dialysis session
Recently Published Documents


TOTAL DOCUMENTS

252
(FIVE YEARS 120)

H-INDEX

16
(FIVE YEARS 4)

Author(s):  
Francisco Caiza-Zambrano ◽  
Carolina Mora Palacio ◽  
Silvia Garbugino ◽  
Fabio Maximiliano Gonzalez ◽  
Marta Bala Biolcati ◽  
...  

Central venous disease (CVD) is a serious complication in hemodialysis patients. Neurological manifestations are rare. We describe a female with end-stage renal disease with throbbing headache accompanied by paresthesia, weakness, and abnormal posture of her right hand during dialysis sessions. Motor symptoms completely resolved after each dialysis session, although the headaches persisted for several hours. No neurological deficit was evidenced on physical examination. Digital subtraction angiography identified an incomplete thrombosis of the left brachiocephalic vein with retrograde flow in the internal jugular vein, sigmoid sinus, and transverse sinus on the left side. This case illustrates that cerebral venous congestion due to CVD can produce neurological symptoms. Furthermore, we systematically review the literature to identify the characteristics of the cases described so far. This allows clinicians to know the entity and have a high index of suspicion in a hemodialysis patient who develops neurological symptoms.


Author(s):  
Muhammad Abrar ◽  
Mazhar Nadeem ◽  
Sunila Fatima

Introduction: Chronic kidney disease (CKD) is a major public health problem worldwide, and its main consequences include loss of renal function leading to end-stage renal disease (ESRD), increased risk of cardiovascular disease (CVD), significant increase in morbidity and mortality, and a decrease in health-related quality of life. Aims and Objectives: The basic aim of the study is to analyze the oxidative stress and total antioxidant capacity as a biomarker of cardiovascular risk in those children who are on regular hemodialysis. Materials and Methods: This cross sectional study was conducted at DHQ hospital, Faisalabad during July 2020 to January 2021. The data were collected from the age of less than 18 years children of both sexes. There were 50 children who was selected for this study. At the time of the study, all the patients were on regular three HD sessions per week. In HD patients, venous blood samples were drawn immediately before and after hemodialysis session. Baseline laboratory investigations were carried out for all patients and controls including complete blood count, serum urea and creatinine, arterial pH, arterial blood gases and infection screening, which included blood and urinary cultures by standard methods.  Results: The data were collected from 50 dialysis patients. The mean age of this study is 15years. We collected all the demographic data of patients. The mean value of Urea is 64.34±2.44 mg/dl). At before-dialysis session, duration of disease positively correlated with TPX (r = 0.969, P <0.001), but, negatively correlated with TAC (r = −0.469, P <0.002). At after-dialysis session, HIF-1α negatively correlated with each of TPX (r = −0.529, P <0.001) and OSI (r = −0.459, P <0.003); while, OSI positively correlated with TPX (r = 0.944, P <0.001). Conclusion: It is concluded that HD patients, the clinical and prognostic significance of oxidative status associated with cardiovascular risk factors is very different from the general population. Although a direct causality cannot be inferred from such kind of correlative investigations.


2021 ◽  
Vol 10 (24) ◽  
pp. 5729
Author(s):  
Anna Gouin ◽  
Pierre Tailpied ◽  
Olivier Marion ◽  
Laurence Lavayssiere ◽  
Chloé Medrano ◽  
...  

Intradialytic hypotension can lead to superimposed organ hypoperfusion and ultimately worsens long-term kidney outcomes in critically ill patients requiring kidney replacement therapy. Acetate-free biofiltration (AFB), an alternative technique to bicarbonate-based hemodialysis (B-IHD) that does not require dialysate acidification, may improve hemodynamic and metabolic tolerance of dialysis. In this study, we included 49 mechanically ventilated patients requiring 4 h dialysis (AFB sessions n = 66; B-IHD sessions n = 62). Whereas more AFB sessions were performed in patients at risk of hemodynamic intolerance, episodes of intradialytic hypotension were significantly less frequent during AFB compared to B-IHD, whatever the classification used (decrease in mean blood pressure ≥ 10 mmHg; systolic blood pressure decrease >20 mmHg or absolute value below 95 mmHg) and after adjustment on the use of vasoactive agent. Diastolic blood pressure readily increased throughout the dialysis session. The use of a bicarbonate zero dialysate allowed the removal of 113 ± 25 mL/min of CO2 by the hemofilter. After bicarbonate reinjection, the global CO2 load induced by AFB was +25 ± 6 compared to +80 ± 12 mL/min with B-IHD (p = 0.0002). Thus, notwithstanding the non-controlled design of this study, hemodynamic tolerance of AFB appears superior to B-IHD in mechanically ventilated patients. Its use as a platform for CO2 removal also warrants further research.


2021 ◽  
pp. 1-8
Author(s):  
Mustafa Comoglu ◽  
Fatih Dede ◽  
Ezgi Coskun Yenigun ◽  
Canan Topcuoglu ◽  
Osman Inan ◽  
...  

<b><i>Introduction:</i></b> There is insufficient data on the role of the medium cutoff (MCO) membranes in the clearance of pro-inflammatory cytokines and oxidant radicals in patients with sepsis requiring hemodialysis. <b><i>Methods:</i></b> The study consisted of 38 septic patients who developed acute kidney injury (AKI) and who were scheduled to undergo 2 sessions of hemodialysis. Nineteen patients underwent their first dialysis session with the MCO membrane and 19 patients with the high-flux (HF) membrane. In the second session, the membranes were switched. Pro-inflammatory cytokine and oxidative marker levels were measured in blood samples obtained before and after both dialysis sessions. Reduction ratios were compared for the 2 types of hemodialysis membranes. <b><i>Results:</i></b> After the first session, there was a greater reduction in tumor necrosis factor (TNF)-α with the MCO membrane (28.2 ± 21.1 vs. 8.0 ± 6.6, <i>p</i> = 0.001). After the second session, there was a greater reduction in interleukin (IL)-6 (27.8 ± 26.5 vs. 5.9 ± 13.3, <i>p</i> = 0.003) and IL-1β (20.5 ± 21.1 vs. 4.0 ± 6.5, <i>p</i> = 0.004) with the MCO membrane. When the first and second sessions of all 38 patients were compared, the reductions in TNF-α, IL-6, and IL-1β were consistently greater for MCO than HF (<i>p</i> = 0.001, <i>p</i> = 0.006, <i>p</i> &#x3c; 0.001, respectively). The reductions in total antioxidant status, total oxidant status, and myeloperoxidase were not statistically different for the 2 types of dialysis membranes. <b><i>Conclusions:</i></b> MCO membrane was superior to HF membrane in the removal of cytokines in septic patients with AKI. However, a similar effect was not observed for oxidative stress markers.


2021 ◽  
Vol 1 (2) ◽  
pp. 121-134
Author(s):  
Pablo Molina ◽  
Julio Peiró ◽  
María A. Martínez-Gómez ◽  
Belén Vizcaíno ◽  
Cristina Esteller ◽  
...  

Dialytic clearance of p-cresyl sulfate (pCS) and other protein-bound toxins is limited by diffusive and convective therapies, and only a few studies have examined how to improve their removal by adsorptive membranes. This study tested the hypothesis that high-flux polymethylmethacrylate (PMMA) dialysis membranes with adsorptive capacity increase pCS removal compared to polysulfone membranes, in a postdilution on-line hemodiafiltration (OL-HDF) session. Thirty-five stable hemodialysis patients randomly completed a single study of 4 h OL-HDF with PMMA (BG2.1U, Toray®, Tokyo, Japan) and polysulfone (TS2.1, Toray®) membranes. The primary endpoint was serum pCS reduction ratios (RRs) obtained with each dialyzer. Secondary outcomes included RRs of other solutes such as β2-microglobulin, the convective volume obtained after each dialysis session, and the dialysis dose estimated by ionic dialysance (Kt) and urea kinetics (Kt/V). The RRs for pCS were higher with the PMMA membrane than those obtained with polysulfone membrane (88.9% vs. 58.9%; p < 0.001), whereas the β2-microglobulin RRs (67.5% vs. 81.0%; p < 0.001), Kt (60.2 ± 8.7 vs. 65.5 ± 9.4 L; p = 0.01), Kt/V (1.9 ± 0.4 vs. 2.0 ± 0.5; p = 0.03), and the convection volume (18.8 ± 2.8 vs. 30.3 ± 7.8 L/session; p < 0.001) were significantly higher with polysulfone membrane. In conclusion, pCS removal by OL-HDF was superior with high-flux PMMA membranes, appearing to be a good dialysis strategy for improving dialytic clearance of pCS, enabling an acceptable clearance of β2-microglobulin and small solutes.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Abdallah Guerraoui ◽  
Mathilde Prezelin-Reydit ◽  
Anne Kolko ◽  
Marie Lino-Daniel ◽  
Charlotte Dumas de Roque ◽  
...  

Abstract Background Kidney failure with replacement therapy and hemodialysis are associated with a decrease in quality of life (QOL). Self-reported QOL symptoms are not always prioritized by the medical team, potentially leading to conflicting priorities with patients. Electronic patient-reported outcome measures (ePROMs) allow physicians to better identify these symptoms. The objective was to describe the prevalence of symptoms self-reported by hemodialysis (HD) patients. Methods A multicenter cross-sectional study was conducted in three HD centers. Patients were included if they were 18 years old or over treated with HD for at least 3 months in a center. Data were collected by the patient via a self-administered ePROMs questionnaire. Data included patient characteristics, post-dialysis fatigue and intensity, recovery time after a session, perceived stress, impaired sleep the day before the dialysis session, current state of health and the change from the past year. A multivariate analysis was conducted to identify relations between symptoms. Results In total, we included 173 patients with a mean age of 66.2 years, a mean ± SD hemodialysis duration of 48.9 ± 58.02 months. The prevalence of fatigue was 72%. 66% had a high level of stress (level B or C). Recovery time was more than 6 h after a HD session for 25% of patients and 78% declared they had a better or unchanged health status than the previous year. Sleep disturbance was associated with cardiovascular comorbidities (OR 5.08 [95% CI, 1.56 to 16.59], p = 0.007). Conclusions Fatigue and stress were the main symptoms reported by HD patients. The patient’s care teams should better consider these symptoms.


2021 ◽  
pp. 112972982110528
Author(s):  
Emilie K Hansen ◽  
Kristine Lindhard ◽  
Ditte Hansen

Background: The arteriovenous fistula (AVF) is the preferred vascular access for hemodialysis (HD) treatment and preservation of a stable vascular access is crucial. Long term Far Infrared Radiation (FIR) has been found to increase access flow together with an enhanced maturation and patency of the AVF. The acute effects of FIR on access flow have been sparsely described and the results are contradictory, perhaps due to differences in measurement conditions and other factors of importance for access flow. Methods: Twenty patients in HD with an AVF were included. Each patient was randomized to receive either FIR (FIR group) or no FIR (control group). The acute changes in access flow were investigated in both groups on the second dialysis day of the week and during the first 1.5 h of the dialysis session. Concomitant changes in hemodynamic parameters of importance for access flow were also explored. Results: There was no significant change in access flow in the FIR group compared with the control group (median (Interquartile Range)) (−10 (−413.8; 21.3) ml/min vs −17.5 (−83.8; 76.3) ml/min, p = 0.58). There was no significant difference in any of the hemodynamic parameters between the FIR and the control group; cardiac output (−0.7 (−1.2; −0.2) l/min vs −0.4 (−0.9; 0.1) l/min, p = 0.58), cardiac index (−0.3 (−0.5; −0.1)) l/min/m2 vs −0.3 (−0.4; 0) l/min/m2, p = 0.68), mean arterial pressure (5.5 (−1.8; 8.4) mmHg vs 1.5 (−3; 6.3) mmHg, p = 0.35) and total peripheral resistance (2 (1.8; 3.4) mmHg × min/l vs 1 (−0.3; 3.1) mmHg × min/l, p = 0.12). Conclusion: In this trial, with a highly standardized set-up, one session of FIR did not result in any acute changes in access flow. This was not due to differences in the hemodynamic parameters between the groups.


Author(s):  
Lysleine Alves Deus ◽  
Hugo de Luca Corrêa ◽  
Rodrigo Vanerson Passos Neves ◽  
Andrea Lucena Reis ◽  
Fernando Sousa Honorato ◽  
...  

Background: Hemodialysis patients are suffering from depressive symptoms. Brain-derived neurotrophic factor (BDNF) levels are negatively associated with depressive symptoms and decrease during a single hemodialysis session. Resistance training (RT) might be an additional non-pharmacological tool to increase BDNF and promote mental health. Methods: Two randomized groups of hemodialysis patients: control (CTL, n = 76/F36; 66.33 ± 3.88 years) and RT (n = 81/F35; 67.27 ± 3.24 years). RT completed six months of training thrice a week under the supervision of strength and conditioning professional immediately before the dialysis session. Training loads were adjusted using the OMNI rating of perceived exertion. The total antioxidant capacity (TROLOX), glutathione (GSH), thiobarbituric acid reactive substance (TBARS), and BDNF levels were analyzed in serum samples. Quality of life (assessed through Medical Outcomes—SF36), and Beck Depression Inventory was applied. Results: RT improved handgrip strength (21.17 ± 4.38 vs. 27.17 ± 4.34; p = 0.001) but not for CTL (20.09 ± 5.19 vs. 19.75 ± 5.54; p = 0.001). Post-training, RT group had higher values as compared to CTL related to TROLOX (RT, 680.8 ± 225.2 vs. CTL, 589.5 ± 195.9; p = 0.001) and GSH (RT, 9.33 ± 2.09 vs. CTL,5.00 ± 2.96; p = 0.001). RT group had lower values of TBARS as compared to CTL at post-training (RT, 11.06 ± 2.95 vs. CTL, 13.66 ± 2.62; p = 0.001). BDNF increased for RT (11.66 ± 5.20 vs. 19.60 ± 7.23; p = 0.001), but decreased for CTL (14.40 ± 4.99 vs. 10.84 ± 5.94; p = 0.001). Quality of life and mental health increased (p = 0.001) for RT, but did not change for CTL (p = 0.001). BDNF levels were associated with emotional dimensions of SF36, depressive symptoms, and handgrip (p = 0.001). Conclusions: RT was effective as a non-pharmacological tool to increased BDNF levels, quality of life, temper the redox balance and decrease depressive symptoms intensity in hemodialysis patients.


2021 ◽  
Author(s):  
Ana Šavuk ◽  
Tomo Svaguša ◽  
Vladimir Trkulja ◽  
Andrea Radeljak ◽  
Diana Rudan ◽  
...  

Aim: Cardiac troponin I (cTnI) concentration stability during dialysis have not been fully elucidated. The aim is to evaluate the effect of a single dialysis session on plasma cTnI. Patients & methods: From 122 consecutive anuric adult patients (75 [61.5%] men, age 27–86 years, median 67) on chronic hemodialysis blood samples for cTnI measurement were taken before and after a dialysis. Results: Dialysis had no effect on high-flux membranes (geometric means ratio = 0.99, 0.94–1.05, df 119, t = -0.19, multiplicity adjusted p = 0.847), but cTnI levels were higher after dialysis in patients on low-flux membranes (geometric means ratio = 1.14, 1.02–1.27, df 119, t = 2.59, adjusted p = 0.021). Conclusion: Dialysis session using low-flux membranes might increase the plasma cTnI.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Tadashi Tomo ◽  
Maria Larkina ◽  
Ayumi Shintani ◽  
Tomonari Ogawa ◽  
Bruce M. Robinson ◽  
...  

Abstract Background The Japanese Society for Dialysis Therapy (JSDT) published in 2013 inaugural hemodialysis (HD) guidelines. Specific targets include 1.4 for single-pool Kt/V (spKt/V) with a minimum dose of 1.2, minimum dialysis session length of 4 hours, minimum blood flow rate (BFR) of 200 mL/min, fluid removal rate no more than 15 mL/kg/hr, and hemodiafiltration (HDF) therapy for certain identified symptoms. We evaluated the effect of these guidelines on actual practice in the years spanning 2005 – 2018. Methods Analyses were carried out to describe trends in the above HD prescription practices from December 2005 to April 2013 (before guideline publication) to August 2018 based on prevalent patient cross-sections from approximately 60 randomly selected HD facilities participating in the Japan Dialysis Outcomes and Practice Patterns Study. Results From April 2006 to August 2017 continual rises occurred in mean spKt/V (from 1.35 to 1.49), and percent of patients having spKt/V>1.2 (71% to 85%). Mean BFR increased with time from 198.3 mL/min (April 2006) to 218.4 mL/min (August 2017) , along with percent of patients with BFR >200 ml/min (65% to 85%). HDF use increased slightly from 6% (April 2006 and August 2009) to 8% by April 2013, but increased greatly thereafter to 23% by August 2017. In contrast, mean HD treatment time showed little change from 2006-2017, whereas mean UFR declined from 11.3 in 2006 to 8.4 mL/Kg/hour in 2017. Conclusions From 2006 – 2018 Japanese HD patients experienced marked improvement in reaching the spKt/V target specified by the 2013 JSDT guidelines. This may have been due to moderate increase in mean BFR even though mean HD session length did not change much. In addition, HDF use increased dramatically in this time period. Other HD delivery changes during this time, such as increased use of super high flux dialyzers, also merit study. While we cannot definitively conclude a causal relationship between the publication of the guidelines and the subsequent practice changes in Japan, those changes moved practice closer to the recommendations of the guidelines.


Sign in / Sign up

Export Citation Format

Share Document