A linear and decoupled control strategy for VSC based HVDC system

Author(s):  
Guibin Zhang ◽  
Zheng Xu ◽  
Guan Wang
2013 ◽  
Vol 3 (2) ◽  
Author(s):  
Guo-Jie Li ◽  
Si-Ye Ruan ◽  
Tek Lie

AbstractA multi-terminal voltage-source-converter (VSC) based high voltage direct current (HVDC) system is concerned for its flexibility and reliability. In this study, a control strategy for multiple VSCs is proposed to auto-share the real power variation without changing control mode, which is based on “dc voltage droop” power regulation functions. With the proposed power regulation design, the multiple VSCs automatically share the real power change and the VSC-HVDC system is stable even under loss of any one converter while there is no overloading for any individual converter. Simulation results show that it is effective to balance real power for power disturbance and thus improves operation reliability for the multi-terminal VSC-HVDC system by the proposed control strategy.


A reliable grid connected Photovoltaic (PV) system require effective control schemes for efficient use of solar energy. This paper presents a three-phase grid tied PV system with decoupled real and reactive power control to achieve desired power factor with Maximum Power Point Tracking (MPPT) controller to get maximum solar energy. The synchronous reference frame (dq) control along with decoupling concept is used to control the DC-AC inverter output, while the Phase Locked Loop (PLL) synchronization technique is used to monitor and synchronize the voltage and current at the grid side. The DC-DC converter with Incremental Conductance (InC) based MPPT model is also designed in this paper due to better accuracy compared to Perturb & Observe (P&O) algorithm. The simulation is performed in MATLAB/SIMULINK and a 31.5 kW PV system is modelled to get 30 kW power with the help of MPPT at Standard Test Conditions (STC). Any power factor value between 0.85 lagging to 0.9 leading can be obtained by changingreference q current in this inverter control strategy. The simulation results show that the change of reactive powerdoes not affecttheactive power values of the system, which verifies the effectiveness of the decoupled control strategy of the inverter.


2019 ◽  
Vol 11 (5) ◽  
pp. 1232 ◽  
Author(s):  
Md Alam ◽  
Mohammad Abido ◽  
Alaa Hussein ◽  
Ibrahim El-Amin

This paper proposes a non-superconducting bridge-type fault current limiter (BFCL) as a potential solution to the fault problems of doubly fed induction generator (DFIG) integrated voltage source converter high-voltage DC (VSC-HVDC) transmission systems. As the VSC-HVDC and DFIG systems are vulnerable to AC/DC faults, a BFCL controller is developed to insert sizeable impedance during the inception of system disturbances. In the proposed control scheme, constant capacitor voltage is maintained by the stator VSC (SVSC) controller, while current extraction or injection is achieved by rotor VSC (RVSC) controller. Current control mode-based active and reactive power controllers for an HVDC system are developed. Balanced and different unbalanced faults are applied in the system to show the effectiveness of the proposed BFCL solution. A DFIG wind-based VSC-HVDC system, BFCL, and their controllers are implemented in a real time digital simulator (RTDS). The performance of the proposed BFCL control strategy in DFIG-based VSC-HVDC system is compared with a series dynamic braking resistor (SDBR). Comparative RTDS implementation results show that the proposed BFCL control strategy is very efficient in improving system fault ride through (FRT) capability and outperforms SDBR in all cases considered.


Author(s):  
Xiaoyun Wei ◽  
Hui Sun ◽  
Xiaoguang Wei ◽  
Qian Ma ◽  
Fengge Xu

This paper presents a novel unified dynamic model and control strategy to improve the power quality for VSC based high voltage direct current transmission system (VSC-HVDC) under unbalanced grid conditions. The unified models present the dynamic behavior of VSC-HVDC in the unique positive synchronously rotating reference (dq-p) frame with respect to both the positive- and negative-sequence components. Based on the unified model, a strategy to either eliminate the dc-link ripple or achieve the balanced currents, along with a rather low level harmonics in each grid is introduced by resorting to the resonant integrator and filter based scheme in the two cascaded control loops. The resonant integrator and filter scheme enables effective control of the positive- and negative-sequence currents, and avoid the sequence component decomposition. The simulation studies in PSCAD/EMTDC verify the improved performance of VSC-HVDC system regarding the power quality and the ride-through capability.


Sign in / Sign up

Export Citation Format

Share Document