A phase-matching based phase center determination method for OATS antenna calibration

Author(s):  
Zhenfei Song ◽  
Ming Xie ◽  
Weilong Wang ◽  
Xiaoxun Gao
2021 ◽  
Author(s):  
Gregor Moeller ◽  
Felix Piringer ◽  
María Pérez Ortega ◽  
Robert Presl ◽  
Markus Rothacher

<p>GNSS antennas are a key factor in precise GNSS positioning. With the increasing availability of low-cost dual-frequency GNSS receivers also the demands on low-cost GNSS antennas increases. Unfortunately, the electronic center of most GNSS antennas is not located in the mechanical Antenna Reference Point (ARP). As a consequence, Phase Center Corrections (PCC) have to be introduced to correct for frequency-dependent signal delays within the antenna system. The PCCs are typically in the range of several millimeters to centimeters. Thus, uncorrected phase center variations can be a significant error source in precise positioning.</p><p>For the purpose of antenna calibration, the Institute of Geodesy and Photogrammetry at ETH Zürich acquired a six-axis industrial robot of type KUKA AGILUS KR 6 R900 sixx. In an initial study, the absolute accuracy of the robot has been determined to be better than 1.5 mm (standard deviation). By introducing a set of extended Denavit-Hartenberg parameters, the absolute position accuracy of the robot is further increased to 0.3 mm over the entire workspace and 0.1 mm for a predefined sequence of robot poses, respectively. Therefore, the robot operates well below the phase noise of the GNSS measurements (typically around 1 mm) and is therefore seen as suitable for the calibration of GNSS antennas with sub-millimeter accuracy.</p><p>Besides the numerous benefits of absolute field calibration with an industrial robot, several challenges remain if it comes to low-cost GNSS antennas. The main challenges are that for each antenna a specific mounting system has to be built and that low-cost antennas are in general less shielded against multipath (compared to geodetic antennas). Besides, only little information exists about the stability of the electronic reference point and how much the electronic properties change when the antenna is mounted on different platforms (cars, drones, cubesats, etc).</p><p>To address the critical issues in low-cost GNSS antenna calibration and study the impact of the PCCs on the positioning solution, a calibration campaign has been initiated at ETH Zürich in autumn 2020. In this campaign, a set of low-cost multi-GNSS dual-frequency patch and loop antennas - suited for centimeter-positioning - has been calibrated and tested. Therefore, in the vicinity of the GNSS reference station (ETH2) the robot has been installed and a sequence of randomized robot poses has been executed in which the ARP of each antenna was defined as rotation point. The GNSS signals recorded during this sequence were processed together with the robot attitude information using the time-differencing approach defined by D. Willi (2019) using a spherical harmonics parameterization.</p><p>The PCCs obtained from the calibration campaign were stored in ANTEX files for a subsequent validation. In this presentation, we will highlight the developed calibration procedures for low-cost GNSS antennas, summarize the main results of the calibration and validation campaign, and will give the framework in which a calibration of low-cost GNSS antennas is considered beneficial.</p><p>Willi D., GNSS receiver synchronization and antenna calibration, PhD Thesis, ETH Zürich, 2019, https://www.research-collection.ethz.ch/handle/20.500.11850/308750</p>


2009 ◽  
Vol 129 (6) ◽  
pp. 733-744 ◽  
Author(s):  
Shoji Kawasaki ◽  
Yasuhiro Hayashi ◽  
Junya Matsuki ◽  
Hirotaka Kikuya ◽  
Masahide Hojo

2009 ◽  
Vol 129 (2) ◽  
pp. 324-330
Author(s):  
Hirotaka Takano ◽  
Takafumi Tomida ◽  
Yasuhiro Hayashi ◽  
Junya Matsuki

2016 ◽  
Vol 5 (10) ◽  
pp. 4920
Author(s):  
Amar M. Ali ◽  
Hussain. J. Mohammed*

A new, simple, sensitive and rapid spectrophotometric method is proposed for the determination of trace amount of Nickel (II). The method is based on the formation of a 1:2 complex with 4-(4-((2-hydroxy-6-nitrophenyl) diazenyl) -3-methyl-5-oxo-2, 5-dihydro-1H-pyrazol-1-yl) benzenesulfonic acid (2-ANASP) as a new reagent is developed. The complex has a maximum absorption at 516 nm and εmax of 1. 84 X 105 L. mol-1. cm-1. A linear correlation (0. 25 – 4. 0μg. ml-1) was found between absorbance at λmax and concentration. The accuracy and reproducibility of the determination method for various known amounts of Nickel (II) were tested. The results obtained are both precise (RSD was 1. 2 %) and accurate (relative error was 0. 787 %). The effect of diverse ions on the determination of Nickel (II) to investigate the selectivity of the method were also studied. The stability constant of the product was 0. 399 X 106 L. mol-1. The proposed method was successfully applied to the analysis of diabetes blood and normal human blood. 


Sign in / Sign up

Export Citation Format

Share Document