of von Mises stress in the borderline at pelvic tilt angles of -20° was 3.5Mpa, and in the dysplasia at pelvic tilt angles of 0° was 3.1Mpa. Conclusions The pelvic tilt angle of -20° of the borderline model showed equal maximum values of von Mises stress than the dysplasia model of pelvic tilt angle of 0°, indicating that pelvic retroversion of -20° in borderline is a risk factor for osteoarthritis of the hip joints, similar to dysplasia.


Author(s):  
Vinod Bandela ◽  
Ram Basany ◽  
Anil Kumar Nagarajappa ◽  
Sakeenabi Basha ◽  
Saraswathi Kanaparthi ◽  
...  

Purpose: To analyze the stress distribution and the direction of force in external hexagonal implant with crown in three different angulations. Materials and Methods: A total of 60 samples of geometric models were used to analyze von Mises stress and direction of force with 0-, 5-, and 10-degree lingual tilt. Von Mises stress and force distribution were evaluated at nodes of hard bone, and finite element analysis was performed using ANSYS 12.1 software. For calculating stress distribution and force, we categorized and labeled the groups as Implant A1, Implant A2, and Implant A3, and Implant B1, Implant B2, and Implant B3 with 0-, 5-, and 10-degree lingual inclinations, respectively. Inter- and intra-group comparisons were performed using ANOVA test. A p-value of ≤0.05 was considered statistically significant. Results: In all the three models, overall maximum stress was found in implant model A3 on the implant surface (86.61), and minimum was found on model A1 in hard bone (26.21). In all the three models, the direction of force along three planes was maximum in DX (0.01025) and minimum along DZ (0.002) direction with model B1. Conclusion: Maximum von Mises stress and the direction of force in axial direction was found at the maximum with the implant of 10 degrees angulation. Thus, it was evident that tilting of an implant influences the stress concentration and force in external hex implants.


2020 ◽  
Vol 54 (2) ◽  
pp. 106-114
Author(s):  
Udita Thakkar ◽  
Neeraj S. Patil ◽  
Ajay P. Thakkar ◽  
Shrikant S. Chitko ◽  
Pratik Jaltare

Introduction: Correction of deep bite is one of the major challenges of orthodontic treatment. Mini-implants provide stable intra-oral anchorage and facilitate the maxillary incisors to be intruded without the usual side. The purpose of this finite element study was to evaluate the stress distribution around the mini-implant during maxillary anterior intrusion under different conditions of different angulations and different positions of implant. Material and Methods: Finite element analysis was carried out. Stress under the following 4 conditions was analyzed: (a) single central implant placed at 90°, (b) single central implant placed at 120°, (c) bilaterally placed implant at 90°, and (d) bilaterally placed implant at 120°. Results: The displacement seen with 90° angulation in the single implant case is less compared with the 120° angulation case for all the 6 maxillary anterior teeth. Also, in the bilateral implant case, the Von Mises stress is less when the 90° angulation case is compared to 120° angulation case. But in bilaterally placed implant, the stress gets distributed evenly in the anterior region. The stress in 90° angulation cases seems to be concentrated at the center. Conclusion: Stresses measured on the teeth are less and distributed more evenly when the point of force application is bilateral. It was also observed that the stress increases with increase in the angulation of the implant. As the contact between the implant and the bone increases, the stability increases. Hence, the implant should be obliquely inserted into the bone. Concentrated stresses are not favorable as they can increase the risk of bone and root resorption.


2011 ◽  
Vol 199-200 ◽  
pp. 1595-1599
Author(s):  
Dian Xin Li ◽  
Hong Lin Zhao ◽  
Shi Min Zhang ◽  
Chang Run Wu ◽  
Xian Long Liu ◽  
...  

Based on finite element analysis software ANSYS, the deformation and force condition of the rubber sealing o-ring pre and post with back-up ring under different oil pressure conditions was analyzed. The von mises stress distribution of the o-ring and the change of contact pressure between o-ring and sealing interface pre and post with back-up ring under different oil pressure conditions were discussed. The results show that, the maximum von mises stress of the o-ring is smaller and the maximum von mises stress of the sealing system concentrates on the left top and the right bottom of the back-up ring after using it; the o-ring will not be extruded into the gap of the groove because of the existence of back-up ring which prevents gap-bite and prolongs service life of the o-ring; the contact pressure between o-ring and sealing interface increased, thus the sealing reliability of the system increased.


2018 ◽  
Vol 6 (7) ◽  
pp. 272-277
Author(s):  
Maj Pankaj Awasthi ◽  
Lt Col Sonali Sharma ◽  
Maj Summerdeep Kaur

Aim: To study the stress distribution in Class 2 Inlay of various materials on Mandibular Molar. Background: Inlays are fabricated using different materials like gold, porcelain or a cast metal alloy. Difference in the modulus of elasticity of the material and tooth structure would lead to generation of stresses leading to failure of the restoration or loss of tooth structure. Finite Element Analysis (FEA) is a mathematical tool for stress analysis in a structure. Von Mises stress being the combination of normal and shear stresses which occur in all directions. This stress has to be given diligent importance while considering the type and material of restoration to achieve long-term success. Methodology: In our study, stress analysis was performed on the mandibular first molar using a stress analysis software (ANSYS). A computer model of mandibular first molar was generated along with generation of an inlay volume using a FEA software preprocessor. The models with the class 2 inlays of different materials were subjected to 350N and 800N load simulating normal masticatory force and bruxism respectively. Maximum and minimum stresses were calculated for each model separately. Results: Von Mises stress distribution for different materials for normal masticatory forces and bruxism were studied and evaluated. Conclusion: The study revealed the maximum and minimum stresses imposed over the tooth and the restoration and provides insight into the areas which are more prone to fracture under the occlusal load.


Author(s):  
Amirhesam Amerinatanzi ◽  
Narges Shayesteh Moghaddam ◽  
Ahmadreza Jahadakbar ◽  
David Dean ◽  
Mohammad Elahinia

The most common method for mandibular reconstructive surgery is the use of a Ti-6Al-4V fixation device and a fibular double barrel graft. This highly stiff fixation hardware (E = 112 GPa) often shields the bone graft (E = 20 GPa) from carrying the load, which may result in bone resorption. Highly stiff Ti-6Al-4V fixation hardware is also likely to concentrate stress in the fixation plate or at screw threads, possibly leading to hardware cracking or screw pull-out. As a solution for that, we have proposed and studied the effect of using a low stiffness, porous NiTi fixation device [1–4]. Although the stress in the fixation device is increased, using such low stiffness fixation hardware, is preferable to have an even higher stress on the graft in order to minimize the risk of resorption or hardware failure. We assume that preloading screws allows them to better engage the fixation hardware with the plate and the surrounding bone and causes an increased von Mises stress. The fixation device can be patient-specific and additively manufactured, such that the shape would match the outer surface of the cortical bone. In this study, we modeled a healthy cadaver mandible via CT-derived 3D surface data. The mandible was virtually resected in the molar region (M1−3). The model simulated the result of reconstructive surgery under the highest chewing loading regime (i.e., 526 N on first right molar tooth [5, 6]) where reconstruction was done with either Ti-6Al-4V fixation hardware or patient specific, stiffness-matched, porous NiTi fixation hardware. The calibration of the material properties for this simulation was done using experimentally obtained data (DSC and compression tests) of Ni-rich NiTi bulk samples. The analyzed term in the finite element analysis was stress distribution in the cortical and cancellous bone. Porous NiTi fixation devices were also produced using Selective Laser Melting (SLM) using the geometry of the aforementioned cadaver mandible. In this paper we have studied the effect of additional torque or preload on the performance of the fixation plates. The finite element analysis demonstrated that applying a preload to the screws increased the stress on the bone. Under similar levels of applied preload, the porous NiTi fixation device showed an increased level of von Mises stress in the bone, particularly in the graft. Additionally, the analysis indicated the higher level of stress on the bone surrounding the screws for the case of using NiTi, which could contribute to increasing screw stability. The fabricated patient-specific fixation hardware not only matched the shape of cortical bone but also contained the level of porosity that defines the appropriate modulus of elasticity.


Sign in / Sign up

Export Citation Format

Share Document