An Experiment Investigation and FE Simulation Analysis on Elastic Traction Method Applied in the Pelvic Reduction

Author(s):  
Jixuan Liu ◽  
Ke Xu ◽  
Chunpeng Zhao ◽  
Gang Zhu ◽  
Yu Wang ◽  
...  
2012 ◽  
Vol 580 ◽  
pp. 214-217
Author(s):  
Hui Xiang Yang ◽  
Hai Zhou Weng ◽  
Yu Qing Zheng

The paper simulated integrated machine drop process by Abaqus / Explicit and extracted its displacement and strain results. We forecasted possible structural weakness and compared the results with the test results. The FE simulation analysis results were verified correct.


2010 ◽  
Vol 44-47 ◽  
pp. 3077-3085
Author(s):  
Yu Feng Xu

The finite element simulation is an engineering technology developed with the development of computer technologies, which is also an important development direction of structure design and analysis in the future. With the rapid development of computer software and hardware technologies, it is a tendency to perform the exquisite FE simulation analysis for structure by high performance computer (HPC). In this paper the exquisite FE simulation analysis of global model consisted of block elements and shell elements is performed by means of HPC based on Steel-concrete composite cable-stayed bridge. Moreover, the shrinkage and creep effect in the construction and post-construction period are considered. Besides effectively guiding the design, the high accurate analysis results indicate that it is practical to perform the refined FE simulation analysis by HPC.


2020 ◽  
Vol 90 (3) ◽  
pp. 30502
Author(s):  
Alessandro Fantoni ◽  
João Costa ◽  
Paulo Lourenço ◽  
Manuela Vieira

Amorphous silicon PECVD photonic integrated devices are promising candidates for low cost sensing applications. This manuscript reports a simulation analysis about the impact on the overall efficiency caused by the lithography imperfections in the deposition process. The tolerance to the fabrication defects of a photonic sensor based on surface plasmonic resonance is analysed. The simulations are performed with FDTD and BPM algorithms. The device is a plasmonic interferometer composed by an a-Si:H waveguide covered by a thin gold layer. The sensing analysis is performed by equally splitting the input light into two arms, allowing the sensor to be calibrated by its reference arm. Two different 1 × 2 power splitter configurations are presented: a directional coupler and a multimode interference splitter. The waveguide sidewall roughness is considered as the major negative effect caused by deposition imperfections. The simulation results show that plasmonic effects can be excited in the interferometric waveguide structure, allowing a sensing device with enough sensitivity to support the functioning of a bio sensor for high throughput screening. In addition, the good tolerance to the waveguide wall roughness, points out the PECVD deposition technique as reliable method for the overall sensor system to be produced in a low-cost system. The large area deposition of photonics structures, allowed by the PECVD method, can be explored to design a multiplexed system for analysis of multiple biomarkers to further increase the tolerance to fabrication defects.


2013 ◽  
Vol 22 (01) ◽  
pp. 07-12
Author(s):  
P. K. Zysset ◽  
D. H. Pahr

ZusammenfassungAltersbedingte Osteoporose erhöht des Frakturrisiko. Übliche Diagnoseverfahren basieren auf DXA. Leider sind diese ungenau und erklären oft nicht die Effekte von Behandlungen. Eine neue Methode zur Bestimmung der Knochenfestigkeit beginnt derzeit, sich zu etablieren – die Finite-Elemente-Methode (FEM). Diese universelle, im Bereich der Technik weit verbreitete, Methode erlaubt es, die Diagnose und den Behandlungserfolg besser vorauszusagen als DXA. CT-basierende FEModelle sind stark von der Bildauflösung abhängig. In diesem Überblicksartikel werden drei unterschiedliche Modelltypen (μCT, HRpQCT, QCT) vorgestellt und die Ergebnisse von densitometrischen und FE-Analysen verglichen. Dabei waren die FE-Ergebnisse den densitometrischen immer überlegen. Darüber hinaus erlaubt die FEM die Angabe eines biomechanischen Frakturrisikos. Dieser Vorteil der FE-Methode muss jedoch im Licht der höheren Röntgendosen und Betriebskosten der CT-Bildgebung betrachtet werden. Zukünftig wird die FE-Methode klinisch eine weite Verbreitung finden – die Frage ist nur wann und wie!


Sign in / Sign up

Export Citation Format

Share Document