Monitoring of Microfluidics Systems for PET Radiopharmaceutical Synthesis Using Integrated Silicon Photomultipliers

2019 ◽  
Vol 19 (17) ◽  
pp. 7702-7707 ◽  
Author(s):  
Blas Salvador ◽  
Diego Andres Escalante Pineda ◽  
Laura Fernandez-Maza ◽  
Ariadna Corral ◽  
Sergio Camacho-Leon ◽  
...  
Author(s):  
Simona Malaspina ◽  
Vesa Oikonen ◽  
Anna Kuisma ◽  
Otto Ettala ◽  
Kalle Mattila ◽  
...  

Abstract Purpose This phase 1 open-label study evaluated the uptake kinetics of a novel theranostic PET radiopharmaceutical, 18F-rhPSMA-7.3, to optimise its use for imaging of prostate cancer. Methods Nine men, three with high-risk localised prostate cancer, three with treatment-naïve hormone-sensitive metastatic disease and three with castration-resistant metastatic disease, underwent dynamic 45-min PET scanning of a target area immediately post-injection of 300 MBq 18F-rhPSMA-7.3, followed by two whole-body PET/CT scans acquired from 60 and 90 min post-injection. Volumes of interest (VoIs) corresponding to prostate cancer lesions and reference tissues were recorded. Standardised uptake values (SUV) and lesion-to-reference ratios were calculated for 3 time frames: 35–45, 60–88 and 90–118 min. Net influx rates (Ki) were calculated using Patlak plots. Results Altogether, 44 lesions from the target area were identified. Optimal visual lesion detection started 60 min post-injection. The 18F-rhPSMA-7.3 signal from prostate cancer lesions increased over time, while reference tissue signals remained stable or decreased. The mean (SD) SUV (g/mL) at the 3 time frames were 8.4 (5.6), 10.1 (7) and 10.6 (7.5), respectively, for prostate lesions, 11.2 (4.3), 13 (4.8) and 14 (5.2) for lymph node metastases, and 4.6 (2.6), 5.7 (3.1) and 6.4 (3.5) for bone metastases. The mean (SD) lesion-to-reference ratio increases from the earliest to the 2 later time frames were 40% (10) and 59% (9), respectively, for the prostate, 65% (27) and 125% (47) for metastatic lymph nodes and 25% (19) and 32% (30) for bone lesions. Patlak plots from lesion VoIs signified almost irreversible uptake kinetics. Ki, SUV and lesion-to-reference ratio estimates showed good agreement. Conclusion 18F-rhPSMA-7.3 uptake in prostate cancer lesions was high. Lesion-to-background ratios increased over time, with optimal visual detection starting from 60 min post-injection. Thus, 18F-rhPSMA-7.3 emerges as a very promising PET radiopharmaceutical for diagnostic imaging of prostate cancer. Trial Registration NCT03995888 (24 June 2019).


Author(s):  
Mst Shamim Ara Shawkat ◽  
Md Sakib Hasan ◽  
Nicole McFarlane

Instruments ◽  
2021 ◽  
Vol 5 (2) ◽  
pp. 18
Author(s):  
Fabio Acerbi ◽  
Anurag Behera ◽  
Alberto Dalla Mora ◽  
Laura Di Sieno ◽  
Alberto Gola

Silicon photomultipliers (SiPM) are pixelated single-photon detectors combining high sensitivity, good time resolution and high dynamic range. They are emerging in many fields, such as time-domain diffuse optics (TD-DO). This is a promising technique in neurology, oncology, and quality assessment of food, wood, and pharmaceuticals. SiPMs can have very large areas and can significantly increase the sensitivity of TD-DO in tissue investigation. However, such improvement is currently limited by the high detector noise and the worsening of SiPM single-photon time resolution due to the large parasitic capacitances. To overcome such limitation, in this paper, we present two single-photon detection modules, based on 6 × 6 mm2 and 10 × 10 mm2 SiPMs, housed in vacuum-sealed TO packages, cooled to −15 °C and −36 °C, respectively. They integrate front-end amplifiers and temperature controllers, being very useful instruments for TD-DO and other biological and physical applications. The signal extraction from the SiPM was improved. The noise is reduced by more than two orders of magnitude compared to the room temperature level. The full suitability of the proposed detectors for TD-DO measurements is outside the scope of this work, but preliminary tests were performed analyzing the shape and the stability of the Instrument Response Function. The proposed modules are thus fundamental building blocks to push the TD-DO towards deeper investigations inside the body.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Julien Salvadori ◽  
Freddy Odille ◽  
Gilles Karcher ◽  
Pierre-Yves Marie ◽  
Laetitia Imbert

Abstract Purpose Digital PET involving silicon photomultipliers (SiPM) provides an enhanced time-of-flight (TOF) resolution as compared with photomultiplier (PMT)-based PET, but also a better prevention of the count-related rises in dead time and pile-up effects mainly due to smaller trigger domains (i.e., the detection surfaces associated with each trigger circuit). This study aimed to determine whether this latter property could help prevent against deteriorations in TOF resolution and TOF image quality in the wide range of PET count rates documented in clinical routine. Methods Variations, according to count rates, in timing resolution and in TOF-related enhancement of the quality of phantom images were compared between the first fully digital PET (Vereos) and a PMT-based PET (Ingenuity). Single-count rate values were additionally extracted from the list-mode data of routine analog- and digital-PET exams at each 500-ms interval, in order to determine the ranges of routine PET count rates. Results Routine PET count rates were lower for the Vereos than for the Ingenuity. For Ingenuity, the upper limits were estimated at approximately 21.7 and 33.2 Mcps after injection of respectively 3 and 5 MBq.kg-1 of current 18F-labeled tracers. At 5.8 Mcps, corresponding to the lower limit of the routine count rates documented with the Ingenuity, timing resolutions provided by the scatter phantom were 326 and 621 ps for Vereos and Ingenuity, respectively. At higher count rates, timing resolution was remarkably stable for Vereos but exhibited a progressive deterioration for Ingenuity, respectively reaching 732 and 847 ps at the upper limits of 21.7 and 33.2 Mcps. The averaged TOF-related gain in signal/noise ratio was stable at approximately 2 for Vereos but decreased from 1.36 at 5.8 Mcps to 1.14 and 1.00 at respectively 21.7 and 33.2 Mcps for Ingenuity. Conclusion Contrary to the Ingenuity PMT-based PET, the Vereos fully digital PET is unaffected by any deterioration in TOF resolution and consequently, in the quality of TOF images, in the wide range of routine PET count rates. This advantage is even more striking with higher count-rates for which the preferential use of digital PET should be further recommended (i.e., dynamic PET recording, higher injected activities).


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Vincent D. Ching-Roa ◽  
Eben M. Olson ◽  
Sherrif F. Ibrahim ◽  
Richard Torres ◽  
Michael G. Giacomelli

An amendment to this paper has been published and can be accessed via a link at the top of the paper.