The modified single input Op-Amps memristor based oscillator

Author(s):  
A. H. ElSamman ◽  
A. G. Radwan ◽  
A. H. Madian
Keyword(s):  
Op Amps ◽  
2020 ◽  
Vol 12 (3) ◽  
pp. 168-174
Author(s):  
Rashmi Sahu ◽  
Maitraiyee Konar ◽  
Sudip Kundu

Background: Sensing of biomedical signals is crucial for monitoring of various health conditions. These signals have a very low amplitude (in μV) and a small frequency range (<500 Hz). In the presence of various common-mode interferences, biomedical signals are difficult to detect. Instrumentation amplifiers (INAs) are usually preferred to detect these signals due to their high commonmode rejection ratio (CMRR). Gain accuracy and CMRR are two important parameters associated with any INA. This article, therefore, focuses on the improvement of the gain accuracy and CMRR of a low power INA topology. Objective: The objective of this article is to achieve high gain accuracy and CMRR of low power INA by having high gain operational amplifiers (Op-Amps), which are the building blocks of the INAs. Methods: For the implementation of the Op-Amps and the INAs, the Cadence Virtuoso tool was used. All the designs and implementation were realized in 0.18 μm CMOS technology. Results: Three different Op-Amp topologies namely single-stage differential Op-Amp, folded cascode Op-Amp, and multi-stage Op-Amp were implemented. Using these Op-Amp topologies separately, three Op-Amp-based INAs were realized and compared. The INA designed using the high gain multistage Op-Amp topology of low-frequency gain of 123.89 dB achieves a CMRR of 164.1 dB, with the INA’s gain accuracy as good as 99%, which is the best when compared to the other two INAs realized using the other two Op-Amp topologies implemented. Conclusion: Using very high gain Op-Amps as the building blocks of the INA improves the gain accuracy of the INA and enhances the CMRR of the INA. The three Op-Amp-based INA designed with the multi-stage Op-Amps shows state-of-the-art characteristics as its gain accuracy is 99% and CMRR is as high as 164.1 dB. The power consumed by this INA is 29.25 μW by operating on a power supply of ±0.9V. This makes this INA highly suitable for low power measurement applications.


2020 ◽  
Vol 96 (3s) ◽  
pp. 137-140
Author(s):  
А.А. Лебедев ◽  
А.С. Будяков ◽  
Е.М. Савченко

Рассматриваются два варианта построения интегральных ОУ: 1) промышленных ОУ типа LM124, не уязвимых к воздействию ТЗЧ; 2) быстродействующих ОУ с улучшенными точностными и скоростными характеристиками. В обоих случаях используется синергетический подход, основанный на введении в структуру аналога элемента с режимом обострения. Two options for the construction of integrated op-amps are considered: 1) industrial op-amps of the LM124 type, which are invulnerable to the effects of HCP; 2) high-speed op-amps with improved accuracy and speed characteristics. In both cases, a synergistic approach is used, based on the introduction of an element with an aggravation mode into the structure of the analogue.


Author(s):  
Abiodun Ogunseye ◽  
Daniel Ogheneovo Johnson

A power inverter circuits is normally designed to meet its design specifications when the applied input DC voltage is within specified tolerance limits. Thus, single input inverters are usually specified to work from a DC source having a fixed nominal voltage. This limits the usefulness of the inverter circuit when a DC source having the specified nominal voltage is not available. In this work, a modified square wave inverter system that is specified to work properly from batteries with nominal voltages of 6, 12, 18 and 24 V was designed.  A model of the microcontroller-based circuit was developed with Proteus® software and its firmware was written in C language using the MicroC® development tool. A prototype of the circuit was constructed and then tested.  The constructed circuit was found to work properly by producing a 50 Hz modified square waveform when it was powered from batteries having nominal voltages of 6 V, 12 V, 18 V and 24 V.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Varun Srivastava ◽  
Abhilash Mandloi ◽  
Dhiraj Kumar Patel

AbstractFree space optical (FSO) communication refers to a line of sight technology, which comprises optical source and detector to create a link without the use of physical connections. Similar to other wireless communication links, these are severely affected by losses that emerged due to atmospheric turbulence and lead to deteriorated intensity of the optical signal at the receiver. This impairment can be compensated easily by enhancing the transmitter power. However, increasing the transmitter power has some limitations as per radiation regulations. The requirement of high transmit power can be reduced by employing diversity methods. This paper presents, a wavelength-based diversity method with equal gain combining receiver, an effective technique to provide matching performance to single input single output at a comparatively low transmit power.


Sign in / Sign up

Export Citation Format

Share Document