The HemoCueR for point-of-care hemoglobin measurement and packed cell volume estimation in cats

2005 ◽  
Vol 15 (1) ◽  
pp. 22-25 ◽  
Author(s):  
Lysa P. Posner ◽  
Hollis N. Erb ◽  
Robin D. Gleed
2008 ◽  
Vol 104 (11/12) ◽  
Author(s):  
A.J. Groenewald ◽  
H. Pieters

A small portable eletronic device, named a blood electrometer (BEM), was developed to measure packed cell volume, which can be related to haematocrit (Hct). The electronic circuitry is simple and constructed from standard components. Being battery powered, the device is suitable for bedside or field use ('point-of-care-testing') without specialized training. The effects of temperature, anticoagulants, lipid content, electrode type and different BEM electronic circuits on measurement accuracy were evaluated. A method for calibrating the instrument with a sodium chloride calibrator was also devised and evaluated for measurement accuracy. The response of the BEM to Hct is non-linear; a binomial regression function was used to fit the non-linear response to provide accurate Hct values from BEM readings over a wide range of measurements. The BEM response curve is sensitive to the anticoagulant type used, but specific binomial functions reduce error to between –3.1% and +3.3% Hct units. Lipids do not significantly affect BEM readings, even at high concentrations of 9.8 mmol/l. We conclude that the BEM can be relied on for acceptably accurate Hct measurements under a variety of conditions, and can be used for the indirect determination of packed cell volume.


2005 ◽  
Vol 41 (3) ◽  
pp. 179-184 ◽  
Author(s):  
Jennifer L. Strasser ◽  
Eleanor C. Hawkins

Epistaxis was retrospectively evaluated in 35 dogs. Systemic disease was diagnosed in seven dogs and intranasal disease in 29. Nineteen dogs with intranasal disease had neoplasia. Dogs with neoplasia were older (mean 10.0 years) than dogs with nonneoplastic intranasal disease (mean 5.6 years). Signs persisting for >1 month occurred more often in dogs with intranasal than systemic disease. Unilateral epistaxis did not distinguish intranasal from systemic disease. Only dogs with intranasal disease had facial deformity, decreased airflow, or regional sub-mandibular lymphadenopathy. Dogs with systemic disease had a lower packed cell volume (mean 31.8%) than dogs with intranasal disease (mean 42.7%).


2021 ◽  
Author(s):  
Jenifer Gómez-Pastora ◽  
James Kim ◽  
Mitchell Weigand ◽  
Andre F. Palmer ◽  
Mark Yazer ◽  
...  

Abstract Anemia and iron deficiency continue to be the most prevalent nutritional disorders in the world, affecting billions of people in both developed and developing countries. The initial diagnosis of anemia is typically based on several markers, including red blood cell (RBC) count, hematocrit and total hemoglobin. Using modern hematology analyzers, erythrocyte parameters such as mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), etc. are also being used. However, most of these commercially available analyzers pose several disadvantages: they are expensive instruments that require significant bench space and are heavy enough to limit their use to a specific lab and leading to a delay in results, making them less practical as a point-of-care instrument that can be used for swift clinical evaluation. Thus, there is a need for a portable and economical hematology analyzer that can be used at the point of need. In this work, we evaluated the performance of a system referred to as the cell tracking velocimetry (CTV) to measure several hematological parameters from fresh human blood obtained from healthy donors. Our system, based on the paramagnetic behavior that methemoglobin containing RBCs experience when suspended in water after applying a magnetic field, uses a combination of magnets and microfluidics and has the ability to track the movement of thousands of red cells in a short period of time. This allows us to measure not only traditional RBC indices but also novel parameters that are only available for analyzers that assess erythrocytes on a cell by cell basis. As such, we report, for the first time, the use of our CTV as a hematology analyzer that is able to measure red cell volume or MCV, red cell hemoglobin mass or MCH, hemoglobin concentration (MCHC), red cell distribution width (RDW) and the percentage of hypochromic cells, which is an indicator of insufficient marrow iron supply that reflects recent iron reduction. Our initial results indicate that most of the parameters measured with CTV are within the normal range for healthy adults. Only the parameters related to the red cell volume (primarily MCV and RDW) were outside the normal range. We observed significant discrepancies between the MCV measured by our technology (and also by an automated cell counter) and the manual MCV measured through the hematocrit obtained by packed cell volume method, which are attributed to the artifacts of plasma trapping and cell shrinkage. While there may be limitations for measuring MCV, this device offers a novel point of care instrument to provide rapid RBC parameters such as iron stores that are otherwise not rapidly available to the clinician. Thus, our CTV is a promising technology with the potential to be employed as an accurate, economical, portable and fast hematology analyzer after applying instrument-specific reference ranges or correction factors.


1970 ◽  
Vol 19 (4) ◽  
pp. 3038-3044
Author(s):  
Helen Chioma Okoye ◽  
Chilota Chibuife Efobi ◽  
Josephat Maduabuchi Chinawa ◽  
Odutola Israel Odetunde ◽  
Awoere Tamunosiki Chinawa ◽  
...  

Background: Maternal factors are determinants of birth outcome which includes birth weight, haematological indices and mode of delivery of their babies.Objectives: To determine the impact of parity and gestational age of hypertensive mothers on some neonatal variables.Methods: A hospital based cross-sectional study of measurement of neonatal variables (birth weight, red blood cells and mode of delivery) among hypertensive mothers and their controls was conducted over a period of six months. Data were analyzed using the Statistical Package for Social Sciences program (SPSS), version 20.Results: There were statistically significant differences in means between the neonates of the hypertensive group and non-hypertensive group for maternal age (t =1.61, p = 0.002), baby weight (t =2.87, p < 0.001), haemoglobin (Hb) (t =4.65, p = 0.010) and packed cell volume (PCV) (t =4.75, p = 0.009), but none for gravidity (t =1.95, p = 0.927)For all subjects, there was poor correlation between gestational age and variables; birth weight , haemoglobin (Hb), packed cell volume (PCV), nucleated red blood cell (nRBC) and parity. Likewise, parity poorly correlated with variables; age, birth weight, Hb, PCV, and nRBC. There was a statistically significant association between mode of delivery and hypertension (χ2 =53.082, p <0.001) but none with having a family history of hypertension (χ2 =1.13, p = 0.287).Conclusion: Parity and gestational age of mothers with hypertension have no impact on birth weight and red cells when compared with their non-hypertensive counterparts. However, mothers of babies delivered by elective and emergency caesarean section were about 2-3 times more likely to be hypertensive than those that delivered through spontaneous vertex delivery.Keywords: Hypertension; neonate; gestational age; parity.


2018 ◽  
pp. 457-458
Author(s):  
Craig R Breheny ◽  
Jorge Perez-Accino Salgado ◽  
Nicholas X Bommer ◽  
Ian Handel ◽  
Adam G Gow

Author(s):  
I. Iwanegbe ◽  
M. Suleiman ◽  
A. Jimah

Aims: To investigate the effect of food blends (plantain, soybean and ginger) on the blood glucose, lipid profile and haematological indices on streptozotocin induced diabetic rats. Methodology: A total of 35 rats of mean body weight 219.07 g separated into7 groups (5 per group) where induced by a single intraperitoneal (I.P) injection of streptozotocin (0.1 g dissolved in 5 ml of freshly prepared sodium citrate buffer 0.1 M, pH 4.5) at a dose of 40 mg/kg body weight after fasting for 12 hours and fed with flours/blends. The flours were produced from plant materials for different treatments/blends (blend A=100% unripe plantain, B=80% unripe plantain, 14% soybean, 6% ginger, C=70% unripe plantain, 26% soybean, 4% ginger, D= 60% unripe plantain, 38% soybean, 2% ginger, E= 50% unripe plantain, 50% soybean) and the phytochemicals and minerals content were determined. Blood glucose was determined at 5 days interval for 25 days. Diabetes was confirmed in rats with blood glucose concentrations >200 mg/dl. After 25 days rats were anaesthetized with chloroform vapour and blood samples collected by cardiac puncture for haematology and lipid profile determination. Results: The results showed that unripe plantain, soya beans and ginger in adequate proportion(C=70% unripe plantain, 26% soybean, 4% ginger or D= 60% unripe plantain, 38% soybean, 2% ginger) could help to reduce blood glucose, improve haematological parameters and lipid profile. Significant reduction was observed in the blood glucose level of rats fed blends C and D from 286 to 85 mg/dl and 307 to 90 mg/dl respectively at the end of experiment. These results also demonstrated that the inclusion of ginger at 6% causes rise in blood glucose level. Total cholesterol (TC) increased in all the blends. However, the lowest concentration of TC was observed in blends C and D. The highest packed cell volume (60%) and Haemoglobin (20 g/dl) level observed in rats fed blend C was significantly higher than the normal control fed conventional feeds. The increase in packed cell volume (PCV) (50%) and Hb (17 g/dl) in diabetic rats demonstrated that the formulated blend C was able to raise PCV and Hb above 50% and 17 g/dl (Normal control NC) respectively. Significant increase (P<0.05) in low density lipoprotein cholesterol (LDLc) was also observed in all the blends with blend C having the least (4.0 mg/dl) close to NC (2.0 mg/dl). Conclusion: From the results it is evident that blend C will manage and improve the health status of diabetic patients.


2007 ◽  
Vol 4 (1) ◽  
pp. 77-82
Author(s):  
Baghdad Science Journal

A dose of ten grams of the roots and leaves of Nettle (Urtica dioica) dissolved in (200)ml of boiled water then covered for (10)min. was given to a sample of (15) patients attending to the herbal department of ministry of health complaining of malnutrition and low Hb(hemoglobin) concentration and PCV(packed cell volume) levels with absence of any other predisposing factors disease inorder to find the effects of these roots and leaves on Hb and PCV levels for different periods of time in relation to age and sex variations . The study have shown that this mixture has a high significant effect (p