The Stability of Dental Alloys in the Oral Environment

Author(s):  
Adina Oana Armencia ◽  
Roxana Ionela Vasluianu ◽  
Dana Gabriela Budala ◽  
Dragos Vicoveanu ◽  
Dragos Ioan Virvescu ◽  
...  
2012 ◽  
Vol 23 (2) ◽  
pp. 141-148 ◽  
Author(s):  
Rodrigo Galo ◽  
Ricardo Faria Ribeiro ◽  
Renata Cristina Silveira Rodrigues ◽  
Luís Augusto Rocha ◽  
Maria da Glória Chiarello de Mattos

The aim of this study was to determine the effect of the oral environment on the corrosion of dental alloys with different compositions, using electrochemical methods. The corrosion rates were obtained from the current-potential curves and electrochemical impedance spectroscopy (EIS). The effect of artificial saliva on the corrosion of dental alloys was dependent on alloy composition. Dissolution of the ions occurred in all tested dental alloys and the results were strongly dependent on the general alloy composition. Regarding the alloys containing nickel, the Ni-Cr and Ni-Cr-Ti alloys released 0.62 mg/L of Ni on average, while the Co-Cr dental alloy released ions between 0.01 and 0.03 mg/L of Co and Cr, respectively.The open-circuit potential stabilized at a higher level with lower deviation (standard deviation: Ni-Cr-6Ti = 32 mV/SCE and Co-Cr = 54 mV/SCE). The potenciodynamic curves of the dental alloys showed that the Ni-based dental alloy with >70 wt% of Ni had a similar curve and the Co-Cr dental alloy showed a low current density and hence a high resistance to corrosion compared with the Ni-based dental alloys. Some changes in microstructure were observed and this fact influenced the corrosion behavior for the alloys. The lower corrosion resistance also led to greater release of nickel ions to the medium. The quantity of Co ions released from the Co-Cr-Mo alloy was relatively small in the solutions. In addition, the quantity of Cr ions released into the artificial saliva from the Co-Cr alloy was lower than Cr release from the Ni-based dental alloys.


Materials ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 4949
Author(s):  
Carmen Marina Garcia-Falcon ◽  
Tomas Gil-Lopez ◽  
Amparo Verdu-Vazquez ◽  
Julia Claudia Mirza-Rosca

Nickel-based and cobalt-based metal alloys are frequently used in dentistry. The introduction of various elements in the alloy changes its characteristics, and a thorough study of each alloy should be completed to determine its appropriate corrosion resistance and biocompatibility in contact with physiological fluids. There are scarce investigations on these widely used dental alloys in Ringer solution, and findings in this research bring new experimental data and information. The present study evaluated and compared the corrosion behavior of six NiCr- and two CoCr-based dental materials in Ringer solution, using the following techniques: potentiostatic polarization curves (chronoamperometry), microstructural analysis, and EIS (electrochemical impedance spectroscopy). The results obtained in this investigation showed that in the NiCr-based specimens Ni4, Ni5, and Ni6 the stability of the passive layer was destroyed after polarization and a development and growth of stable pits was found in the microstructural analysis after electrochemical treatment. In terms of susceptibility to corrosion, two different groups of specimens were derived from this investigation. A first group which included the two CoCr (Co1 and Co2) and three of the six NiCr alloys studied (Ni1, Ni2, and Ni3). A second group with the other NiCr alloys investigated Ni4, Ni5, and Ni6.


1993 ◽  
Vol 42 (11) ◽  
pp. 734-741 ◽  
Author(s):  
Kazuhiko Endo ◽  
Koichi Matsuda ◽  
Hiroki Ohno

2001 ◽  
Vol 42 (2) ◽  
pp. 350-355 ◽  
Author(s):  
Yoshimitsu Okazaki ◽  
Emiko Nishimura

Sign in / Sign up

Export Citation Format

Share Document