A comparison of embroidered and woven textile electrodes for continuous measurement of ECG

Author(s):  
Tomas Bystricky ◽  
Daniela Moravcova ◽  
Petr Kaspar ◽  
Radek Soukup ◽  
Ales Hamacek
Biosensors ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 331
Author(s):  
Katya Arquilla ◽  
Laura Devendorf ◽  
Andrea K. Webb ◽  
Allison P. Anderson

Wearable physiological monitoring systems are becoming increasingly prevalent in the push toward autonomous health monitoring and offer new modalities for playful and purposeful interaction within human computer interaction (HCI). Sensing systems that can be integrated into garments and, therefore, daily activities offer promising pathways toward ubiquitous integration. The electrocardiogram (ECG) signal is commonly monitored in healthcare and is increasingly utilized as a method of determining emotional and psychological state; however, the complete ECG waveform with the P, Q, R, S, and T peaks is not commonly used, due to the challenges associated with collecting the full waveform with wearable systems. We present woven textile electrodes as an option for garment-integrated ECG monitoring systems that are capable of capturing the complete ECG waveform. In this work, we present the changes in the peak detection performance caused by different sizes, patterns, and thread types with data from 10 human participants. These testing results provide empirically-derived guidelines for future woven textile electrodes, present a path forward for assessing design decisions, and highlight the importance of testing novel wearable sensor systems with more than a single individual.


1970 ◽  
Vol 13 (1) ◽  
pp. 65-73 ◽  
Author(s):  
Mary Mira

Listening, a significant dimension of the behavior of hearing-impaired children, may be measured directly by recording childrens' responses to obtain audio narrations programmed via a conjugate reinforcement system. Twelve hearing-impaired, school-aged children responded in varying ways to the opportunity to listen. Direct and continuous measurement of listening has relevance for evaluation of remediation methods and for discovery of variables potentially related to listening.


2013 ◽  
pp. 1-1
Author(s):  
Ragini C Bhake ◽  
Jack A Leendertz ◽  
Astrid C E Linthorst ◽  
Stafford L Lightman

1997 ◽  
Vol 36 (4) ◽  
pp. 307-312
Author(s):  
Michael R. Rasmussen ◽  
Torben Larsen

An on-line settling column for measuring the dynamic variations of settling velocity of activated sludge has been developed. The settling column is automatic and self-cleansing insuring continuous and reliable measurements. The settling column was tested on sludge from a batch reactor where sucrose was added as an impulse to activated sludge. The continuous measurement of settling velocity revealed a highly dynamic response after the sucrose was added. The results were verified with simultaneous measurement of the initial settling rate. A 200 hour experiment showed variations in settling velocity, which was not apparent in the DSVI (Diluted Sludge Volume Index).


2010 ◽  
Vol 14 (4) ◽  
pp. 81-88 ◽  
Author(s):  
Antonio Lanatà ◽  
Gaetano Valenza ◽  
E.Pasquale Scilingo

Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1578
Author(s):  
Luisa Euler ◽  
Li Guo ◽  
Nils-Krister Persson

Textile electrodes, also called textrodes, for biosignal monitoring as well as electrostimulation are central for the emerging research field of smart textiles. However, so far, only the general suitability of textrodes for those areas was investigated, while the influencing parameters on the contact impedance related to the electrode construction and external factors remain rather unknown. Therefore, in this work, six different knitted electrodes, applied both wet and dry, were compared regarding the influence of specific knitting construction parameters on the three-electrode contact impedance measured on a human forearm. Additionally, the influence of applying pressure was investigated in a two-electrode setup using a water-based agar dummy. Further, simulation of an equivalent circuit was used for quantitative evaluation. Indications were found that the preferred electrode construction to achieve the lowest contact impedance includes a square shaped electrode, knitted with a high yarn density and, in the case of dry electrodes, an uneven surface topography consisting of loops, while in wet condition a smooth surface is favorable. Wet electrodes are showing a greatly reduced contact impedance and are therefore to be preferred over dry ones; however, opportunities are seen for improving the electrode performance of dry electrodes by applying pressure to the system, thereby avoiding disadvantages of wet electrodes with fluid administration, drying-out of the electrolyte, and discomfort arising from a “wet feeling”.