The Study of Electric Field and Partial Discharges on XLPE Insulation under DC High Voltage using COMSOL Multiphysics

Author(s):  
Apoorva Sahu ◽  
Rakesh Sahoo ◽  
Subrata Karmakar
Energies ◽  
2020 ◽  
Vol 13 (18) ◽  
pp. 4830
Author(s):  
Alper Aydogan ◽  
Fatih Atalar ◽  
Aysel Ersoy Yilmaz ◽  
Pawel Rozga

In high-voltage equipment, it is vital to detect any failure in advance. To do this, a determination of the partial discharges occurring at different voltage types as well as at different electrode configurations is essential for observing the oil condition. In this study, an experimental setup consisting of a needle–semi-sphere electrode configuration immersed in mineral oil is prepared for laboratory experiment. In such a way, a non-uniform electric field is created and the leakage currents are monitored from the grounded electrode. A total of six different electrode configurations are analyzed during the tests by the use of hemispheres of different diameters as grounded electrodes and copper and steel pointed (medical) needle high-voltage electrodes. In the experiments, the partial discharges occurring at four different voltage levels between 5.4 and 10.8 kV are measured and recorded. The effect of the different electrode configurations and voltage levels on the harmonic distortion are noted and discussed. It is experimentally confirmed that it is possible to measure the leakage current caused by the partial discharges of the corona type in oil at the different metal points, creating high-voltage electrodes and different electric field distributions based on the proposed non-invasive measurement technique. The studies showed that there is a significant rise of even harmonic components in the leakage current during the increase in the partial discharge intensity with the 5th harmonic as dominant.


2021 ◽  
Vol 16 (95) ◽  
pp. 126-135
Author(s):  
Evgeniy S. Andreenkov ◽  
◽  
Vaclav E. Skorubskiy ◽  
Sergey A. Shunaev ◽  
◽  
...  

The article discusses the main aspects of modeling suspended polymer high-voltage insulation of overhead power lines (PTL) in the COMSOL Multiphysics 5.6 software package. Analytical expressions of the mathematical model of the electromagnetic field around the insulator are given, on the basis of which a numerical solution is formed within the software package that allows you to build a model of the electric field in two-dimensional and three-dimensional space. There are three main stages of working with the program interface. At the first stage, the task of the geometric dimensions of the model and the surrounding area is considered, attention is paid to the formation of the design features of polymer insulators. In the second stage, the physical properties of the structural materials of the insulator, as well as the surrounding space, are described. The third stage is reduced to the determination of boundary conditions for solving the Poisson differential equation. Recommendations for finite element mesh density are given. A gradient picture of the distribution of the electric potential near the surface of the insulator is presented. The graphs of the distribution of the normal component of the electric field strength along the surface of the insulator are also plotted. On the basis of the obtained results, the influence of external factors on the properties of the polymer insulator is studied. A possible variant of modeling influencing factors, such as pollution and moisture, by making changes in the description of the physical properties of the insulator surface, namely by including a uniform and continuous layer with a given conductivity, is described. The distribution of the normal component of the electric field strength along the surface of the insulator with contamination is obtained. The results of modeling the electric field distribution with the presence of contamination on the surface of the insulator and its absence are summarized in the table where the electric field strength is indicated depending on the distance to the traverse. Based on the analysis of the results obtained, an assumption is made about the overestimated level of the maximum electric field on the insulators recommended by the manufacturers. The convergence of the considered models with the experimental data obtained in the course of long-term observation of the dynamics of the degradation and aging processes of the surface of polymer suspended insulators of overhead transmission lines is discussed.


Jurnal Teknik ◽  
2018 ◽  
Vol 7 (1) ◽  
Author(s):  
Mauludi Manfaluthy

WHO (World Health Organization) concludes that not much effect is caused by electric field up to 20 kV / m in humans. WHO standard also mentions that humans will not be affected by the magnetic field under  100 micro tesla and that the electric field will affect the human body with a maximum standard of 5,000 volts per meter. In this study did not discuss about the effect of high voltage radiation SUTT (High Voltage Air Channel) with human health. The research will focus on energy utilization of SUTT radiation. The combination of electric field and magnetic field on SUTT (70-150KV) can generate electromagnetic (EM) and radiation waves, which are expected to be converted to turn on street lights around the location of high voltage areas or into other forms. The design of this prototype works like an antenna in general that captures electromagnetic signals and converts them into AC waves. With a capacitor that can store the potential energy of AC and Schottky diode waves created specifically for low frequency waves, make the current into one direction (DC). From the research results obtained the current generated from the radiation is very small even though the voltage is big enough.Keywords : Radiance Energy, Joule Thief, and  LED Module.


1983 ◽  
Vol 26 (1) ◽  
pp. 49-50
Author(s):  
I. P. Klimashevskii ◽  
B. L. Kondrat'ev ◽  
V. A. Poletaev ◽  
V. M. Yurkevich

Sign in / Sign up