scholarly journals Rapid 3D enhanced resolution microscopy reveals the dynamics of cortical dendritic spinules

2019 ◽  
Author(s):  
CR Zaccard ◽  
K Myczek ◽  
MD Martin-de-Saavedra ◽  
P Penzes

SummaryDendritic spinules are thin, membranous protrusions formed by neuronal dendritic spines that are not adequately resolved by diffraction-limited light microscopy. Hence, our understanding of spinules is inferred predominantly from fixed-tissue electron microscopy (EM). Super-resolution modalities have enabled live-cell nanoscopic imaging, but their utility for fast, time-lapse, volumetric imaging has been restricted. Herein, we utilized rapid structured illumination microscopy (SIM) and ‘enhanced resolution’ confocal microscopy to study spatiotemporal spinule dynamics in live cultured cortical pyramidal neurons. Spinules on mushroom spines typically recurred at the same topographical locations and most were short-lived, originating near simple post-synaptic densities (PSDs), while a subset was long-lived and elongated, emerging from complex PSDs. Ca2+ puncta within spinules synchronized with spine head transients and Ca2+ depletion drastically decreased spinule number. Moreover, we uncovered evidence of differential Ca2+-mediated regulation of short-lived and long-lived spinules. Thus, we identified unique spinule classes divergent in lifespan, dynamics, morphology, relationship to the PSD, and regulation. These data suggest distinct synaptic functions of spinule classes, informing future studies, while demonstrating a new application for enhanced resolution microscopy.

2016 ◽  
Vol 09 (03) ◽  
pp. 1630002 ◽  
Author(s):  
Qiang Yang ◽  
Liangcai Cao ◽  
Hua Zhang ◽  
Hao Zhang ◽  
Guofan Jin

The image reconstruction process in super-resolution structured illumination microscopy (SIM) is investigated. The structured pattern is generated by the interference of two Gaussian beams to encode undetectable spectra into detectable region of microscope. After parameters estimation of the structured pattern, the encoded spectra are computationally decoded and recombined in Fourier domain to equivalently increase the cut-off frequency of microscope, resulting in the extension of detectable spectra and a reconstructed image with about two-fold enhanced resolution. Three different methods to estimate the initial phase of structured pattern are compared, verifying the auto-correlation algorithm affords the fast, most precise and robust measurement. The artifacts sources and detailed reconstruction flowchart for both linear and nonlinear SIM are also presented.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Liliana Barbieri ◽  
Huw Colin-York ◽  
Kseniya Korobchevskaya ◽  
Di Li ◽  
Deanna L. Wolfson ◽  
...  

AbstractQuantifying small, rapidly evolving forces generated by cells is a major challenge for the understanding of biomechanics and mechanobiology in health and disease. Traction force microscopy remains one of the most broadly applied force probing technologies but typically restricts itself to slow events over seconds and micron-scale displacements. Here, we improve >2-fold spatially and >10-fold temporally the resolution of planar cellular force probing compared to its related conventional modalities by combining fast two-dimensional total internal reflection fluorescence super-resolution structured illumination microscopy and traction force microscopy. This live-cell 2D TIRF-SIM-TFM methodology offers a combination of spatio-temporal resolution enhancement relevant to forces on the nano- and sub-second scales, opening up new aspects of mechanobiology to analysis.


Nanophotonics ◽  
2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Ruslan Röhrich ◽  
A. Femius Koenderink

AbstractStructured illumination microscopy (SIM) is a well-established fluorescence imaging technique, which can increase spatial resolution by up to a factor of two. This article reports on a new way to extend the capabilities of structured illumination microscopy, by combining ideas from the fields of illumination engineering and nanophotonics. In this technique, plasmonic arrays of hexagonal symmetry are illuminated by two obliquely incident beams originating from a single laser. The resulting interference between the light grating and plasmonic grating creates a wide range of spatial frequencies above the microscope passband, while still preserving the spatial frequencies of regular SIM. To systematically investigate this technique and to contrast it with regular SIM and localized plasmon SIM, we implement a rigorous simulation procedure, which simulates the near-field illumination of the plasmonic grating and uses it in the subsequent forward imaging model. The inverse problem, of obtaining a super-resolution (SR) image from multiple low-resolution images, is solved using a numerical reconstruction algorithm while the obtained resolution is quantitatively assessed. The results point at the possibility of resolution enhancements beyond regular SIM, which rapidly vanishes with the height above the grating. In an initial experimental realization, the existence of the expected spatial frequencies is shown and the performance of compatible reconstruction approaches is compared. Finally, we discuss the obstacles of experimental implementations that would need to be overcome for artifact-free SR imaging.


2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Gang Wen ◽  
Simin Li ◽  
Linbo Wang ◽  
Xiaohu Chen ◽  
Zhenglong Sun ◽  
...  

AbstractStructured illumination microscopy (SIM) has become a widely used tool for insight into biomedical challenges due to its rapid, long-term, and super-resolution (SR) imaging. However, artifacts that often appear in SIM images have long brought into question its fidelity, and might cause misinterpretation of biological structures. We present HiFi-SIM, a high-fidelity SIM reconstruction algorithm, by engineering the effective point spread function (PSF) into an ideal form. HiFi-SIM can effectively reduce commonly seen artifacts without loss of fine structures and improve the axial sectioning for samples with strong background. In particular, HiFi-SIM is not sensitive to the commonly used PSF and reconstruction parameters; hence, it lowers the requirements for dedicated PSF calibration and complicated parameter adjustment, thus promoting SIM as a daily imaging tool.


Author(s):  
Yizhao Guan ◽  
Hiromasa Kume ◽  
Shotaro Kadoya ◽  
Masaki Michihata ◽  
Satoru Takahashi

Abstract Microstructures are widely used in the manufacture of functional surfaces. An optical-based super-resolution, non-invasive method is preferred for the inspection of surfaces with massive microstructures. The Structured Illumination Microscopy (SIM) uses standing-wave illumination to reach optical super-resolution. Recently, coherent SIM is being studied. It can obtain not only the super-resolved intensity distribution but also the phase and amplitude distribution of the sample surface beyond the diffraction limit. By analysis of the phase-depth dependency, the depth measurement for microgroove structures with coherent SIM is expected. FDTD analysis is applied for observing the near-field response of microgroove under the standing-wave illumination. The near-field phase shows depth dependency in this analysis. Moreover, the effects from microgroove width, the incident angle, and the relative position between the standing-wave peak and center of the microgroove are investigated. It is found the near-field phase change can measure depth until 200 nm (aspect ratio 1) with an error of up to 20.4 nm in the case that the microgroove width is smaller than half of the wavelength.


2020 ◽  
Vol 52 (1) ◽  
pp. 369-393
Author(s):  
Minami Yoda

Quantifying submillimeter flows using optical diagnostic techniques is often limited by a lack of spatial resolution and optical access. This review discusses two super-resolution imaging techniques, structured illumination microscopy and total internal reflection fluorescence or microscopy, which can visualize bulk and interfacial flows, respectively, at spatial resolutions below the classic diffraction limits. First, we discuss the theory and applications of structured illumination for optical sectioning, i.e., imaging a thin slice of a flow illuminated over its entire volume. Structured illumination can be used to visualize the interior of multiphase flows such as sprays by greatly reducing secondary scattering. Second, the theory underlying evanescent waves is introduced, followed by a review of how total internal reflection microscopy has been used to visualize interfacial flows over the last 15 years. Both techniques, which are starting to be used in fluid mechanics, could significantly improve quantitative imaging of microscale and macroscale flows.


2019 ◽  
Vol 10 (1) ◽  
Author(s):  
Karl Zhanghao ◽  
Xingye Chen ◽  
Wenhui Liu ◽  
Meiqi Li ◽  
Yiqiong Liu ◽  
...  

Abstract Fluorescence polarization microscopy images both the intensity and orientation of fluorescent dipoles and plays a vital role in studying molecular structures and dynamics of bio-complexes. However, current techniques remain difficult to resolve the dipole assemblies on subcellular structures and their dynamics in living cells at super-resolution level. Here we report polarized structured illumination microscopy (pSIM), which achieves super-resolution imaging of dipoles by interpreting the dipoles in spatio-angular hyperspace. We demonstrate the application of pSIM on a series of biological filamentous systems, such as cytoskeleton networks and λ-DNA, and report the dynamics of short actin sliding across a myosin-coated surface. Further, pSIM reveals the side-by-side organization of the actin ring structures in the membrane-associated periodic skeleton of hippocampal neurons and images the dipole dynamics of green fluorescent protein-labeled microtubules in live U2OS cells. pSIM applies directly to a large variety of commercial and home-built SIM systems with various imaging modality.


Sign in / Sign up

Export Citation Format

Share Document