Evaluation of fingertip pulse oximeters for monitoring haemoglobin oxygen saturation in arterial blood and pulse rate in isoflurane‐anaesthetised horses breathing greater than 90 percent oxygen

Author(s):  
A. M. Sage ◽  
T. D. Ambrisko ◽  
F. D. C. Martins ◽  
S. C. Dantino ◽  
S. C. J. Keating ◽  
...  
2021 ◽  
Vol 82 (4) ◽  
pp. 268-273
Author(s):  
Tamas D. Ambrisko ◽  
Stephanie C. Dantino ◽  
Stephanie C. J. Keating ◽  
Danielle E. Strahl-Heldreth ◽  
Adrianna M. Sage ◽  
...  

2020 ◽  
Vol 98 (Supplement_4) ◽  
pp. 422-422
Author(s):  
Rebecca L Moore ◽  
Cierrah J Kassetas ◽  
Leslie A LeKatz ◽  
Bryan W Neville

Abstract One hundred and twenty-six yearling angus steers (initial body weight 445.87 ± 7.13 kg) were utilized in a 2 x 2 factorial design to evaluate the impacts of bunk management and modified distillers grains plus solubles (mDGS) inclusion on feedlot performance, hydrogen sulfide concentrations and blood oxygen saturation. Treatments included bunk management strategy either control bunk management (CON; clean bunks at the time of next day’s feeding) or long bunk management (LONG; feed remaining at time of next day’s feeding), and two inclusion rates of mDGS either 25% or 50% (DM Basis). On d 0, 7, 14, 21, 28 and 35 rumen gas samples were collected via rumenocentesis, and arterial blood samples were collected on two steers from each pen. No differences (P ≥ 0.09) were observed for dry matter intake, average daily gain and gain-to-feed ratio for bunk management or mDGS inclusion. Hot carcass weight, ribeye area, marbling score and quality grade were not affected (P ≥ 0.48) by either bunk management or mDGS inclusion. Back fat was greater (P = 0.04) for CON steers compared to LONG (1.30 vs 1.12 ± 0.05cm, respectively), but was not affected (P = 0.59) by mDGS inclusion. Steers on CON had greater (P = 0.03) yield grades compared to LONG (3.21 vs 2.96 ± 0.11, respectively). Bunk management strategy did not impact hydrogen sulfide concentrations or blood oxygen saturation (P = 0.82). Hydrogen sulfide concentrations increased (P < 0.001) with increasing mDGS inclusion. Blood oxygen saturation was influenced by day of sampling (P = 0.01). Blood oxygen saturation was not affected (P = 0.07) by mDGS inclusion. The fact that ruminal hydrogen sulfide concentrations increased while blood oxygen saturation remained similar raises questions about the quantity of hydrogen sulfide and metabolic fate of excess hydrogen sulfide in the blood of ruminant animals.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Erzat Toprak ◽  
Ayça Nazlı Bulut

AbstractObjectivesOur aim was to evaluate the effect of standard surgical and N-95 respiratory mask use on maternal oxygen saturation, vital signs and result on non-stress tests in term pregnancies.MethodsIt is a prospective observational study. The study included healthy, not in labor, singleton pregnant women of 370/7–410/7 weeks who were applied to our hospital for routine obstetric control examination between March 1, 2020, and August 31, 2020. Patients were randomised by coin toss method. Oxygen saturation, systolic, and diastolic arterial blood pressure, pulse, respiratory rate, and temperature of pregnant women using surgical masks and respiratory masks were measured before and after the non-stress test. The tolerance of the masks was also evaluated. Student’s t-test was used for variables showing parametric distribution and the Mann Whitney U-test was used for non-parametric tests. The categorical variables between the groups was analyzed by using the Chi square test or Fisher Exact test. The statistical significance level was taken as p<0.05 in all tests.ResultsA total of 297 pregnant women using masks were included in the study. The effect of mask type on oxygen saturation before and after the non-stress test was found to be significant (97.1±1.8 corresponds to 95.3±2.6 for the surgical mask, p=0.0001; 97.8±1.7 corresponds to 93.7±2.0 for the respiratory mask, p=0.0001). Mask tolerance of patients using respiratory masks was significantly higher than those using surgical masks (mean 8, 1–10, p=0.0001).ConclusionsSurgical mask and respiratory mask usage decreased significantly in oxygen saturation in term pregnancies.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shinshu Katayama ◽  
Jun Shima ◽  
Ken Tonai ◽  
Kansuke Koyama ◽  
Shin Nunomiya

AbstractRecently, maintaining a certain oxygen saturation measured by pulse oximetry (SpO2) range in mechanically ventilated patients was recommended; attaching the INTELLiVENT-ASV to ventilators might be beneficial. We evaluated the SpO2 measurement accuracy of a Nihon Kohden and a Masimo monitor compared to actual arterial oxygen saturation (SaO2). SpO2 was simultaneously measured by a Nihon Kohden and Masimo monitor in patients consecutively admitted to a general intensive care unit and mechanically ventilated. Bland–Altman plots were used to compare measured SpO2 with actual SaO2. One hundred mechanically ventilated patients and 1497 arterial blood gas results were reviewed. Mean SaO2 values, Nihon Kohden SpO2 measurements, and Masimo SpO2 measurements were 95.7%, 96.4%, and 96.9%, respectively. The Nihon Kohden SpO2 measurements were less biased than Masimo measurements; their precision was not significantly different. Nihon Kohden and Masimo SpO2 measurements were not significantly different in the “SaO2 < 94%” group (P = 0.083). In the “94% ≤ SaO2 < 98%” and “SaO2 ≥ 98%” groups, there were significant differences between the Nihon Kohden and Masimo SpO2 measurements (P < 0.0001; P = 0.006; respectively). Therefore, when using automatically controlling oxygenation with INTELLiVENT-ASV in mechanically ventilated patients, the Nihon Kohden SpO2 sensor is preferable.Trial registration UMIN000027671. Registered 7 June 2017.


Biofeedback ◽  
2012 ◽  
Vol 40 (4) ◽  
pp. 137-141 ◽  
Author(s):  
Christopher Gilbert

Small pulse oximeters have become widely available and can be useful for noninvasive monitoring of blood oxygen saturation by nonmedical personnel. When training control of breathing, an oximeter helps to reassure clients who hyperventilate that their oxygenation is adequate, offsetting their perception that they are not getting enough air. Low saturation may indicate a medical condition that impairs oxygen absorption. In that case, hyperventilation is a biological compensation that should not be tampered with.


1944 ◽  
Vol 79 (1) ◽  
pp. 9-22 ◽  
Author(s):  
Frank L. Engel ◽  
Helen C. Harrison ◽  
C. N. H. Long

1. In a series of rats subjected to hemorrhage and shock a high negative correlation was found between the portal and peripheral venous oxygen saturations and the arterial blood pressure on the one hand, and the blood amino nitrogen levels on the other, and a high positive correlation between the portal and the peripheral oxygen saturations and between each of these and the blood pressure. 2. In five cats subjected to hemorrhage and shock the rise in plasma amino nitrogen and the fall in peripheral and portal venous oxygen saturations were confirmed. Further it was shown that the hepatic vein oxygen saturation falls early in shock while the arterial oxygen saturation showed no alteration except terminally, when it may fall also. 3. Ligation of the hepatic artery in rats did not affect the liver's ability to deaminate amino acids. Hemorrhage in a series of hepatic artery ligated rats did not produce any greater rise in the blood amino nitrogen than a similar hemorrhage in normal rats. The hepatic artery probably cannot compensate to any degree for the decrease in portal blood flow in shock. 4. An operation was devised whereby the viscera and portal circulation of the rat were eliminated and the liver maintained only on its arterial circulation. The ability of such a liver to metabolize amino acids was found to be less than either the normal or the hepatic artery ligated liver and to have very little reserve. 5. On complete occlusion of the circulation to the rat liver this organ was found to resist anoxia up to 45 minutes. With further anoxia irreversible damage to this organ's ability to handle amino acids occurred. 6. It is concluded that the blood amino nitrogen rise during shock results from an increased breakdown of protein in the peripheral tissues, the products of which accumulate either because they do not circulate through the liver at a sufficiently rapid rate or because with continued anoxia intrinsic damage may occur to the hepatic parenchyma so that it cannot dispose of amino acids.


2021 ◽  
Vol 32 (8) ◽  
pp. 312-316
Author(s):  
Paul Silverston

The pandemic has led to an increase in the use of pulse oximetry to assess and manage patients with COVID-19 disease. Paul Silverston explains the principles of pulse oximetry and the factors that can affect the reliability and accuracy of readings Pulse oximetry is performed to detect and quantify the degree of hypoxia in patients with respiratory symptoms and illnesses, including patients with COVID-19 disease. Pulse oximeters are non-invasive, simple to use and inexpensive, but it is important to know how to interpret the readings in the context of the patient's symptoms and the other clinical findings. In COVID-19 disease, very small differences in the oxygen saturation reading result in significant differences in the way that the patient is managed, so it is important to be aware of the factors that can affect these readings. It is also important to appreciate that a low reading in a patient with suspected or confirmed COVID-19 disease may be the result of another disease process.


Sign in / Sign up

Export Citation Format

Share Document