Electrogram‐only guided approach to His bundle pacing with minimal fluoroscopy: A single‐center experience

2020 ◽  
Vol 31 (4) ◽  
pp. 805-812 ◽  
Author(s):  
Francesco Zanon ◽  
Lina Marcantoni ◽  
Marco Zuin ◽  
Gianni Pastore ◽  
Enrico Baracca ◽  
...  
Author(s):  
Stefanos Archontakis ◽  
Konstantinos Sideris ◽  
Ageliki Laina ◽  
Petros Arsenos ◽  
Dimitra Paraskevopoulou ◽  
...  

2020 ◽  
Vol 36 (4) ◽  
pp. 720-726
Author(s):  
Massimiliano Marini ◽  
Daniele Ravanelli ◽  
Marta Martin ◽  
Valentina Battisti ◽  
Silvia Quintarelli ◽  
...  

2020 ◽  
Vol 41 (7) ◽  
pp. 1425-1431
Author(s):  
Erick Jimenez ◽  
Nicholas Zaban ◽  
Nandita Sharma ◽  
Shanti Narasimhan ◽  
Chip Martin-Chafee ◽  
...  

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Oushan Tang ◽  
Haoliang Zhou ◽  
Caidi Yuan ◽  
Yinhong Cheng ◽  
Jin Lv

Abstract Background HB pacing is a promising approach to achieve physiological pacing, but its efficacy and long-term effects require further validation. In current study, we deemed to investigate the effect of the His bundle pacing (HBP) lead location on pacing parameters. Methods 2D echocardiography imaging was performed after successful implantation, according to which the patients were divided into groups A (whose His lead tips were at the atrial side) and B (whose His lead tips were at the ventricular side). The capture thresholds, sensing values, and H-V intervals between the two groups were compared. Results Thirteen patients were in group A and 16 patients were in group B. The average capture thresholds during, 1 month, and 1 year after operation were 1.20 ± 0.34, 0.69 ± 0.29, and 0.92 ± 0.80 V/0.5 ms for group A and 1.14 ± 0.43, 0.81 ± 0.39, and 0.98 ± 0.59 V/0.5 ms for group B, respectively. The difference between the two groups was not significant. The threshold values in both groups decreased significantly in 1 month and slightly increased in 1 year. The sensing values of group A were 1.87 ± 0.82, 1.95 ± 0.76, and 1.88 ± 0.75 mV, while those of group B were 4.53 ± 1.37, 4.69 ± 1.38, and 4.59 ± 1.42 mV. The difference among the three time points was not significant. However, the sensing values in group A were consistently significantly lower than those in group B. The HV interval in group A was significantly longer than that in group B. Conclusions The implantation site of HBP leads has a significant effect on sensing values for that His leads crossing the tricuspid annulus toward the ventricle are associated with higher sensing values, compared to a more proximal location. Meanwhile, lead location has no evident effect on capture thresholds that is improved significantly shortly after operation.


Sign in / Sign up

Export Citation Format

Share Document