Poor Glycemic Control is a Significant Predictor of Cardiovascular Events in Chronic Hemodialysis Patients With Diabetes

2009 ◽  
Vol 13 (4) ◽  
pp. 358-365 ◽  
Author(s):  
Yoshihiro Tsujimoto ◽  
Eiji Ishimura ◽  
Hideki Tahara ◽  
Ryuusuke Kakiya ◽  
Hidenori Koyama ◽  
...  
2017 ◽  
Vol 47 (1) ◽  
pp. 21-29 ◽  
Author(s):  
Maria Divani ◽  
Panagiotis I. Georgianos ◽  
Triantafyllos Didangelos ◽  
Fotios Iliadis ◽  
Areti Makedou ◽  
...  

Background: Glycated hemoglobin A1c (HbA1c) among diabetic hemodialysis patients continues to be the standard of care, although its limitations are well recognized. This study evaluated glycated albumin (GA) and glycated serum protein (GSP) as alternatives to HbA1c in detecting glycemic control among diabetic hemodialysis patients using continuous-glucose-monitoring (CGM)-derived glucose as reference standard. Methods: A CGM system (iPRO) was applied for 7 days in 37 diabetic hemodialysis patients to determine glycemic control. The accuracy of GA and GSP versus HbA1c in detecting a 7-day average glucose ≥184 mg/dL was evaluated via receiver-operating-characteristic (ROC) analysis. Results: CGM-derived glucose exhibited strong correlation (r = 0.970, p < 0.001) and acceptable agreement with corresponding capillary glucose measurements obtained by the patients themselves in 1,169 time-points over the 7-day-long CGM. The area under ROC curve (AUC) for GA, GSP, and HbA1c to detect poor glycemic control was 0.976 (0.862–1.000), 0.682 (0.502–0.862), and 0.776 (0.629–0.923) respectively. GA levels >20.3% had 90.9% sensitivity and 96.1% specificity in detecting a 7-day average glucose ≥184 mg/dL. The AUC for GA was significantly higher than the AUC for GSP (difference between areas: 0.294, p < 0.001) and the AUC for HbA1c (difference between areas: 0.199, p < 0.01). Conclusion: Among diabetic hemodialysis patients, GA is a stronger indicator of poor glycemic control assessed with 7-day-long CGM when compared to GSP and HbA1c.


Diabetes ◽  
2018 ◽  
Vol 67 (Supplement 1) ◽  
pp. 1588-P
Author(s):  
JINNIE J. RHEE ◽  
YUANCHAO ZHENG ◽  
MARIA MONTEZ-RATH ◽  
WOLFGANG WINKELMAYER

2016 ◽  
Vol 42 (1) ◽  
pp. 77-82 ◽  
Author(s):  
Faruk Turgut ◽  
Sana Sungur ◽  
Ramazan Okur ◽  
Mustafa Yaprak ◽  
Muge Ozsan ◽  
...  

Background: Bisphenol A (BPA) has been implicated as an ‘endocrine disruptor'. We aimed at exploring the association between serum BPA levels and patient characteristics, particularly the presence of diabetes mellitus, and laboratory parameters in hemodialysis patients. Methods: This study included 47 chronic hemodialysis patients. Patient characteristics were recorded. Blood was drawn before and after hemodialysis session. Serum BPA levels were measured by the high-performance-liquid-chromatography and laboratory parameters were measured by using standard methods. Results: In hemodialysis patients, postdialysis serum BPA levels were significantly higher than predialysis after a single hemodialysis session (5.57 ± 1.2 vs. 4.06 ± 0.73, p < 0.0001). Predialysis serum BPA levels were significantly higher in patients with diabetes than non-diabetics (4.4 ± 0.6 vs. 3.9 ± 0.7, p = 0.025). No association was found between serum BPA levels and patient characteristics, and particularly laboratory parameters. Conclusion: Serum BPA levels were rising significantly after a single dialysis session. Diabetic hemodialysis patients had higher predialysis serum BPA levels.


2020 ◽  
Vol 5 (7) ◽  
pp. 1014-1025 ◽  
Author(s):  
Jinnie J. Rhee ◽  
Yuanchao Zheng ◽  
Sai Liu ◽  
Maria E. Montez-Rath ◽  
Richard J. Hamill ◽  
...  

Diabetes ◽  
2012 ◽  
Vol 61 (3) ◽  
pp. 708-715 ◽  
Author(s):  
J. Ricks ◽  
M. Z. Molnar ◽  
C. P. Kovesdy ◽  
A. Shah ◽  
A. R. Nissenson ◽  
...  

Circulation ◽  
2009 ◽  
Vol 120 (24) ◽  
pp. 2421-2428 ◽  
Author(s):  
Christiane Drechsler ◽  
Vera Krane ◽  
Eberhard Ritz ◽  
Winfried März ◽  
Christoph Wanner

PLoS ONE ◽  
2017 ◽  
Vol 12 (5) ◽  
pp. e0176135 ◽  
Author(s):  
Kerry A. McBrien ◽  
Christopher Naugler ◽  
Noah Ivers ◽  
Robert G. Weaver ◽  
David Campbell ◽  
...  

Blood ◽  
2006 ◽  
Vol 108 (11) ◽  
pp. 274-274
Author(s):  
Marc Carrier ◽  
Greg A. Knoll ◽  
Dean Fergusson ◽  
Steven Doucette ◽  
Michael J. Kovacs ◽  
...  

Abstract Background: Heparin-induced thrombocytopenia is a serious complication of heparin therapy that can lead to thromboembolism, cardiovascular events or death. Patients with this disorder develop antibodies to the platelet factor 4-heparin (PF4-H) complex. Hemodialysis patients are repeatedly exposed to heparin and are at risk for developing PF4-H antibodies. The clinical impact of asymptomatic PF4-H antibodies in patients on chronic hemodialysis is not known. Objective: To determine the association between asymptomatic PF4-H antibodies and mortality in a cohort of chronic hemodialysis patients repeatedly exposed to heparin. Methods: Pre-dialysis blood samples were drawn from 419 asymptomatic patients. All patients received unfractionated heparin (Baxter) while on dialysis. All samples were screened for PF4-H antibodies using an ELISA assay (GTI PF4 Enhanced, GTI Diagnostics). All positive and indeterminate samples were then tested using an IgG-specific PF4-H ELISA assay and a platelet serotonin-release assay. Participants were then followed up prospectively for thromboembolic events, cardiovascular events, or death. Results: During a median follow-up of 2.5 years there were 129 deaths. After controlling for important potential confounding variables, the relative risk of death was 2.92 (95% CI: 1.18-7.25; P= 0.02) in patients with IgG-specific PF4-H antibodies and 4.08 (95% CI: 1.26–13.2; P= 0.02) in patients with IgG-specific antibodies and an indeterminate serotonin-release assay. Conclusions: PF4-H antibody formation is associated with increased all-cause mortality in patients on chronic hemodialysis. Further investigation is needed to determine if anticoagulation with alternative agents would improve survival in this population.


Sign in / Sign up

Export Citation Format

Share Document