Point-group determination by convergent-beam electron diffraction

Author(s):  
M. Tanaka ◽  
R. Saito ◽  
H. Sekii
1987 ◽  
Vol 51 (359) ◽  
pp. 33-48 ◽  
Author(s):  
P. E. Champness

AbstractIn convergent-beam electron diffraction (CBED) a highly convergent electron beam is focussed on to a small (⩽50 nm) area of the sample. Instead of the diffraction spots that are obtained in the back focal plane of the objective lens with parallel illumination in conventional selected-area electron diffraction, CBED produces discs of intensity. The point group can be determined uniquely from the symmetry within the individual discs and the overall pattern. In order to determine the point group, it is usually necessary to record a number of CBED patterns with the electron beam aligned along different zone axes, but sometimes only one, high-symmetry pattern is required. The positions of reflections in higher-order Laue zones can be used to identify the crystal system and lattice type and to detect the presence of certain glide planes. The repeat along the zone axis that is parallel to the beam can be calculated from the diameters of the Laue zones. Hence the presence ofpolymorphs can be detected. Doubly-diffracted discs in CBED often contain a ‘line of dynamic absence’, the orientation of this line with respect to the symmetry seen in the bright field disc allows the symmetry element responsible for it (glide plane or screw diad) to be identified. This allows 191 of the 230 space groups to be uniquely identified. The measurement of specimen thickness, extinction distance and cell parameters are also briefly discussed.


Author(s):  
K. Ishizuka

The technique of convergent-beam electron diffraction (CBED) has been established. However there is a distinct discrepancy concerning the CBED pattern symmetries associated with translation symmetries parallel to the incident beam direction: Buxton et al. assumed no detectable effects of translation components, while Goodman predicted no associated symmetries. In this report a procedure used by Gjønnes & Moodie1 to obtain dynamical extinction rules will be extended in order to derive the CBED pattern symmetries as well as the dynamical extinction rules.


Author(s):  
John F. Mansfield

One of the most important advancements of the transmission electron microscopy (TEM) in recent years has been the development of the analytical electron microscope (AEM). The microanalytical capabilities of AEMs are based on the three major techniques that have been refined in the last decade or so, namely, Convergent Beam Electron Diffraction (CBED), X-ray Energy Dispersive Spectroscopy (XEDS) and Electron Energy Loss Spectroscopy (EELS). Each of these techniques can yield information on the specimen under study that is not obtainable by any other means. However, it is when they are used in concert that they are most powerful. The application of CBED in materials science is not restricted to microanalysis. However, this is the area where it is most frequently employed. It is used specifically to the identification of the lattice-type, point and space group of phases present within a sample. The addition of chemical/elemental information from XEDS or EELS spectra to the diffraction data usually allows unique identification of a phase.


Author(s):  
J W Steeds

That the techniques of convergent beam electron diffraction (CBED) are now widely practised is evident, both from the way in which they feature in the sale of new transmission electron microscopes (TEMs) and from the frequency with which the results appear in the literature: new phases of high temperature superconductors is a case in point. The arrival of a new generation of TEMs operating with coherent sources at 200-300kV opens up a number of new possibilities.First, there is the possibility of quantitative work of very high accuracy. The small probe will essentially eliminate thickness or orientation averaging and this, together with efficient energy filtering by a doubly-dispersive electron energy loss spectrometer, will yield results of unsurpassed quality. The Bloch wave formulation of electron diffraction has proved itself an effective and efficient method of interpreting the data. The treatment of absorption in these calculations has recently been improved with the result that <100> HOLZ polarity determinations can now be performed on III-V and II-VI semiconductors.


Author(s):  
E. Silva ◽  
R. Scozia

The purpose in obtaining zone axis pattern map (zap map) from a given material is to provide a quick and reliable tool to identify cristaline phases, and crystallographic directions, even in small particles. Bend contours patterns and Kossel lines patterns maps from Zr single crystal in the [0001] direction have been presented previously. In the present communication convergent beam electron diffraction (CBED) zap map of Zr will be shown. CBED patterns were obtained using a Philips microscope model EM300, which was set up to carry out this technique. Convergent objective upper pole piece for STEM and some electronic modifications in the lens circuits were required, furthermore the microscope was carefully cleaned and it was operated at a vacuum eminently good.CBED patterns in the Zr zap map consist of zero layer disks, showing fine details within them which correspond to intersecting set of higher order Laue zone (HOLZ) deficiency lines.


Author(s):  
S. Hillyard ◽  
Y.-P. Chen ◽  
J.D. Reed ◽  
W.J. Schaff ◽  
L.F. Eastman ◽  
...  

The positions of high-order Laue zone (HOLZ) lines in the zero order disc of convergent beam electron diffraction (CBED) patterns are extremely sensitive to local lattice parameters. With proper care, these can be measured to a level of one part in 104 in nanometer sized areas. Recent upgrades to the Cornell UHV STEM have made energy filtered CBED possible with a slow scan CCD, and this technique has been applied to the measurement of strain in In0.2Ga0.8 As wires.Semiconductor quantum wire structures have attracted much interest for potential device applications. For example, semiconductor lasers with quantum wires should exhibit an improvement in performance over quantum well counterparts. Strained quantum wires are expected to have even better performance. However, not much is known about the true behavior of strain in actual structures, a parameter critical to their performance.


Author(s):  
J.M.K. Wiezorek ◽  
H.L. Fraser

Conventional methods of convergent beam electron diffraction (CBED) use a fully converged probe focused on the specimen in the object plane resulting in the formation of a CBED pattern in the diffraction plane. Large angle CBED (LACBED) uses a converged but defocused probe resulting in the formation of ‘shadow images’ of the illuminated sample area in the diffraction plane. Hence, low-spatial resolution image information and high-angular resolution diffraction information are superimposed in LACBED patterns which enables the simultaneous observation of crystal defects and their effect on the diffraction pattern. In recent years LACBED has been used successfully for the investigation of a variety of crystal defects, such as stacking faults, interfaces and dislocations. In this paper the contrast from coherent precipitates and decorated dislocations in LACBED patterns has been investigated. Computer simulated LACBED contrast from decorated dislocations and coherent precipitates is compared with experimental observations.