Dependence of small-angle neutron scattering contrast on the difference in thermal expansions of phases in two-phase alloys

2009 ◽  
Vol 42 (6) ◽  
pp. 981-989 ◽  
Author(s):  
Pavel Strunz ◽  
Ralph Gilles ◽  
Debashis Mukherji ◽  
Michael Hofmann ◽  
Dominique del Genovese ◽  
...  

Theoretical expressions describing small-angle neutron scattering (SANS) contrast dependence on temperature in the region where no phase-composition changes occur were derived for two-phase Ni superalloys. The theory is based on the difference in thermal expansion of the two primary phases, γ and γ′. The simulations show that the scattering contrast temperature evolution is significant enough to be considered inin situSANS experiments with superalloys at elevated temperatures. The simulations performed show that the magnitude of the scattering contrast at room temperature is firmly connected with the particular shape of the scattering contrast temperature dependence. This fact can be used for determination of the scattering contrast without a knowledge of the compositions of the individual phases. The theoretical expressions derived for scattering contrast were proven experimentally on an Ni–Fe-base alloy, DT706. The evolution of lattice parameters of both the matrix and the precipitate phases was obtained from anin situwide-angle neutron diffraction experiment. The theoretical scattering contrast dependence was then successfully fitted to the measured SANS integral intensity.

Author(s):  
G. Kostorz

AbstractThe basic principles of small-angle neutron scattering and the two-phase model, frequently used for the interpretation of scattering data, are presented. Some studies on phase separation in alloy single crystals serve to illustrate the possibilities of the method. Small-angle neutron scattering of Ni-rich Ni—Ti studied during ageing at elevated temperatures indicates a complex sequence of phases during decomposition, involving two stages of metastable coherent precipitation preceding the formation of the stable hexagonal phase.


2004 ◽  
Vol 37 (3) ◽  
pp. 438-444 ◽  
Author(s):  
Florian Nettesheim ◽  
Ulf Olsson ◽  
Peter Lindner ◽  
Walter Richtering

A method of correcting the asymmetry in the scattering of the tangential beam configuration in a rheo-small-angle neutron scattering experiment is proposed. The asymmetry of the scattering in the tangential beam configuration can be attributed to the difference in pathlength for neutrons that are scattered toward compared with those which are scattered away from the axis of rotation of the shear cell. The pathlength problem is solved and a final expression for the two-dimensional scattering intensity is given. The results from these calculations are compared with experimental data, which offer a different option to correct this asymmetry, namely by just measuring the scattering of H2O/D2O mixtures with absolute scattering cross sections identical to those of the respective samples. However, the situation for anisotropic media is more complex and the correction procedure described here is less effective.


Carbon ◽  
2013 ◽  
Vol 57 ◽  
pp. 460-469 ◽  
Author(s):  
Félix Balima ◽  
Vittoria Pischedda ◽  
Sylvie Le Floch ◽  
Annie Brûlet ◽  
Peter Lindner ◽  
...  

Langmuir ◽  
2019 ◽  
Vol 35 (10) ◽  
pp. 3822-3831 ◽  
Author(s):  
Ignacio Martín-Fabiani ◽  
David K. Makepeace ◽  
Philip G. Richardson ◽  
Jennifer Lesage de la Haye ◽  
Diego Alba Venero ◽  
...  

2013 ◽  
Vol 46 (5) ◽  
pp. 1361-1371 ◽  
Author(s):  
B. Hammouda ◽  
D. F. R. Mildner ◽  
A. Brûlet ◽  
S. Desert

Neutron focusing leads to significant gains in flux-on-sample in small-angle neutron scattering and very small angle neutron scattering instruments. Understanding the out-of-focus condition is necessary for less than optimal conditions such as for short instruments and low neutron wavelengths. Neutron focusing is investigated using a three-pronged approach. The three methods are analytical calculations, resolution measurements and computer simulations. A source aperture containing a single small-size hole and a sample aperture containing multiple holes are used to produce multiple spots on the high-resolution neutron detector. Lens focusing elongates off-axis spots in the radial direction. The standard deviation for the size of each spot is estimated using these three approaches. Varying parameters include the neutron wavelength, the number of focusing lenses and the location of holes on the sample aperture. Enough agreement for the standard deviation of the individual neutron beams was found between the calculations and the measurements to give confidence in this approach. Good agreement was found between the standard deviations obtained from calculations and simulations as well. Excellent agreement was found for the mean location of these individual spots.


2011 ◽  
Vol 1334 ◽  
Author(s):  
Dipendu Saha ◽  
Lilin He ◽  
Cristian I. Contescu ◽  
Nidia C. Gallego ◽  
Yuri B. Melnichenko

ABSTRACTEntrapping hydrogen molecules within the nanopores of solid adsorbents serves as a unique alternative for on-board storing of hydrogen for transportation purposes. The key advantage of the physisorption process for hydrogen storage is the higher density values achieved with the adsorbed gas, compared to that of the compressed phase, translating into higher storage capacities at lower pressures. The necessary condition for effective adsorption is the presence of narrow micropores of < 2 nm in width which provide the most suitable environment of hydrogen adsorption. Despite numerous theoretical calculations or indirect experimental estimations, there has not been a direct experimental measurement of the density of adsorbed hydrogen as a function of pressure and/or pore size. In the present study, we report on the use of in-situ small angle neutron scattering (SANS) to study the phase behavior of hydrogen confined in narrow micropores. We provide for the first time direct experimental measurements of the effect of pore size and pressure on hydrogen adsorbed on a polyfurfuryl alcohol-derived activated carbon (PFAC), at room temperature and pressures up to 207 bar. SANS studies were carried out at the General-Purpose Small-Angle Neutron Scattering spectrometer of the High Flux Isotope Reactor at Oak Ridge National Laboratory. The measurements covered the Q-range from 0.01 to 0.8 Å-1, covering the pores in the range of 9 to 34 Å of the PFAC material. Initial results suggest that the density of adsorbed hydrogen is higher than the density of bulk hydrogen gas and increases with decreasing pore size.


Sign in / Sign up

Export Citation Format

Share Document