scholarly journals A Clinical Research on Real-Time Monitoring of Cerebral Edema After Basal Ganglia Hemorrhage Based on Near-Field Coupling Phase Shift Technology

IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 123736-123745
Author(s):  
Jian Sun ◽  
Jingbo Chen ◽  
Gen Li ◽  
Lin Xu ◽  
Jian Ren ◽  
...  
2020 ◽  
pp. 1-16
Author(s):  
Gen Li ◽  
Bo Zhang ◽  
Maoting Zhang ◽  
Qi Liu ◽  
Jie Luo ◽  
...  

BACKGROUND: As a common secondary pathophysiological process in postischemic stroke (IS), cytotoxic brain edema (CBE) is an independent factor leading to poor prognosis of patients. Near-field coupling (NFC) technology has some advantages such as non-invasive, non-contact, and unimpeded penetration of the skull. In theory, it can reflect the difference between normal and edema tissues through the near-field coupling phase shift (NFCPS) in the electromagnetic wave transmission trait. METHODS: Combining NFC detection principle and computer programming, we established a high-performance real-time monitoring system with functions such as automatic setting of measurement parameters, data acquisition, real-time filtering and dynamic waveform display. To investigate the feasibility of this system to detect CBE, a saline simulation experiment and a 24-hour real-time monitoring experiment after middle cerebral artery occlusion (MCAO) in rats were carried out. RESULTS: The results of the saline simulation experiment showed that the change of NFCPS was proportional to the increase of the simulated edema solution, and the variation range of NFCPS was more than 9∘ after 5 ml injection. In the 24-hour monitoring after MCAO, the NFCPS of the experimental group showed an overall downward trend over time an average change of -17.7868 ± 1.6325∘ and the change rate gradually decreased. The 24-hour NFCPS in the control group fluctuates slightly around the initial value, which has no obvious upward or downward trend. CONCLUSION: The intragroup and intergroup difference statistical analysis shows that NFCPS can effectively distinguish different intracranial pathophysiological states after IS. This work provides sufficient evidence and a technical basis for using NFCPS to monitor CBE in the future.


Sensors ◽  
2019 ◽  
Vol 19 (12) ◽  
pp. 2810 ◽  
Author(s):  
Amir Javan-Khoshkholgh ◽  
Aydin Farajidavar

High-resolution (HR) mapping of the gastrointestinal (GI) bioelectrical activity is an emerging method to define the GI dysrhythmias such as gastroparesis and functional dyspepsia. Currently, there is no solution available to conduct HR mapping in long-term studies. We have developed an implantable 64-channel closed-loop near-field communication system for real-time monitoring of gastric electrical activity. The system is composed of an implantable unit (IU), a wearable unit (WU), and a stationary unit (SU) connected to a computer. Simultaneous data telemetry and power transfer between the IU and WU is carried out through a radio-frequency identification (RFID) link operating at 13.56 MHz. Data at the IU are encoded according to a self-clocking differential pulse position algorithm, and load shift keying modulated with only 6.25% duty cycle to be back scattered to the WU over the inductive path. The retrieved data at the WU are then either transmitted to the SU for real-time monitoring through an ISM-band RF transceiver or stored locally on a micro SD memory card. The measurement results demonstrated successful data communication at the rate of 125 kb/s when the distance between the IU and WU is less than 5 cm. The signals recorded in vitro at IU and received by SU were verified by a graphical user interface.


PeerJ ◽  
2020 ◽  
Vol 8 ◽  
pp. e10079
Author(s):  
Jingbo Chen ◽  
Gen Li ◽  
Mingsheng Chen ◽  
Gui Jin ◽  
Shuanglin Zhao ◽  
...  

Cerebral edema (CE) is a non-specific pathological swelling of the brain secondary to any type of neurological injury. The real-time monitoring of focal CE mostly found in early stage is of great significance to reduce mortality and disability. Magnetic Induction Phase Shift (MIPS) is expected to achieve non-invasive continuous monitoring of CE. However, most existing MIPS sensors are made of hard materials which makes it difficult to accurately retrieve CE information. In this article, we designed a conformal two-coil structure and a single-coil structure, and studied their sensitivity map using finite element method (FEM). After that, the conformal MIPS sensor that is preferable for local CE monitoring was fabricated by flexible printed circuit (FPC). Next, physical experiments were conducted to investigate its performance on different levels of simulated CE solution volume, measurement distance, and bending. Subsequently, 14 rabbits were chosen to establish CE model and another three rabbits were selected as controls. The 24-hour MIPS real-time monitoring experiments was carried out to verify that the feasibility. Results showed a gentler attenuation trend of the conformal two-coil structure, compared with the single-coil structure. In addition, the novel flexible conformal MIPS sensor has a characteristic of being robust to bending according to the physical experiments. The results of animal experiments showed that the sensor can be used for CE monitoring. It can be concluded that this flexible conformal MIPS sensor is desirable for local focusing measurement of CE and subsequent multidimensional information extraction for predicting model. Also, it enables a much more comfortable environment for long-time bedside monitoring.


2008 ◽  
Vol 229 (2) ◽  
pp. 307-312 ◽  
Author(s):  
A. AMBROSIO ◽  
A. CAMPOSEO ◽  
P. MADDALENA ◽  
S. PATANÈ ◽  
M. ALLEGRINI

2006 ◽  
Vol 175 (4S) ◽  
pp. 521-521
Author(s):  
Motoaki Saito ◽  
Tomoharu Kono ◽  
Yukako Kinoshita ◽  
Itaru Satoh ◽  
Keisuke Satoh

2001 ◽  
Vol 11 (PR3) ◽  
pp. Pr3-1175-Pr3-1182 ◽  
Author(s):  
M. Losurdo ◽  
A. Grimaldi ◽  
M. Giangregorio ◽  
P. Capezzuto ◽  
G. Bruno

Sign in / Sign up

Export Citation Format

Share Document