Fault location of cable insulation based on acoustic — Magnetic synchronization method

Author(s):  
Ting Lin ◽  
Qiang Zhou
2012 ◽  
Vol 132 (10) ◽  
pp. 872-878
Author(s):  
Junya Matsuki ◽  
Hisao Taoka ◽  
Shoji Kawasaki ◽  
Yuki Nakajima ◽  
Masakazu Horime ◽  
...  
Keyword(s):  

2019 ◽  
Vol 11 ◽  
pp. 33-39
Author(s):  
Yury Ya. LYAMETS ◽  
◽  
Mikhail V. MARTYNOV ◽  
Alexander N. MASLOV ◽  
◽  
...  

2017 ◽  
Vol 5 (3) ◽  
pp. 17
Author(s):  
SANAD A. AHMED ◽  
ATTIA MAHMOUD A. ◽  
HAMED NABIL M. ◽  
ABDELAZIZ ALMOATAZ Y. ◽  
◽  
...  

Author(s):  
Chris Eddleman ◽  
Nagesh Tamarapalli ◽  
Wu-Tung Cheng

Abstract Yield analysis of sub-micron devices is an ever-increasing challenge. The difficulty is compounded by the lack of in-line inspection data as many companies adopt foundry or fab-less models for acquiring wafers. In this scenario, failure analysis is increasingly critical to help drive yields. Failure analysis is a process of fault isolation, or a method of isolating failures as precisely as possible followed by identification of a physical defect. As the number of transistors and metal layers increase, traditional fault isolation techniques are less successful at isolating a cause of failures. Costs are increasing due to the amount of time needed to locate the physical defect. One solution to the yield analysis problem is scan diagnosis based fault isolation. Previous scan diagnosis based techniques were limited with little information about the type of fault and confidence of diagnosis. With new scan diagnosis algorithms it is now possible to not only isolate, but to identify the type of fault as well as assigning a confidence ranking prior to any destructive analysis. This paper presents multiple case studies illustrating the application of scan diagnosis as an effective means to achieve yield enhancement. The advanced scan diagnostic tool used in this study provides information about the fault type as well as fault location. This information focuses failure analysis efforts toward a suspected defect, decreasing the cycle time required to determine root cause, as well as increasing the over all success rate.


Author(s):  
Dima A. Smolyansky

Abstract The visual nature of Time Domain Reflectometry (TDR) makes it a very natural technology that can assist with fault location in BGA packages, which typically have complex interweaving layouts that make standard failure analysis techniques, such as acoustic imaging and X-ray, less effective and more difficult to utilize. This article discusses the use of TDR for package failure analysis work. It analyzes in detail the TDR impedance deconvolution algorithm as applicable to electronic packaging fault location work, focusing on the opportunities that impedance deconvolution and the resulting true impedance profile opens up for such work. The article examines the TDR measurement accuracy and the comparative package failure analysis, and presents three main considerations for package failure analysis. It also touches upon the goal and the task of the failure analysts and TDR's specific signatures for the open and short connections.


Author(s):  
Lény Baczkowski ◽  
Franck Vouzelaud ◽  
Dominique Carisetti ◽  
Nicolas Sarazin ◽  
Jean-Claude Clément ◽  
...  

Abstract This paper shows a specific approach based on infrared (IR) thermography to face the challenging aspects of thermal measurement, mapping, and failure analysis on AlGaN/GaN high electron-mobility transistors (HEMTs) and MMICs. In the first part of this paper, IR thermography is used for the temperature measurement. Results are compared with 3D thermal simulations (ANSYS) to validate the thermal model of an 8x125pm AIGaN/GaN HEMT on SiC substrate. Measurements at different baseplate temperature are also performed to highlight the non-linearity of the thermal properties of materials. Then, correlations between the junction temperature and the life time are also discussed. In the second part, IR thermography is used for hot spot detection. The interest of the system for defect localization on AIGaN/GaN HEMT technology is presented through two case studies: a high temperature operating life test and a temperature humidity bias test.


Sign in / Sign up

Export Citation Format

Share Document