High-resolution X-ray topographic images of dislocations in a silicon crystal recorded using an X-ray zooming tube

1998 ◽  
Vol 5 (3) ◽  
pp. 1079-1081
Author(s):  
Shigeru Kimura ◽  
Tatsuya Matsumura ◽  
Katsuyuki Kinoshita ◽  
Keiichi Hirano ◽  
Hiroshi Kihara

A Be-window-type X-ray zooming tube is an X-ray digital imaging system whose magnification factor of X-ray images can be easily varied from 10 to 200, and whose spatial resolution is less than 0.5 µm. This zooming tube was used as an imaging detector in double-crystal X-ray topography to obtain high-resolution images of dislocations in a silicon crystal. X-ray interference images of about 5 µm were observed even though optimal performance of the X-ray zooming tube could not be achieved. The results indicate that the X-ray zooming tube might make a good detector for X-ray topography with minor improvements in its stage structure.

2016 ◽  
Vol 23 (6) ◽  
pp. 1462-1473 ◽  
Author(s):  
Sebastian Cartier ◽  
Matias Kagias ◽  
Anna Bergamaschi ◽  
Zhentian Wang ◽  
Roberto Dinapoli ◽  
...  

MÖNCH is a 25 µm-pitch charge-integrating detector aimed at exploring the limits of current hybrid silicon detector technology. The small pixel size makes it ideal for high-resolution imaging. With an electronic noise of about 110 eV r.m.s., it opens new perspectives for many synchrotron applications where currently the detector is the limiting factor,e.g.inelastic X-ray scattering, Laue diffraction and soft X-ray or high-resolution color imaging. Due to the small pixel pitch, the charge cloud generated by absorbed X-rays is shared between neighboring pixels for most of the photons. Therefore, at low photon fluxes, interpolation algorithms can be applied to determine the absorption position of each photon with a resolution of the order of 1 µm. In this work, the characterization results of one of the MÖNCH prototypes are presented under low-flux conditions. A custom interpolation algorithm is described and applied to the data to obtain high-resolution images. Images obtained in grating interferometry experiments without the use of the absorption grating G2are shown and discussed. Perspectives for the future developments of the MÖNCH detector are also presented.


2021 ◽  
Author(s):  
Md Inzamam Ul Haque ◽  
Abhishek K Dubey ◽  
Jacob D Hinkle

Deep learning models have received much attention lately for their ability to achieve expert-level performance on the accurate automated analysis of chest X-rays. Although publicly available chest X-ray datasets include high resolution images, most models are trained on reduced size images due to limitations on GPU memory and training time. As compute capability continues to advance, it will become feasible to train large convolutional neural networks on high-resolution images. This study is based on the publicly available MIMIC-CXR-JPG dataset, comprising 377,110 high resolution chest X-ray images, and provided with 14 labels to the corresponding free-text radiology reports. We find, interestingly, that tasks that require a large receptive field are better suited to downscaled input images, and we verify this qualitatively by inspecting effective receptive fields and class activation maps of trained models. Finally, we show that stacking an ensemble across resolutions outperforms each individual learner at all input resolutions while providing interpretable scale weights, suggesting that multi-scale features are crucially important to information extraction from high-resolution chest X-rays.


2020 ◽  
Vol 10 (20) ◽  
pp. 7119
Author(s):  
Jihong Xiu ◽  
Pu Huang ◽  
Jun Li ◽  
Hongwen Zhang ◽  
Youyi Li

In recent years, applications such as marine search and rescue, border patrol, etc. require electro-optical equipment to have both high resolution and precise geographic positioning abilities. The step and stare working based on a composite control system is a preferred solution. This paper proposed a step and stare system composed of two single-axis fast steering mirrors and a two-axis gimbal. The fast steering mirrors (FSMs) realize image motion compensation and the gimbal completes pointing control. The working principle and the working mode of the system are described first. According to the imaging optical path, the algorithm and control flow of the line of sight (LOS) and image motion compensation are developed. The proposed method is verified through ground imaging and flight tests. Under the condition of flight, the pointing accuracy of the target can be controlled within 15 m. The proposed algorithm can achieve effective motion compensation and get high-resolution images. This achieves high resolution and accurate LOS simultaneously.


2011 ◽  
Vol 18 (4) ◽  
pp. 569-574 ◽  
Author(s):  
Masato Hoshino ◽  
Kentaro Uesugi ◽  
James Pearson ◽  
Takashi Sonobe ◽  
Mikiyasu Shirai ◽  
...  

An X-ray stereo imaging system with synchrotron radiation was developed at BL20B2, SPring-8. A portion of a wide X-ray beam was Bragg-reflected by a silicon crystal to produce an X-ray beam which intersects with the direct X-ray beam. Samples were placed at the intersection point of the two beam paths. X-ray stereo images were recorded simultaneously by a detector with a large field of view placed close to the sample. A three-dimensional wire-frame model of a sample was created from the depth information that was obtained from the lateral positions in the stereo image. X-ray stereo angiography of a mouse femoral region was performed as a demonstration of real-time stereo imaging. Three-dimensional arrangements of the femur and blood vessels were obtained.


Sign in / Sign up

Export Citation Format

Share Document