Prevalence of Legionella pneumophila serogroup 1 in water distribution systems in İzmir province of Turkey

Apmis ◽  
2005 ◽  
Vol 113 (10) ◽  
pp. 664-669 ◽  
Author(s):  
ATAÇ UZEL ◽  
FÜSUN UÇAR ◽  
E. ESİN HAMEŞ-KOCABAŞ
Author(s):  
Luna Girolamini ◽  
Silvano Salaris ◽  
Jessica Lizzadro ◽  
Marta Mazzotta ◽  
Maria Rosaria Pascale ◽  
...  

In this study, we aimed to associate the molecular typing of Legionella isolates with a culture technique during routine Legionella hospital environmental surveillance in hot water distribution systems (HWDSs) to develop a risk map able to be used to prevent nosocomial infections and formulate appropriate preventive measures. Hot water samples were cultured according to ISO 11731:2017. The isolates were serotyped using an agglutination test and genotyped by sequence-based typing (SBT) for Legionella pneumophila or macrophage infectivity potentiator (mip) gene sequencing for non-pneumophila Legionella species. The isolates’ relationship was phylogenetically analyzed. The Legionella distribution and level of contamination were studied in relation to temperature and disinfectant residues. The culture technique detected 62.21% of Legionella positive samples, characterized by L. pneumophila serogroup 1, Legionella non-pneumophila, or both simultaneously. The SBT assigned two sequence types (STs): ST1, the most prevalent in Italy, and ST104, which had never been isolated before. The mip gene sequencing detected L. anisa and L. rubrilucens. The phylogenetic analysis showed distinct clusters for each species. The distribution of Legionella isolates showed significant differences between buildings, with a negative correlation between the measured level of contamination, disinfectant, and temperature. The Legionella molecular approach introduced in HWDSs environmental surveillance permits (i) a risk map to be outlined that can help formulate appropriate disinfection strategies and (ii) rapid epidemiological investigations to quickly identify the source of Legionella infections.


2019 ◽  
Vol 163 ◽  
pp. 7-16
Author(s):  
Motasem N. Saidan ◽  
Ahlam I. Abdalla ◽  
Nivin Al Alami ◽  
Hanan Al-Naimat

Water ◽  
2021 ◽  
Vol 13 (16) ◽  
pp. 2304
Author(s):  
Giovanna Deiana ◽  
Antonella Arghittu ◽  
Marco Dettori ◽  
Maria Dolores Masia ◽  
Maria Grazia Deriu ◽  
...  

The occurrence of Legionella spp. in the water distribution systems of large hospitals and other healthcare facilities is considered particularly dangerous, due to the critical nature of the hospitalized patients. The aim of this study is to present a pluri-annual environmental surveillance in a large university hospital assessing the prevalence of Legionella spp. and underlining its variability over the years. The samples of water were collected in accordance with the Italian National Guidelines and the sampling sites considered in this study were selected favoring wards with very high-risk patients and with patients at increased risk. The laboratory analyzed a total of 305 water samples deriving from 24 different sampling points. Legionella spp. were detected in 39.4% of samples, the majority of which were contaminated by Legionella pneumophila serogroups 2–14 (68.7%). Statistically significant differences were found among different seasons with a linear trend in positive proportion from summer to spring. Several experimental interventions to prevent and reduce Legionella colonization were attempted, but there is no a definitive method for the complete eradication of this microorganism. The permanent monitoring of hospital water distribution systems is fundamental to preventing the potential risk of nosocomial Legionellosis and to implementing procedures to minimize the risk of Legionella spp. colonization.


2015 ◽  
Vol 71 ◽  
pp. 244-256 ◽  
Author(s):  
Emilie Bédard ◽  
Stéphanie Fey ◽  
Dominique Charron ◽  
Cindy Lalancette ◽  
Philippe Cantin ◽  
...  

2015 ◽  
Vol 22 (2) ◽  
pp. 195-201 ◽  
Author(s):  
Agnieszka Sikora ◽  
Małgorzata Wójtowicz-Bobin ◽  
Maria Kozioł-Montewka ◽  
Agnieszka Magryś ◽  
Iwona Gładysz

Author(s):  
Abdelwahid Assaidi ◽  
Mostafa Ellouali ◽  
Hassan Latrache ◽  
Hafida Zahir ◽  
El Mostafa Mliji

Background and Objectives: Legionnaires’ disease continues to be a public health concern. Colonized water distribution systems are often implicated in Legionella transmission, despite the use of various disinfection strategies, the bacterium is capable to persist and survive in water systems. The aim of this study was to investigate the persistence of Legionella pneumophila to sodium chloride over time at different temperatures and analysing the role of biofilms in the survival of this bacteria. Materials and Methods: L. pneumophila serogroup 1 and L. pneumophila serogroup 2-15 were used to study the effect of sodium chloride on planktonic and sessile cells. The tested concentrations were: 0.5%, 1%, 2%, 3%, 4%, 6% and 8% (W/V) NaCl. Biofilms were grown on 24-well microplates. Results: At 20°C, L. pneumophila planktonic cells were able to survive in sodium chloride concentrations up to 2%. How- ever, at 37°C, a sodium chloride concentration over 1.5%, reduced systematically the numbers of bacterial cells. Biofilms were grown for 20 days in the absence and presence of sodium chloride. The results show that bacterial strains were able to survive and regrow after the sodium chloride shock (2-3%). Moreover, it seems that this effect is less expressed with the age of the biofilm; old biofilms were more persistent than the young ones. Conclusion: Results from this study demonstrate that the sodium chloride disinfection strategy was effective on Legionella pneumophila planktonic cells but not on biofilms, which demonstrate the role of biofilms in the persistence and recoloniza- tion of L. pneumophila in water distribution systems.


2007 ◽  
Vol 73 (9) ◽  
pp. 2854-2859 ◽  
Author(s):  
Markku J. Lehtola ◽  
Eila Torvinen ◽  
Jaana Kusnetsov ◽  
Tarja Pitkänen ◽  
Leena Maunula ◽  
...  

ABSTRACT Most of the bacteria in drinking water distribution systems are associated with biofilms. In biofilms, their nutrient supply is better than in water, and biofilms can provide shelter against disinfection. We used a Propella biofilm reactor for studying the survival of Mycobacterium avium, Legionella pneumophila, Escherichia coli, and canine calicivirus (CaCV) (as a surrogate for human norovirus) in drinking water biofilms grown under high-shear turbulent-flow conditions. The numbers of M. avium and L. pneumophila were analyzed with both culture methods and with peptide nucleic acid fluorescence in situ hybridization (FISH) methods. Even though the numbers of pathogens in biofilms decreased during the experiments, M. avium and L. pneumophila survived in biofilms for more than 2 to 4 weeks in culturable forms. CaCV was detectable with a reverse transcription-PCR method in biofilms for more than 3 weeks. E. coli was detectable by culture for only 4 days in biofilms and 8 days in water, suggesting that it is a poor indicator of the presence of certain waterborne pathogens. With L. pneumophila and M. avium, culture methods underestimated the numbers of bacteria present compared to the FISH results. This study clearly proved that pathogenic bacteria entering water distribution systems can survive in biofilms for at least several weeks, even under conditions of high-shear turbulent flow, and may be a risk to water consumers. Also, considering the low number of virus particles needed to result in an infection, their extended survival in biofilms must be taken into account as a risk for the consumer.


2019 ◽  
Vol 73 ◽  
pp. 47-52
Author(s):  
Iwona Gładysz ◽  
Maria Kozioł-Montewka ◽  
Agnieszka Sikora ◽  
Małgorzata Wójtowicz-Bobin ◽  
Jan Karczewski

Background: Microbiological threat from Legionella spp. is associated with the current widespread use of air-condition systems and frequent colonization of hot water distribution systems in public facilities (hospitals, hotels, nursing homes). This poses a particularly high risk in hospitalized patients, as many of them are immunocompromised. More than 50 species and 72 serogroups of Legionella spp. have been described thus far, including more than 20 species being pathogenic to humans. Material/Methods: Microbiological threat posed by Legionella spp. was assessed based on a retrospective analysis of microbiological quality of water from hot water distribution systems in Polish hospitals, determined in 2009-2013 at certified laboratories of the Sanitary-Epidemiological Surveillance. The results were kindly provided by the hospitals’ administration upon request, for which the authors would like to express their deepest gratitude. The study material included samples of hot water from internal distribution systems in 379 Polish hospitals, collected by the State Sanitary Inspectorate. Results: Based on the results of microbiological analyses, we were able to estimate Legionella spp. colonization rates in hospital water distribution systems and to assess the activities undertaken by the State Sanitary Inspectorate to reduce excessive bacterial counts in this reservoir. Microbiological analyses conducted in 2009-2013, i.e. after implementing a statutory obligation to monitor Legionella spp. in hospital hot water distribution systems, showed elevated bacterial counts in 3.92% to 12.7% of the samples. These findings justify further microbiological monitoring of hospital water distribution systems. Discussion: The prevalence of the most pathogenic serotype SG1 in hot water distribution systems of Polish hospitals is relatively low compared to other European countries. To maintain this favorable status, hospital water systems should be monitored not only for the presence of Legionella pneumophila, but also for the prevalence of serogroup 1 L. pneumophila.


2020 ◽  
Author(s):  
Joseph Saoud ◽  
Thangadurai Mani ◽  
Sébastien P. Faucher

ABSTRACTLegionella pneumophila (Lp) is an inhabitant of natural and man-made water systems where it replicates within amoebae and ciliates and survives within biofilms. When Lp-contaminated aerosols are breathed in, Lp will enter the lungs and infect human alveolar macrophages, causing a severe pneumonia known as Legionnaires Disease. Lp is often found in hot water distribution systems (HWDS), which are linked to nosocomial outbreaks. Heat treatment is used to disinfect HWDS and reduce the concentration of Lp. However, Lp is often able to recolonize these water systems, indicating an efficient heat-shock response. Tail-specific proteases (Tsp) are typically periplasmic proteases implicated in degrading aberrant proteins in the periplasm and important for surviving thermal stress. In this paper, we show that Tsp, encoded by the lpg0499 gene in Lp Philadelphia-1, is important for surviving thermal stress in water and for optimal infection of amoeba when a shift in temperature occurs during intracellular growth. Tsp is expressed in the post-exponential phase but repressed in the exponential phase. The cis-encoded small regulatory RNA Lpr17 shows opposite expression, suggesting that it represses translation of tsp. In addition, tsp is regulated by CpxR, a major regulator in Lp, in a Lpr17-independent manner. Deletion of CpxR also reduced the ability of Lp to survive heat shock. In conclusion, this study shows that Tsp is an important factor for the survival and growth of Lp in water systems.IMPORTANCELegionella pneumophila (Lp) is a major cause of nosocomial and community-acquired pneumonia. Lp is found in water systems including hot water distribution systems. Heat treatment is a method of disinfection often used to limit Lp’s presence in such systems; however, the benefit is usually short term as Lp is able to quickly recolonize these systems. Presumably, Lp respond efficiently to thermal stress, but so far not much is known about the genes involved. In this paper, we show that the Tail-specific protease (Tsp) and the two-component system CpxRA are required for resistance to thermal stress, when Lp is free in water and when it is inside host cells. Our study identifies critical systems for the survival of Lp in its natural environment under thermal stress.


Sign in / Sign up

Export Citation Format

Share Document