Dual Current Control Loops for Three-Phase Four-Leg Grid-Connected Inverter using Complex-Vector Form

Author(s):  
Ming Yang ◽  
Wu Cao ◽  
Jianfeng Zhao ◽  
Jing Song ◽  
Li Wei
IEEE Access ◽  
2020 ◽  
Vol 8 ◽  
pp. 876-888
Author(s):  
Yuanbin He ◽  
Bangchao Wang ◽  
Xiaogao Xie ◽  
Lei Shen ◽  
Pingliang Zeng

Energies ◽  
2019 ◽  
Vol 12 (19) ◽  
pp. 3676
Author(s):  
Chuanyue Li ◽  
Taoufik Qoria ◽  
Frederic Colas ◽  
Jun Liang ◽  
Wenlong Ming ◽  
...  

The dq impedance stability analysis for a grid-connected current-control inverter is based on the impedance ratio matrix. However, the coupled matrix brings difficulties in deriving its eigenvalues for the analysis based on the general Nyquist criterion. If the couplings are ignored for simplification, unacceptable errors will be present in the analysis. In this paper, the influence of the couplings on the dq impedance stability analysis is studied. To take the couplings into account simply, the determinant-based impedance stability analysis is used. The mechanism between the determinant of the impedance-ratio matrix and the inverter stability is unveiled. Compared to the eigenvalues-based analysis, only one determinant rather than two eigenvalue s-function is required for the stability analysis. One Nyquist plot or pole map can be applied to the determinant to check the right-half-plane poles. The accuracy of the determinant-based stability analysis is also checked by comparing with the state-space stability analysis method. For the stability analysis, the coupling influence on the current control, the phase-locked loop, and the grid impedance are studied. The errors can be 10% in the stability analysis if the couplings are ignored.


2012 ◽  
Vol 241-244 ◽  
pp. 636-640
Author(s):  
Wu Wu Tang ◽  
Liang Liang Chen ◽  
Hong Xu Yin ◽  
Hao Dong

This paper developed a mathematical model of three-phase PV grid-connected inverter, and studied the grid-connected current control method based on PI control in synchronous rotating reference frame. Simulation and experimental results from the prototype of 30kW three-phase PV grid-connected inverter proved the correctness and the feasibility of the control strategy, and this grid-connected inverter can operate at the unity power factor state with a nice dynamic performance, and the output current has high sinusoidal and low harmonic content as well as good symmetry.


2021 ◽  
Vol 11 (7) ◽  
pp. 3170
Author(s):  
Yahui Li ◽  
Jing Zhang ◽  
Zhenghang Hao ◽  
Peng Tian

Aiming at the problem of power coupling and complicated decoupling in the d-q coordinate system of a three-phase grid-connected inverter, a current closed-loop control strategy based on an improved QPIR (quasi-proportional integral resonant) controller in the α-β two-phase static coordinate system is proposed. Firstly, the mathematical model of an LCL three-phase grid-connected inverter is established, and its instantaneous power calculation equation is deduced. Secondly, the frequency method is applied to compare and analyze the proportional resonant, quasi-proportional resonant, and improved current controller, and the appropriate improved controller parameters are obtained according to the traditional proportional integral controller parameter design method and the weight coefficient. Finally, the improved controller is compared with the traditional controller in the simulation model of the LCL three-phase grid-connected inverter based on active damping. The results show that the proposed improved current control strategy has good dynamic response characteristics, can realize the non-static error control of grid-connected current, and realizes the decoupling control of active power and reactive power when the load jumps. At the same time, the results also prove the superiority of the proposed control strategy and verify its effectiveness.


2012 ◽  
Vol 614-615 ◽  
pp. 1578-1582
Author(s):  
Chun Qing Qi ◽  
Yi Ruan ◽  
Feng Wen Cao

This paper proposes a control strategy,based on the grid voltage oriented vector control (VOC), which makes three-phase inverter control the active and reactive power of grid-connected inverter under the premise of the direct current control. This paper analyzes the principle of three phase photovoltaic grid connected inverter and describes the control structure of the inverter. The control strategy can overcome the deficiencies of the indirect current control scheme. This paper designs the current closed-loop control system, which not only improve the system dynamic response speed and output current waveform quality, while also reduce its sensitivity to parameter changes to improve the robustness of the system. The simulation results show the validity of control strategy proposed.


2018 ◽  
Vol 2018 ◽  
pp. 1-13 ◽  
Author(s):  
Ling Yang ◽  
Yandong Chen ◽  
An Luo ◽  
Kunshan Huai ◽  
Leming Zhou ◽  
...  

In the grid-connected inverter based on the deadbeat current control, the filter inductance variation and single update PWM affect the distortion of the grid current, stability, and dynamic of the system. For this, a double update PWM method for the deadbeat current controller in three-phase grid-connected system is proposed, which not only effectively decreases the grid current distortion and control delay, but also improves the system stability and dynamic response speed due to reducing the characteristic root equation order of the closed-loop transfer function. The influence of the filter inductance deviation coefficient on the system performance is analyzed. As a conclusion, the corresponding filter inductance deviation coefficient in the system critical stability increases with increase in the parasitic resistance of the filter inductance and line equivalent resistance and decreases with increase in the sampling frequency. Considering the system stability and dynamic response, the optimal range of the control parameters is acquired. Simulation and experimental results verify the effectiveness of the proposed method.


Sign in / Sign up

Export Citation Format

Share Document