Retrospective review of CT brain image quality, diagnostic adequacy and radiation dose in a paediatric population imaged at a non‐paediatric tertiary hospital

2019 ◽  
Vol 63 (5) ◽  
pp. 596-601
Author(s):  
Lisa Luo‐Lan Ling ◽  
Greg Fitt ◽  
Mark Begbie ◽  
Catriona Anne Fleming ◽  
Yuliya Perchyonok
Author(s):  
Sultan Aldosari ◽  
Zhonghua Sun

Background: The aim of this study is to perform a systematic review of the feasibility and clinical application of double low-dose CT pulmonary angiography (CTPA) in the diagnosis of patients with suspected pulmonary embolism. Discussion: A total of 13 studies were found to meet selection criteria reporting both low radiation dose (70 or 80 kVp versus 100 or 120 kVp) and low contrast medium dose CTPA protocols. Lowdose CTPA resulted in radiation dose reduction from 29.6% to 87.5% in 12 studies (range: 0.4 to 23.5 mSv), while in one study, radiation dose was increased in the dual-energy CT group when compared to the standard 120 kVp group. CTPA with use of low contrast medium volume (range: 20 to 75 ml) was compared to standard CTPA (range: 50 to 101 ml) in 12 studies with reduction between 25 and 67%, while in the remaining study, low iodine concentration was used with 23% dose reduction achieved. Quantitative assessment of image quality (in terms of signal-to-noise ratio and contrast-to-noise ratio) showed that low-dose CTPA was associated with higher, lower and no change in image quality in 3, 3 and 6 studies, respectively when compared to the standard CTPA protocol. The subjective assessment indicated similar image quality in 11 studies between low-dose and standard CTPA groups, and improved image quality in 1 study with low-dose CTPA. Conclusion: This review shows that double low-dose CTPA is feasible in the diagnosis of pulmonary embolism with significant reductions in both radiation and contrast medium doses, without compromising diagnostic image quality.


2021 ◽  
Vol 182 ◽  
pp. 109380
Author(s):  
Muhammad Kabir Abdulkadir ◽  
Iliyasu Yusuf Izge ◽  
Garba Haruna Yunusa ◽  
Abacha Mohammed ◽  
Noor Diyana Osman

2020 ◽  
pp. 205141582098119
Author(s):  
Benjamin Storey ◽  
Nathan Shugg ◽  
Alison Blatt

Background: Testicular torsion is an organ-threatening surgical emergency with a limited timeframe for intervention. Objective: To identify the delays to surgical exploration of patients with an acute scrotum in a tertiary hospital to prevent adverse outcomes associated with this time critical emergency. Methods: A retrospective review of medical records for all patients who underwent scrotal exploration for acute scrotal pain in a tertiary hospital in regional New South Wales between January 2008 to December 2018 was performed. Results: Retrospective review identified 242 patients, of whom 161 had testicular torsion and 56 resultant orchidectomies. No statistically significant difference in pre-hospital delays between paediatric or adult populations was found. The average time from presentation to theatre was 4 h 36 min. Patients who were delayed > 6 h from presentation to surgical exploration had significantly increased rates of orchidectomy. Delays that significantly affected rates of orchidectomy were transfer from peripheral sites, late presentation, misdiagnosis and representation after discharge. Conclusion: The most common reason for delay was diagnostic error with the patient later re-presenting to hospital. Patient transfer from the primary hospital to a tertiary institution and subsequent delayed surgical exploration also contributed to significantly higher rates of orchidectomy. Level of Evidence: 3


Diagnostics ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 118
Author(s):  
Andreas S. Brendlin ◽  
Moritz T. Winkelmann ◽  
Phuong Linh Do ◽  
Vincent Schwarze ◽  
Felix Peisen ◽  
...  

To evaluate the effect of radiation dose reduction on image quality and diagnostic confidence in contrast-enhanced whole-body computed tomography (WBCT) staging. We randomly selected March 2016 for retrospective inclusion of 18 consecutive patients (14 female, 60 ± 15 years) with clinically indicated WBCT staging on the same 3rd generation dual-source CT. Using low-dose simulations, we created data sets with 100, 80, 60, 40, and 20% of the original radiation dose. Each set was reconstructed using filtered back projection (FBP) and Advanced Modeled Iterative Reconstruction (ADMIRE®, Siemens Healthineers, Forchheim, Germany) strength 1–5, resulting in 540 datasets total. ADMIRE 2 was the reference standard for intraindividual comparison. The effective radiation dose was calculated using commercially available software. For comparison of objective image quality, noise assessments of subcutaneous adipose tissue regions were performed automatically using the software. Three radiologists blinded to the study evaluated image quality and diagnostic confidence independently on an equidistant 5-point Likert scale (1 = poor to 5 = excellent). At 100%, the effective radiation dose in our population was 13.3 ± 9.1 mSv. At 20% radiation dose, it was possible to obtain comparably low noise levels when using ADMIRE 5 (p = 1.000, r = 0.29). We identified ADMIRE 3 at 40% radiation dose (5.3 ± 3.6 mSv) as the lowest achievable radiation dose with image quality and diagnostic confidence equal to our reference standard (p = 1.000, r > 0.4). The inter-rater agreement for this result was almost perfect (ICC ≥ 0.958, 95% CI 0.909–0.983). On a 3rd generation scanner, it is feasible to maintain good subjective image quality, diagnostic confidence, and image noise in single-energy WBCT staging at dose levels as low as 40% of the original dose (5.3 ± 3.6 mSv), when using ADMIRE 3.


2015 ◽  
Vol 204 (6) ◽  
pp. 1197-1202 ◽  
Author(s):  
Yookyung Kim ◽  
Yoon Kyung Kim ◽  
Bo Eun Lee ◽  
Seok Jeong Lee ◽  
Yon Ju Ryu ◽  
...  